SOURCE SP-GB-LX-TNA

10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Features
• Data Rate 1.062 to 1.25 Gb/s
• Single 3.3V Supply
• 10km Reach
• 13dB Typical Link Budget
• Commercial, Reduced and Industrial Temp. Operation
• 1310nm FP Laser
• Fibre Channel 100-SM-LC-L Compliant
• Gigabit Ethernet IEEE 802.3ah Compliant
• SFP MSA SFF-8074i Compliant
• Telcordia GR-468 Compliant
• Digital Diagnostic SFF-8472 Compliant
• Color code Bail Latch : Blue
• RoHS compliant
General Operation
Symbol
Min.
Typ.
Max.
Supply Voltage
Parameter
Vcc
3.135
3.3
3.465
Unit
V
Total Current
ICC
-
-
300
mA
Power Supply Rejectiona
PSR
100
-
-
mVp-p
Operating Case Temperature (-CxA)
Topr
-5
-
70
ºC
Operating Case Temperature (-RxA)
Topr
-20
-
85
ºC
Operating Case Temperature (-TxA)
Topr
-40
-
85
ºC
Storage Temperature
Tstg
-40
-
85
ºC
Data Rate GbE
DR
-
1250
-
Mbps
Data Rate FC
DR
-
1062.5
-
Mbps
Symbol
Min
Typical
Max
Unit
Optical Power
Pop
-9
-5
-3
dBm
Average Launch Power (Tx:Off)
Poff
-
-
-30
dBm
Extinction Ratio
ER
9
-
-
dB
a) 20Hz to 155MHz
Transmitter Specifications (Optical)
Parameter
Eye Mask
IEEE 802.3ah compliant
Total Jitter
TJ
-
-
200
ps
Optical Rise Timeb
tr
-
-
260
ps
b
Optical Fall Time
tf
-
-
260
ps
Mean Wavelength
λ
1270
1310
1355
nm
Spectral Width (RMS)
∆λ
Relative Intensity Noise
RIN
IEEE 802.3ah 1000BASE-LX10 Compliant
-
-
-120
dB/Hz
b) 20%-80% values
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS833-Jul1008
Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Transmitter Specifications (Electrical)
Parameter
Symbol
Min
Typical
Max
Unit
Rin
80
100
120
Ω
Vin, p-p
250
-
1200
mV
Vfault
2
-
Vcc
V
Vnormal
Vd
Vee
-
Vee + 0.5
V
TxDisable_Disable
2
-
Vcc
V
TxDisable_Enable
Ven
Vee
-
Vee + 0.8
V
Parameter
Symbol
Min
Typical
Max
Unit
Receiver Power Lowc
-
-24
-22
dBm
Receiver Power Highc
Rsens,low
Rsens,high
-3
0
-
dBm
Damage Threshold for Receiver
Pin, damage
6
-
-
dBm
λ
1270
-
1355
nm
RX_r
-
-
-12
dB
LOS Assert
-
-38
-
-
dBm
LOS De-Assert
-
-
-
-22
dBm
LOS Hysteresis
-
0.5
-
-
dB
Input Differential Impedence
PECL Single Ended Data Input Swing
TxFault_Fault
TxFault_Normal
Receiver Specifications (Optical)
Wavelengthd
Maximum Reflectance of Receiver
-12,
27-1,
PRBS of
c) Measured at BER of 10
d) Operational over 1200-1625nm range
at eye center
Receiver Specifications (Electrical)
Parameter
Symbol
Min
Typical
Max
Unit
PECL Single-Ended Data Output Swing
Vout,p-p
185
-
800
mV
Data Output Rise Time
tr
-
-
260
ps
Data Output Fall Time
tf
-
-
260
ps
Timing and Electrical
Symbol
Min
Typical
Max
Unit
Tx Disable Negate Time
Parameter
t_on
-
-
1
ms
Tx Disable Assert Time
t_off
-
-
10
µs
Time to Initialize, Including Reset of Tx Fault
t_init
-
-
300
ms
Tx Fault Assert Time
t_fault
-
-
100
µs
Tx Disable to Reset
t_reset
10
-
-
µs
t_loss_on
-
-
100
µs
t_loss_off
f_serial_clock
Rx_LOSH
2
-
100
100
Vcc
µs
KHz
V
LOS Assert Time
LOS De-assert Time
Serial ID Clock Rate
RX_LOS Voltage (high)
RX_LOS Voltage (low)
RX_LOSL
-
-
0.8
V
LOS Output Voltage-Fault
VLOS fault
2
-
Vcc
V
VLOS normal
Vee
-
Vee + 0.5
V
MOD_DEF (0:2)-High
Vh
2
-
V
MOD_DEF (0:2)-Low
VI
Vee
-
Vcc
Vee + 0.5
LOS Output Voltage-Normal
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
