SOURCE SPS-53-FE-BX-TDC

SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Features
• Compliant with OC3/STM-1, IEEE 802.3ah, 100BASE-BX10
• Simplex SC Connector
• Digital Diagnostic SFF-8472 Compliant
• SFP MSA SFF-8074i Compliant
• 14 dB Minimum Power Budget
• 10 km Typical reach
• Commercial and Industrial Temperature Available
• Single 3.3V Supply
• 1530 nm FP Laser
• Telcordia GR-468 Compliant
• Color Coded Yellow Bail Latch
• RoHS-6/6 compliant (lead free soldering) (-xxC)
General Operation
Symbol
Min.
Typ.
Max.
Supply Voltage
Parameter
Vcc
3.135
3.3
3.465
V
Total Current
ICC
-
-
300
mA
Power Supply Noise Rejection
Unit
100
-
-
mVp-p
Operating Temerature (-Cxx)
Topr
-5
-
70
ºC
Operating Temerature (-Txx)
Topr
-40
-
85
ºC
Storage Temperature
Tstg
-40
-
85
ºC
Data Rate
DR
10
-
155
Mbps
Transmitter Specifications (Optical)
Parameter
Symbol
Min
Typical
Max
Unit
Optical power
Pop
-14
-11
-8
dBm
Optical crosstalk
XT
-
-45
-40
dB
Average Launch power of off Tx
Extinction Ratio
Poff
-
-
-45
dBm
ER
6.6
-
-
dB
Eye Mask
IEEE 802.3 and SONET/SDH Compliant
Optical Rise time (20% to 80% values)
tr
Optical Fall time (20% to 80% values)
tf
-
-
2
ns
Mean Wavelength
λ
1480
1530
1580
nm
Spectral Width (RMS)
Relative Intensity Noise
Optical Return Loss Tolerance
LUMINENTOIC.COM
-
-
2
ns
σ
2
-
4
nm
RIN
-
-
-120
dB/Hz
ORLT
-
-
12
dB
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
1
LUMNDS1578-Jan1107
Rev A.3
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Transmitter Specifications (Electrical)
Parameter
Symbol
Min
Typical
Max
Unit
Rin
80
100
120
Ω
Vin, p-p
250
-
1200
mV
Vfault
2
-
Vcc
V
Vnormal
Vd
Vee
-
Vee + 0.5
V
TxDisable_Disable
2
-
Vcc
V
TxDisable_Enable
Ven
Vee
-
Vee + 0.8
V
Input Differential Impedence
PECL Single Ended data input swing
TxFault_Fault
TxFault_Normal
Receiver Specifications (Optical)
Parameter
Symbol
Min
Typical
Max
Unit
Receiver Power Lowa
Rsens,low
-
-30
-28.2
dBm
Receiver Power High
Rsens,high
-8
-
-
dBm
Damage Threshold for Receiver
Pin, damage
4
-
-
dBm
Wavelength
λ
1260
-
1360
nm
LOS Assert
-
-45
-
-
dBm
LOS De-assert
-
-
-
-28.2
dBm
LOS hysteresis
-
1
-
-
dB
Parameter
Symbol
Min
Typical
Max
Unit
CML Single ended data output swing
Vout,p-p
185
-
800
mV
tr
-
-
2
ns
tf
-
-
2
ns
a) at
10-12
BER, PRBS
27-1
Receiver Specifications (Electrical)
Data output rise time
Data output fall time
Timing and Electrical
Parameter
Symbol
Min
Typical
Max
Unit
t_on
-
-
25
ms
Tx Disable assert time
t_off
-
-
10
µs
Time to initialize, including reset of Tx fault
t_init
-
-
300
ms
Tx Disable Negate time
Tx fault Assert time
t_fault
-
-
100
µs
Tx Disable to reset
t_reset
10
-
-
µs
t_loss_on
-
-
1000
µs
t_loss_off
f_serial_clock
Rx_LOSH
2
-
100
100
-
µs
KHz
V
LOS Assert time
LOS De-assert time
Serial ID Clock Rate
RX_LOS Voltage (high)
RX_LOS Voltage (low)
RX_LOSL
-
-
0.8
V
LOS output voltage-Fault
VLOS fault
2
-
Vcc
V
VLOS normal
Vee
-
Vee + 0.5
V
Vcc
Vee + 0.5
V
LOS output voltage-Normal
MOD_DEF (0:2)-High
Vh
2
-
MOD_DEF (0:2)-Low
VI
Vee
-
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
V
LUMNDS1578-Jan1107
Rev A.3
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Diagnostics
