RECTRON SE4L

SE1L
THRU
SE4L
SURFACE MOUNT SUPER FAST RECTIFIER
VOLTAGE RANGE 50 to 200 Volts CURRENT 1.0 Ampere
FEATURES
*
*
*
*
*
*
*
High reliability
Low leakage
Low forward voltage
High current capability
Super fast switching speed
High surge capability
Good for switching mode circuit
SOD-123FL
.114 (2.9)
.106 (2.7)
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.016 gram
.035 (0.90)
.077 (1.95)
.028 (0.70)
.069 (1.75)
.008 (0.20)
.039 (1.00)
.035 (0.90)
.150 (3.8)
.142 (3.6)
.052 (1.32)
.050 (1.28)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
.033 (0.85)
Single phase, half wave, 60 Hz, resistive or inductive load.
.030 (0.75)
.033 (0.85)
.044 (1.12)
.030 (0.75)
.043 (1.08)
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
RATINGS
SYMBOL
SE1L
SE2L
SE3L
SE4L
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
150
200
Volts
Maximum RMS Volts
VRMS
35
70
105
140
Volts
VDC
50
100
150
200
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Current
at T A = 55 oC
IO
Peak Forward Surge Current I FM (surge):8.3 ms single half
sine-wave superimposed on rated load (JEDEC method)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
1.0
Amps
I FSM
25
Amps
CJ
20
pF
T J , T STG
-55 to + 150
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
Maximum Forward Voltage at 1.0 A DC
SYMBOL
VF
Maximum DC Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A =100 o C
Maximum Reverse Recovery Time (Note 1)
NOTES : 1. Test Conditions: IF=0.5A, I R=-1.0A, IRR=-0.25A.
2. Measured at 1 MHZ and applied reverse voltage of 4.0 volts.
3.“Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
IR
trr
SE1L
SE2L
SE3L
0.95
5.0
100
35
SE4L
UNITS
Volts
uAmps
nSec
2006-3
REV:O
RATING AND CHARACTERISTIC CURVES ( SE1L THRU SE4L )
FIG. 1 - TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
10
NONINDUCTIVE
+0.5A
(-)
D.U.T
(+)
25 Vdc
(approx)
(-)
0
PULSE
GENERATOR
(NOTE 2)
1
NONINDUCTIVE
OSCILLOSCOPE
(NOTE 1)
-0.25A
(+)
-1.0A
NOTES:1 Rise Time = 7ns max. Input Impedance =
1cm
1 megohm. 22pF.
2. Rise Time = 10ns max. Source Impedance =
50 ohms.
SET TIME BASE FOR
10 ns/cm
FIG. 3 - TYPICAL REVERSE CHARACTERISTICS
100
TJ = 100
10
TJ = 25
.1
0
20
40
60
80
100
120
20
15
10
5
0
1
2
5
10
20
50
NUMBER OF CYCLES AT 60Hz
100
0 25 50 75 100 125 150 175
AMBIENT TEMPERATURE (
TJ = 25
Pulse Width = 300uS
1% Duty Cycle
.01
0
.2
.4
.6
.8
1.0
1.2
1.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG. 6 - TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE, (pF)
PEAK FORWARD SURGE CURRENT, (A)
25
0
.1
FIG. 5 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
8.3ms Single Half Sine-Wave
(JEDEC Method)
1.0
1.0
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
30
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
CHARACTERISTICS
10
.001
140
35
2.0
FIG. 4 - TYPICAL INSTANTANEOUS FORWARD
INSTANTANEOUS FORWARD CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (uA)
1000
1.0
FIG. 2 - TYPICAL FORWARD
CURRENT DERATING CURVE
trr
AVERAGE FORWARD CURENT, (A)
50
NONINDUCTIVE
200
100
60
40
20
10
6
4
TJ = 25
2
1
.1
.2
.4
1.0
2
4
10
20 40 100
REVERSE VOLTAGE, ( V )
)
Mounting Pad Layout
.052
(1.32)REF
.035
(0.9)REF
.033
(0.85)REF
.044
(1.12)REF
.150
(3.8)REF
Dimensions in inches and (millimeters)
.033
(0.85)REF
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.