Triple Balanced Mixer Model MM9xxN-1 Ultra-Broadband RF 2.0 to 19.0 GHz Electrical Specifications:(1) Specifications Conditions Parameter SSB Conversion loss:(2) (3) Isolation LO to RF: LO to IF: RF to IF: IF to RF: Input 1 dB Compression Point: RF (GHz) 3.0-17.0 3.0-19.0 3.0-19.0 2.0-19.0 2.0-19.0 LO (GHz) 3.0-17.0 3.0-19.0 3.0-19.0 2.0-19.0 IF (GHz) 2.0-6.0 2.0-8.0 1.0-9.0 1.0-9.0 2.0-19.0 2.0-19.0 2.0-19.0 2.0-19.0 1.0-9.0 1.0-9.0 Input Third Order Intercept Point: 2.0-19.0 2.0-19.0 1.0-9.0 LO Power: (4) 2.0-19.0 2.0-19.0 1.0-9.0 Min Typical 7.0 dB 7.5 dB 8.0 dB 8.0 dB 15 dB 17 dB 24 dB 30 dB 22 dB 25 dB +5 dBm +8 dBm +12 dBm +15 dBm +14 dBm +17 dBm +21 dBm +24 dBm +10 dBm +13 dBm +17 dBm +21 dBm Notes: 1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system from -55˚C to +100˚C with the nominal LO power. Specifications indicated as typical are not guaranteed. 2. Noise figure is typically within ±0.5 dB of conversion loss. 3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C. 4. Usable LO drives are up to 2 dB below and 3 dB above nominal. MM9xxN-1 Outline: N Max 9.5 dB 11.0 dB 12.5 dB 13.5 dB Model MM9xxN-1 LO Power 4 = +10 dBm 6 = +13 dBm 7 = +17 dBm 8 = +21 dBm MM94 MM96 MM97 MM98 MM94 MM96 MM97 MM98 MM94 MM96 MM97 MM98 Drop-In Module or With SMA(F) Connectors M = Module P = With Connectors Typical Performance at 25˚C All dimensions are in inches and [mm]. Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532 www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001 REV A 10/29/09