POWER-SYSTEMS PS-DA0151-02S

DC-AC INVERTER UNIT
PS-DA0151-02(S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for single lamps.
Optimized for Sharp: LQ057Q3DC12, 26th Sept. 2006
02
APPLICABLE LCD:
Lamp Voltage 690 Vrms
Lamp Current 5.0 mArms
Lamp Start Up Voltage 2.400 Vrms (Vin : 5 Vdc)
FEATURES :
Current balance circuit
Extra high starting Voltage
Dimming function over ext. PWM-signal
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
-30°C ~ +70°C (only LQ057Q3DC12)
-30°C ~ +85°C
95 %RH max
L x B x H 100 x 30 x 9 mm
SM02(8.0)B-BHS-1-TB (JST)
Pin 1
Pin 1
Unit : mm
Weight :15 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1-TB
Note
t=1m m
JST or equal
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.1, 6th October 2008
DC-AC INVERTER UNIT
PS-DA0151-02(S) (5 W SINGLE OUTPUT)
Input side CN1:
Pin No.
Symbols
Vin
CN 1-1
GND
CN 1-2
Ext. PWM
CN 1-3
N.C.
CN 1-4
N.C.
CN 1-5
(PRELIMINARY INFORMATION)
Output side CN2:
Pin No.
Symbols
VLOW
CN 2-1
N.C.
CN 2-2
VHIGH
CN 2-3
Ratings
4.75~5.25 Vdc
0 ~ 5 Vdc (L activ)
-
Ratings
(GND)
690Vrm s (5m Arm s )
-
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shotdown
Iout
Iout
Iin
F
Vopen
Ts d
Note 1 :
Note 2:
Vin (V)
Vbr (V)
5±0.25
5±0.25
5±0.25
5±0.25
5.0
5±0.25
0.0
5.0
0.0
0.0
0.0
0.0
Specification
Tu (°C)
-30
-30
-30
-30
-30
-30
~ +70
~ +70
~ +70
~ +70
~ +70
~ +70
Min.
Typ.
Max.
4.5
50
2.200
-
5.0
10
0.7
60
2.400
1.0
5.5
1.1
70
2.700
-
Unit
Note
m Arm s
%
Adc
kHz
Vrm s
s ec
Dut y 100 %
witho ut lo ad
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is normally at 250 Hz, and minimizes the interference disturbances of the vertical sync.
frequency.
TEST CIRCUIT :
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.1, 6th October 2008
DC-AC INVERTER UNIT
PS-DA0151-02(S) (5 W SINGLE OUTPUT)
(PRELIMINARY INFORMATION)
ORDER KEY :
PS-DA0151-02-x
With order of this innverter please give the following key:
-x Without Vrmt
-A: With Vrmt by CN1 Pin5
Examples:
PS-DA0151-01 (S)
Inverter without Vrmt
PS-DA0151-01-A (S)
Inverter with Vrmt
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstraße 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (3)
Version 1.0.1, 6th October 2008