V
LUMNDS833-Jul1008
Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Diagnostics
Parameter
Range
Accuracy
Unit
Calibration
Formula
Temperature (-CDA)
-5 to 70
±3
ºC
External
Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset
Temperature (-RDA)
-20 to 85
±3
ºC
External
Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset
Temperature (-TDA)
-40 to 85
±3
ºC
External
Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset
Voltage
0 to Vcc
0.1
V
External
V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset
Bias Current
0 to 120
5
mA
External
I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset
Tx Power
-9 to -3
±3dB
dBm
External
Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned
integer)+Tx_PWRoffset
Rx Power
-22 to -3
±3dB
dBm
External
Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Pinout Definitions
Pin
Function
Notes
1
VeeT
TX GND
2
TX_FAULT
Open Collector
3
TX_DISABLE
Internally Pulled High
4
MOD_DEF2
Serial Data Input
5
MOD_DEF1
Serial Clock Input
6
MOD_DEF0
Internally Grounded
7
NC
Not Connected
8
LOS
Open Collector
9
VeeR
RX Ground
10
VeeR
RX Ground
11
VeeR
RX Ground
12
RXD-
RX Data Negative
13
RXD+
RX Data Positive
14
VeeR
RX GND
15
VCCR
RX Power
16
VCCT
TX Power
17
VeeT
TX GND
18
TXD+
TX Data Positive
19
TXD-
TX Data Negative
20
VeeT
TX GND
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS833-Jul1008
Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
EEPROM Serial ID
Name of Field
Vendor Name
Vendor OUI
Vendor P/N
LUMINENTOIC.COM
Discription of Field
SFP Vendor name (ASCII)
IEEE vendor OUI code for LuminentOIC Inc.
Part number in ASCII, e.g.
SP-GB-LX-CDA
Address
Hex
20
4C
L
21
55
U
22
4D
M
23
49
I
24
4E
N
25
45
E
26
4E
N
27
54
T
28
4F
O
29
49
I
30
43
C
37
00
38
06
39
B5
40
53
41
50
P
42
47
G
43
42
B
44
4C
L
45
58
X
46
43
C
47
44
D
48
41
A
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
ASCII
S
LUMNDS833-Jul1008
Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Outline Drawing
Units in mm(inches)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS833-Jul1008
Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Suggested Transceiver interface
1�H
Vcc
10�F
1�H
0.1�F
VCCT
.01�F
Protocol IC
R1
LuminentOIC
SFP
10K�
TX_DISABLE
TX_DISABLE
TX_FAULT
TX_FAULT
TD +
SerDes
Laser Driver
.01�F
100�
TD VEET
.01�F
VCCR
10�F
0.1�F
RD +
Receiver Amplifier
.01�F
100�
RD -
RX_LOS
RX_LOS
Vcc
R
VEER
1
R1
R1
.01�F
EEPROM
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10K�
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS833-Jul1008
Rev A.7
10Km Gigabit Ethernet SFP Transceiver
SP-GB-LX
Ordering Information
Available Options:
SP-GB-LX-CDA
SP-GB-LX-TDA
SP-GB-LX-RDA
SP-GB-LX-CNA
SP-GB-LX-TNA
SP-GB-LX-RNA
Part numbering Definition:
SP - GB - LX - Temperature Diagnostic
Revision
• SP = Small Form Pluggable
GB = 1.25Gbps
LX = IEEE 802.3 LX Interface
• Operating Temperature
C = Commercial temperature (-5 to 70ºC)
R = Reduced Industrial (-20 to 85ºC)
T = Industrial temperature (-40 to 85ºC)
• Diagnostic
D = Digital Diagnostic (SFF-8472)
N = No Diagnostic
• Design Revision
A = RoHS compliant
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS833-Jul1008
Rev A.7