Parameter
Range
Accuracy
Unit
Calibration
Bit Value
Formula
Temperature (CDC)
-5 to 70
±3
ºC
Internal
1/256 C
Tc(C) = Tad(16 bit signed twos complement)/256
Temperature (TDC)
-40 to 85
±3
ºC
Internal
1/256 C
Tc(C) = Tad(16 bit signed twos complement)/256
Voltage
0 to Vcc
.1
V
Internal
100µV
V(Volts) = Vad(16 bit unsigned integer)*0.1
Bias Current
0 to 120
5
mA
External
-
I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset
Tx Power
-14 to -8
±3
dBm
External
-
Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned
integer)+Tx_PWRoffset
Rx Power
-28.2 to -8
±3
dBm
External
-
Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Pinout Definitions
Pin
Function
Notes
1
VeeT
TX GND
2
TX_FAULT
Open Collector
3
TX_DISABLE
Internally Pulled High
4
MOD_DEF2
Serial Data Input
5
MOD_DEF1
Serial Clock Input
6
MOD_DEF0
Internally Grounded
7
NC
Not Connected
8
LOS
Open Collector
9
VeeR
RX Ground
10
VeeR
RX Ground
11
VeeR
RX Ground
12
RXD-
RX Data Negative
13
RXD+
RX Data Positive
14
VeeR
RX GND
15
VCCR
RX Power
16
VCCT
TX Power
17
VeeT
TX GND
18
TXD+
TX Data Positive
19
TXD-
TX Data Negative
20
VeeT
TX GND
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
3
LUMNDS1578-Jan1107
Rev A.3
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
EEPROM Serial ID
Name of Field
Vendor Name
Vendor OUI
Vendor PN
LUMINENTOIC.COM
Discription of Field
SFP Vendor name (ASCII)
IEEE vendor OUI code for LuminentOIC
Part number in ASCII, e.g.
SPS-53-FE-BX-CDC
Address
Hex
20
4C
L
21
55
U
22
40
M
23
49
I
24
4E
N
25
45
E
26
4E
N
27
54
T
28
4F
O
29
49
I
30
43
C
37
00
38
06
39
B5
40
53
S
41
50
P
42
53
S
43
35
5
44
33
3
45
46
F
46
45
E
49
42
50
58
B
X
51
43
C
52
44
D
53
43
C
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
4
ASCII
LUMNDS1578-Jan1107
Rev A.3
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
SC Connector Mechanical
Units in mm(inches)
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
5
LUMNDS1578-Jan1107
Rev A.3
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Suggested Transceiver Interface
1�H
Vcc
10�F
1�H
0.1�F
VCCT
.01�F
Protocol IC
R1
LuminentOIC
SFP
10K�
TX_DISABLE
TX_DISABLE
TX_FAULT
TX_FAULT
TD +
SerDes
Laser Driver
.01�F
100�
TD VEET
.01�F
VCCR
10�F
0.1�F
RD +
Receiver Amplifier
.01�F
100�
RD -
RX_LOS
RX_LOS
Vcc
R
VEER
1
R1
R1
.01�F
EEPROM
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10K�
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
6
LUMNDS1578-Jan1107
Rev A.3
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Ordering Information
Available Options: SPS-53-FE-BX-CDC
SPS-53-FE-BX-TDC
SPS-53-FE-BX-CNC
SPS-53-FE-BX-TNC
Part numbering Definition:
SPS - 53 - FE - BX -
Temperature Diagnostic Revision
• SPS = SC connector
• Wavelength
53 = Tx 1530nm/Rx 1310nm
• Data Rate
FE = Fast Ethernet (100Mbps)
• Standard
BX = 100BASE-BX
• Operatating Temperature
C = Commercial temperature (-5 to 70ºC)
T = Industrial temperature (-40 to 85ºC)
• D = Digital Diagnostic (SFF-8472)
N = No Diagnostic
• Design Revision
C = RoHS-6/6 compliant (lead free soldering)
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
7
LUMNDS1578-Jan1107
Rev A.3