TOTAL POWER INT. D60 AC-DC 60W POWER SUPPLY WITH DUAL OUTPUT .LOW COST, HIGH RELIABILITY .COMPACT SIZE, LIGHT WEIGHT .105 ºC OUTPUT CAPACITOR .100% FULL LOAD BURN-IN TEST .INTERNATIONAL AC INPUT RANGE .BUILT IN EMI FILTER, LOW RIPPLE NOISE .HIGH EFFICIENCY, LOW WORKING TEMPERATURE .SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT .SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED D-60A MODEL SPECIFICATION CH1 CH2 CH1 CH2 5V 12V 5V 24V ±2% ±6% ±2% ±5% DC OUTPUT VOLTAGE OUTPUT V. TOLERANCE D-60B OUTPUT RATED CURRENT 4A 3A 3A 1.8A OUTPUT CURRENT RANGE 0.3-6A 0.2-4A 0.3-6A 0.2-2.2A RIPPLE & NOISE 75mVp-p 150mVp-p 75mVp-p 150mVp-p LINE REGULATION ±0.5% ±1% ±0.5% ±0.5% LOAD REGULATION ±0.5% ±4% ±0.5% ±4% DC OUTPUT POWER 56W 58W EFFICIENCY 73% 76% CH1:+10,-5% CH1:+10,-5% DC VOLTAGE ADJ. INPUT VOLTAGE RANGE 85~264VAC 47~63Hz; 120~370VDC AC CURRENT 2A/115V 1A/230V INRUSH CURRENT COLD START 30A/115V 60A/230V LEAKAGE CURRENT <1mA/240VAC OVERLOAD PROTECTION 105%~150% TYPE:PULSING HICCUP SHUTDOWN RESET:AUTO RECOVERY OVER VOLTAGE PROTECTION CH1:5.75~6.75V OVER TEMP. PROTECTION ---------- TEMP. COEFFICIENT ±0.03% / ºC (0~50 ºC) ON +5V OUTPUT SETUP, RISE, HOLD UP TIME 800ms, 50ms, 10ms / 115VAC 300ms, 50ms, 80ms / 230VAC VIBRATION 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms WORKING TEMP., HUMIDITY -10 ºC~+60 ºC(REFER TO OUTPUT DERATING CURVE), 20%~90% RH STORAGE TEMP., HUMIDITY -20 ºC~+85 ºC, 10%~95% RH DIMENSION 159*97*38mm CASE:901 WEIGHT 0.55Kgs SAFETY STANDARDS UL1012, TUV EN60950, IEC950, UL1950 APPROVED EMC STANDARDS CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 VERIFICATION NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT. 2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION. 3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR. 4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD. 5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD. 6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 7.C2,3,6 MUST BE REMOVED. 2000-10-03