POWER-SYSTEMS PS-M05S05-057

PS-M05S05-057 (S)
(Single Output 5 Watt)
DESCRIPTION :
This DC/AC Inverter is developed for alternative
Backlight Inverter to Endicot ERG.
The Inverter has PCB mounting pins.
The nominal input voltage is 5 VDC regulated.
Applicable LCD :
Displays:
Starting Voltage:
Lamp Current:
Sharp: LQ057Q3DC12
min. 1.350 Vrms
typ. 1 x 5 mArms (per lamp)
FEATURES :
Efficiency
PCB mounting:
Low noise:
Wide Input Voltage:
RoHS:
min. 75%
Pin diameter 1,62 mm
With voltage resonant circuit
5 VDC, must be regulated
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range 0°~ +60°C
Storage Temperature Range
-40 °~ + 85°C
Humidity
95 %RH max
Note: *
This inverter is usable for this display but the output current is not correct. The life time for
the CCFL lamp is shorter.
Power Systems - The Power Solution
Web:
Email Europe:
http://www.Power-Systems.de
[email protected]
All specifications are subject to change without notice
Address: Hauptstr. 48; 74360 Ilsfeld / Germany
Tel. Europe: + 49 / 7062 / 6759 - 6
Fax:
+ 49 / 7062 / 6759 - 800
Page ( 1 / 2 )
Version 1.1.1,
14th March 2007
PS-M05S05-057(S)
(Single Output 5 Watt)
Dimension:
32.0
7.62
17.7
8
7.62
6.10
15.24
2
1
27.94
39.70
6
Bottom View
3
5
4
PCB mounting pins 0.64 square
All dimensions in mm
10.16
20.23
5.60
Pinning:
Rating:
Pin Designation Table
Pin
Numbe r
Function
1
Input Positive
2
Input Negative
3
Output Common
4
Output 1
5
N.C.
6
N.C.
Rating
Minimum Typical Maximum Units
Ope ra ting Te mperature Ra nge
0
25
60
°C
Storage Te moerature Range
-20
25
85
°C
Input Voltage Range
4.5
5.0
5.5
Vdc
Input Current
1.2
Adc
Ope ra ting Fre quency
27
32
37
kHz
Lamp Starting Volta ge at 0°C
1350
Vrms
Lamp Voltage
690
Vrms
Efficie ncy
79
%
Output Current (Each La mp)
4.0
5.0
6.0
mArms
Dimminh Duty Cycle
10:1
1:1
Ration
Duty Cycle Input Voltage Ra nge
Vdc
Duty Cycle Frequency
Hz
Note:
Pin 5 and Pin 6 are not assembled.
Power Systems - The Power Solution
Web:
Email Europe:
http://www.Power-Systems.de
[email protected]
All specifications are subject to change without notice
Address: Hauptstr. 48; 74360 Ilsfeld / Germany
Tel. Europe: + 49 / 7062 / 6759 - 6
Fax:
+ 49 / 7062 / 6759 - 800
Page ( 2 / 2 )
Version 1.1.1,
14th March 2007