RECTRON 1E2

1E1
RECTRON
THRU
SEMICONDUCTOR
TECHNICAL SPECIFICATION
1E4
GLASS PASSIVATED SUPER FAST RECTIFIER
VOLTAGE RANGE 50 to 200 Volts CURRENT 1.0 Ampere
FEATURES
*
*
*
*
*
*
*
High reliability
Low leakage
Low forward voltage
High current capability
Super fast switching speed
High surge capability
Good for switching mode circuit
R-1
MECHANICAL DATA
*
*
*
*
*
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.19 gram
.025 (0.65)
DIA.
.021 (0.55)
.787 (20.0)
MIN.
.126 (3.2)
.106 (2.7)
.102 (2.6)
DIA.
.091 (2.3)
.787 (20.0)
MIN.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At TA = 25oC unless otherwise noted)
SYMBOL
1E1
1E2
1E3
1E4
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
150
200
Volts
Maximum RMS Volts
VRMS
35
70
105
140
Volts
VDC
50
100
150
200
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Current
at T A = 25 oC
Peak Forward Surge Current I FM (surge):8.3 ms single half
sine-wave superimposed on rated load (JEDEC method)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range
IO
1.0
Amps
I FSM
25
Amps
CJ
15
pF
T J , T STG
-55 to + 150
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
Maximum Forward Voltage at 1.0A DC
SYMBOL
VF
Maximum DC Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A =150 o C
Maximum Reverse Recovery Time (Note 1)
NOTES : 1. Test Conditions: IF=0.5A, IR=-1.0A, IRR=-0.25A.
2. Measured at 1 MHZ and applied reverse voltage of 4.0 volts.
3. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
IR
1E1
1E2
1E3
0.95
5.0
1E4
UNITS
Volts
uAmps
50
trr
35
nSec
2005-1
REV:A
RATING AND CHARACTERISTIC CURVES ( 1E1 THRU 1E4 )
FIG. 1 - TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
10
NONINDUCTIVE
FIG. 2 - TYPICAL FORWARD
CURRENT DERATING CURVE
trr
AVERAGE FORWARD CURENT, (A)
50
NONINDUCTIVE
+0.5A
(-)
D.U.T
(+)
25 Vdc
(approx)
(-)
0
PULSE
GENERATOR
(NOTE 2)
1
NONINDUCTIVE
OSCILLOSCOPE
(NOTE 1)
-0.25A
(+)
-1.0A
1cm
NOTES:1 Rise Time = 7ns max. Input Impedance =
SET TIME BASE FOR
10 ns/cm
1 megohm. 22pF.
2. Rise Time = 10ns max. Source Impedance =
50 ohms.
FIG. 3 - TYPICAL REVERSE CHARACTERISTICS
TJ = 150
10
TJ = 100
1.0
TJ = 25
.1
.01
1.0
0
0 25 50 75 100 125 150 175
AMBIENT TEMPERATURE (
CHARACTERISTICS
10
1.0
TJ = 25
.1
Pulse Width = 300uS
1% Duty Cycle
.01
.001
0
20
40
60
80
100
120
0
140
JUNCTION CAPACITANCE, (pF)
30
8.3ms Single Half Sine-Wave
(JEDEC Method)
25
20
15
10
5
0
1
2
5
10
20
50
NUMBER OF CYCLES AT 60Hz
100
.4
.6
.8
1.0
1.2
1.4
FIG. 6 - TYPICAL JUNCTION CAPACITANCE
FIG. 5 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
35
.2
INSTANTANEOUS FORWARD VOLTAGE, (V)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
PEAK FORWARD SURGE CURRENT, (A)
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
FIG. 4 - TYPICAL INSTANTANEOUS FORWARD
INSTANTANEOUS FORWARD CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (uA)
100
2.0
200
100
60
40
20
10
6
4
TJ = 25
2
1
.1
.2
.4
1.0
2
4
10
20 40 100
REVERSE VOLTAGE, ( V )
RECTRON
)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
RECTRON