Double Balanced Mixer Model MM134xG-1 Ultra-Broadband RF 1.5 to 26.5 GHz (1) Electrical Specifications : Specifications Conditions Parameter SSB Conversion loss: (2) (3) RF (GHz) 2.0-26.5 1.5-26.5 1.5-26.5 Third LO Harmonic (2) (3) Conversion Loss: 6.0-26.5 6.0-26.5 6.0-26.5 Isolation LO to RF: LO (GHz) 2.0-26.5 1.5-26.5 1.5-26.5 IF (MHz) DC-500 DC-700 DC-1250 2.0-9.0 2.0-9.0 2.0-9.0 DC-500 DC-700 DC-1250 1.5-3.0 3.0-26.5 1.5-4.0 4.0-18.0 18.0-26.5 Min 18 dB 20 dB 18 dB Typical 7.5 dB 8.5 dB 9.5 dB Max 9.50 dB 10.0 dB 11.5 dB 17.5 dB 18.5 dB 19.5 dB 22 dB 23 dB 24 dB Input 1-dB Compression Point: 1.5-26.5 1.5-26.5 DC-1250 25 dB 30 dB 5 dB 25 dB 35 dB 23 dB 35 dB +3 dBm Input Third Order Intercept Point: 1.5-26.5 1.5-26.5 DC-1250 +12 dBm LO Power: (4) 1.5-26.5 1.5-26.5 DC-1250 +9 dBm LO to IF: RF to IF: 1.5-4.0 4.0-26.5 20 dB Notes: 1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25 C with the nominal LO power. Specifications indicated as typical are not guaranteed. 2. Noise figure is typically within ±0.5 dB of conversion loss for IF frequencies greater than 10 MHz. 3. Conversion loss typically degrades less than 0.5 dB at +100 C and improves less than 0.5 dB at -55 C. 4. Usable LO drives are up to 2 dB below and 3 dB above nominal. MM134xG-1 Model MM134xG-1 Drop-In Module or With SMA(F) Connectors M = Module P = With Connectors Typical Performance at 25°C Outline: G- .015D All dimensions are in inches and [mm]. Rev. Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532 1/11/07 www.SpectrumMicrowave.com Spectrum Microwave (Europe) · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001