RALTRON SY12

FRAME PLL MODULE – SY12
Nov 8, 2002
n FEATURES
(PRELIMINARY)
•5V or 3.3 VOLT
•LOW JITTER FREQUENCY TRANSLATOR CRYSTAL BASED MODULE
MECHANICAL SPECIFICATION
.040
(1.02)
.250 MAX.
(6.35 MAX.)
.150
(3.81)
1.000
(25.4)
.050
(1.27)
SIDE VIEW
.700
(17.78)
.100 TYP.
(2.54)
9 10 11 12 13 14 15 16
MARKING
AREA
.055
(1.4)
.800
(20.32)
n
input frequency Ref. value
8 7
6 5
4 3
[13] RCLKOE (Recovered Clock Output Enable/Disable)
[14] N/C (No connect)
[15] GND (Ground)
[16] Vcc (Supply voltage)
2 1
DENOTES PIN 1.
TOP VIEW
PIN FUNCTIONS:
[1] CLKIN -The pin that takes the input reference freq.
[2] N/C (No connect)
[3] N/C (No connect)
[4] N/C (No connect)
[5] N/C (No connect)
[6] N/C (No connect)
[7] GND (Ground)
[8] N/C (No connect)
[9] OUT-(LVCMOS levels)
[10] OE (Output Enable/disable)
[11] LD (Lock Detector)- indicates lock mode or free-run
[12] RCLK (Recovered Clock) Output frequency divided to
BOTTOM VIEW
ELECTRICAL SPECIFICATION
PARAMETER
Input frequency, nom (Preselected)
Output frequency, nom (Preselected)
Tracking/Capture range, min.
Input/Output relationship, nom.
Loop Filter
Input waveform
Output waveform, max./min.
Supply voltage, nom.
Supply current, max.
Duty cycle
Rise- / fall time, typ.
Jitter generation, rms
Operating temperature
Storage temperature
Absolute voltage range
SYMBOL
fin
-
CONDITIONS
VALUE
8KHz~19.44MHz
UNIT
KHz
fout
-
**1MHz~155.52MHz
MHz
I/O
VI
VOH / VOL
**Over 0°C…+70°C, supply range, and 10 year aging
Internal to module
CMOS: Fin-1KHz~10MHz
Vcc=+3.3VDC (5V Optional), Ta=+25°C, load=15pF
ppm
°
V
Vcc
Is
DC
tr / tf
Jgen
Ta
T(stg)
Vcc(abs)
Vcc±5%
Vcc=+3.3VDC(5V Optional), Ta=+25°C, load=15pF
load=15pF/ @50%Vcc
20%~80% Vout, 80%~20% Vout
Non-destructive, DC
±32.0
0
2.97 / 0.33 for Vcc=3.3V
4.5/0.5 forVcc=5V
+3.3 or 5V
25.0
40…60
1.5
4.0
0…+70 or –40…+85
-40…+85
-0.5…+6.0
1/8/02 marketing-rfq, Synch Sy0012
**Below 19.44MHz specific output combinations available. Please consult factory for options available.
P/N selection
SY12- <freq./In (MHz)> - <freq/out(MHz)> - <Supply (V)> - <Oper. Temp. suffix>
|
Input Freq. In MHz _______|
|
|
Output Frequency in MHz__|
|
|
|
2 for 5V/4 for 3.3V______|
|
|
|
|
|
C for 0°C..+70°C
X for -40°C..+85°C_________|
Examples;
1. SY12-0.008-19.44-2-X; – Input – 8KHz/Output – 19.44MHz/5V supply/-40°C..+85°C
SY12-0.512-38.88-4-C; - Input-512KHz/ Output 38.88MHz/3.3V supply/ 0°C..70°C
RALTRON ELECTRONICS CORP.
10651 N.W . 19
th
St
Miami, Florida 33172
U.S.A.
phone: +001(305) 593-6033 fax: +001(305)594-3973 e-mail: [email protected] internet: http:/www.raltron.com
V
mA
%
ns
ps
°C
°C
V
FRAME PLL MODULE – SY12
Block Diagram
RCLKOE
LD
RCLK
CLK IN
Out
DPLL
E/D
PIN FUNCTIONS:
[1] CLKIN -The pin that takes the input reference freq.
[2] N/C (No connect)
[3] N/C (No connect)
[4] N/C (No connect)
[5] N/C (No connect)
[6] N/C (No connect)
[7] GND (Ground)
[8] N/C (No connect)
[9] OUT-(LVCMOS levels)
[10] OE (Output Enable/disable)
[11] LD (Lock Detector)- indicates lock mode or free-run
[12] RCLK (Recovered Clock) Output frequency divided to
[13] RCLKOE (Recovered Clock Output Enable/Disable)
[14] N/C (No connect)
[15] GND (Ground)
[16] Vcc (Supply voltage)
RALTRON ELECTRONICS CORP.
input frequency Ref. value
10651 N.W . 19
th
St
Miami, Florida 33172
U.S.A.
phone: +001(305) 593-6033 fax: +001(305)594-3973 e-mail: [email protected] internet: http:/www.raltron.com