ECO-PACTM 1 Single Phase Rectifier Bridge PSB 33F IdAV VRRM trr with fast Recovery Epitaxial Diode (FRED) + Preliminary Data Sheet VRSM VDSM (V) 400 600 VRRM Type VDRM (V) 400 PSB 33F/04 600 PSB 33F/06 ~A ~N K - Symbol Test Conditions I*dAV IdAVM IFSM TC = 85 °C, ∫ i dt 2 TVJ TVJM Tstg VISOL Maximum Ratings (per module) 44 A 90 A t = 10 ms (50 Hz), sine 110 A VR = 0 t = 8.3 ms (60 Hz), sine 120 A TVJ = TVJM t = 10 ms (50 Hz), sine 95 A VR = 0 t = 8.3 ms (60 Hz), sine 105 A TVJ = 45 °C t = 10 ms (50 Hz), sine 60 A²s VR = 0 t = 8.3 ms (60 Hz), sine 60 TVJ = TVJM t = 10 ms (50 Hz), sine VR = 0 t = 8.3 ms (60 Hz), sine -40... + 150 150 °C °C TVJ = 45 °C Package with DCB ceramic base plate A²s • UL registered, E 148688 45 A²s Applications 45 A²s -40... + 125 °C 50/60 Hz, RMS t = 1 min 3000 V∼ IISOL ≤ 1 mA 3600 V∼ 1.5 - 1.8 14 - 16 16 Nm lb.in. g t=1s Mounting torque Weight typ. Symbol Test Conditions IR VR = VRRM, TVJ = TVJM ≤ 0.5 mA VR = VRRM, TVJ = 25°C ≤ 0.1 mA IF = 15 A, ≤ 2.01 V 1.13 V 13 mΩ 1.6 0.4 1.9 K/W K/W K/W 0.48 K/W RthJK (M4) Characteristic Value TVJ = 25 °C For power-loss calculations only per diode; DC per module per diode; DC per module IRM IF=25A; -diF/dt=100A/µs; VR=100V Features • • • • • Md VF VTO rT RthJC = 44 A = 400 - 600 V = 35 ns typ. 4 A typ. 35 ns 11.2 9.7 50 mm mm m/s² • • • • Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering Supplies for DC power equipment Input and output rectifier for high frequency Battery DC power supplies Field supply for DC motors Advantages • • • • • Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability Low noise switching Small and light weight Package style and outline Dimensions in mm (1mm = 0.0394“) L=0.05 mH; TVJ= 100°C trr IF=1A; -diF/dt=100A/µs; VR=30V; TVJ= 25°C ds dA a Creeping distance on surface Creeping distance in air Max. allowable acceleration Data according to IEC 60747 refer to a single diode unless otherwise stated *- for resistive load at bridge output 2005 POWERSEM reserves the right to change limits, test conditions and dimensions POWERSEM GmbH, Walpersdorfer Str. 53 D - 91126 Schwabach Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20 ECO-PACTM 1 2005 POWERSEM reserves the right to change limits, test conditions and dimensions POWERSEM GmbH, Walpersdorfer Str. 53 D - 91126 Schwabach Phone: 09122 - 9764 - 0 FAX: 09122 - 9764 - 20