SFP Bi-Directional Transceiver SPS-53-FE-BX-xxC Features • Compliant with OC3/STM-1, IEEE 802.3ah, 100BASE-BX10 • Simplex SC Connector • Digital Diagnostic SFF-8472 Compliant • SFP MSA SFF-8074i Compliant • 14 dB Minimum Power Budget • 10 km Typical reach • Commercial and Industrial Temperature Available • Single 3.3V Supply • 1530 nm FP Laser • Telcordia GR-468 Compliant • Color Coded Yellow Bail Latch • RoHS-6/6 compliant (lead free soldering) (-xxC) General Operation Symbol Min. Typ. Max. Supply Voltage Parameter Vcc 3.135 3.3 3.465 V Total Current ICC - - 300 mA Power Supply Noise Rejection Unit 100 - - mVp-p Operating Temerature (-Cxx) Topr -5 - 70 ºC Operating Temerature (-Txx) Topr -40 - 85 ºC Storage Temperature Tstg -40 - 85 ºC Data Rate DR 10 - 155 Mbps Transmitter Specifications (Optical) Parameter Symbol Min Typical Max Unit Optical power Pop -14 -11 -8 dBm Optical crosstalk XT - -45 -40 dB Average Launch power of off Tx Extinction Ratio Poff - - -45 dBm ER 6.6 - - dB Eye Mask IEEE 802.3 and SONET/SDH Compliant Optical Rise time (20% to 80% values) tr Optical Fall time (20% to 80% values) tf - - 2 ns Mean Wavelength λ 1480 1530 1580 nm Spectral Width (RMS) Relative Intensity Noise Optical Return Loss Tolerance LUMINENTOIC.COM - - 2 ns σ 2 - 4 nm RIN - - -120 dB/Hz ORLT - - 12 dB 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS1578-Jan1107 Rev A.3 SFP Bi-Directional Transceiver SPS-53-FE-BX-xxC Transmitter Specifications (Electrical) Parameter Symbol Min Typical Max Unit Rin 80 100 120 Ω Vin, p-p 250 - 1200 mV Vfault 2 - Vcc V Vnormal Vd Vee - Vee + 0.5 V TxDisable_Disable 2 - Vcc V TxDisable_Enable Ven Vee - Vee + 0.8 V Input Differential Impedence PECL Single Ended data input swing TxFault_Fault TxFault_Normal Receiver Specifications (Optical) Parameter Symbol Min Typical Max Unit Receiver Power Lowa Rsens,low - -30 -28.2 dBm Receiver Power High Rsens,high -8 - - dBm Damage Threshold for Receiver Pin, damage 4 - - dBm Wavelength λ 1260 - 1360 nm LOS Assert - -45 - - dBm LOS De-assert - - - -28.2 dBm LOS hysteresis - 1 - - dB Parameter Symbol Min Typical Max Unit CML Single ended data output swing Vout,p-p 185 - 800 mV tr - - 2 ns tf - - 2 ns a) at 10-12 BER, PRBS 27-1 Receiver Specifications (Electrical) Data output rise time Data output fall time Timing and Electrical Parameter Symbol Min Typical Max Unit t_on - - 25 ms Tx Disable assert time t_off - - 10 µs Time to initialize, including reset of Tx fault t_init - - 300 ms Tx Disable Negate time Tx fault Assert time t_fault - - 100 µs Tx Disable to reset t_reset 10 - - µs t_loss_on - - 1000 µs t_loss_off f_serial_clock Rx_LOSH 2 - 100 100 - µs KHz V LOS Assert time LOS De-assert time Serial ID Clock Rate RX_LOS Voltage (high) RX_LOS Voltage (low) RX_LOSL - - 0.8 V LOS output voltage-Fault VLOS fault 2 - Vcc V VLOS normal Vee - Vee + 0.5 V Vcc Vee + 0.5 V LOS output voltage-Normal MOD_DEF (0:2)-High Vh 2 - MOD_DEF (0:2)-Low VI Vee - LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 V LUMNDS1578-Jan1107 Rev A.3 SFP Bi-Directional Transceiver SPS-53-FE-BX-xxC Diagnostics Parameter Range Accuracy Unit Calibration Bit Value Formula Temperature (CDC) -5 to 70 ±3 ºC Internal 1/256 C Tc(C) = Tad(16 bit signed twos complement)/256 Temperature (TDC) -40 to 85 ±3 ºC Internal 1/256 C Tc(C) = Tad(16 bit signed twos complement)/256 Voltage 0 to Vcc .1 V Internal 100µV V(Volts) = Vad(16 bit unsigned integer)*0.1 Bias Current 0 to 120 5 mA External - I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset Tx Power -14 to -8 ±3 dBm External - Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned integer)+Tx_PWRoffset Rx Power -28.2 to -8 ±3 dBm External - Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4 Pinout Definitions Pin Function Notes 1 VeeT TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VCCR RX Power 16 VCCT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS1578-Jan1107 Rev A.3 SFP Bi-Directional Transceiver SPS-53-FE-BX-xxC EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor PN LUMINENTOIC.COM Discription of Field SFP Vendor name (ASCII) IEEE vendor OUI code for LuminentOIC Part number in ASCII, e.g. SPS-53-FE-BX-CDC Address Hex 20 4C L 21 55 U 22 40 M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 S 41 50 P 42 53 S 43 35 5 44 33 3 45 46 F 46 45 E 49 42 50 58 B X 51 43 C 52 44 D 53 43 C 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 ASCII LUMNDS1578-Jan1107 Rev A.3 SFP Bi-Directional Transceiver SPS-53-FE-BX-xxC SC Connector Mechanical Units in mm(inches) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS1578-Jan1107 Rev A.3 SFP Bi-Directional Transceiver SPS-53-FE-BX-xxC Suggested Transceiver Interface 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC R1 LuminentOIC SFP 10K� TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS1578-Jan1107 Rev A.3 SFP Bi-Directional Transceiver SPS-53-FE-BX-xxC Ordering Information Available Options: SPS-53-FE-BX-CDC SPS-53-FE-BX-TDC SPS-53-FE-BX-CNC SPS-53-FE-BX-TNC Part numbering Definition: SPS - 53 - FE - BX - Temperature Diagnostic Revision • SPS = SC connector • Wavelength 53 = Tx 1530nm/Rx 1310nm • Data Rate FE = Fast Ethernet (100Mbps) • Standard BX = 100BASE-BX • Operatating Temperature C = Commercial temperature (-5 to 70ºC) T = Industrial temperature (-40 to 85ºC) • D = Digital Diagnostic (SFF-8472) N = No Diagnostic • Design Revision C = RoHS-6/6 compliant (lead free soldering) Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS1578-Jan1107 Rev A.3