TI SN74LVC2G74-EP

SN74LVC2G74-EP
www.ti.com ....................................................................................................................................................................................................... SCES718 – MAY 2008
SINGLE POSITIVE EDGE TRIGGERED D-TYPE FLIP-FLOP
WITH CLEAR AND PRESET
FEATURES
1
•
•
•
•
•
•
(1)
Controlled Baseline
– One Assembly Site
– One Test Site
– One Fabrication Site
Extended Temperature Performance of –55°C
to 125°C
Enhanced Diminishing Manufacturing Sources
(DMS) Support
Enhanced Product-Change Notification
Qualification Pedigree (1)
Supports 5-V VCC Operation
Component qualification in accordance with JEDEC and
industry standards to ensure reliable operation over an
extended temperature range. This includes, but is not limited
to, Highly Accelerated Stress Test (HAST) or biased 85/85,
temperature cycle, autoclave or unbiased HAST,
electromigration, bond intermetallic life, and mold compound
life. Such qualification testing should not be viewed as
justifying use of this component beyond specified
performance and environmental limits.
•
•
•
•
•
•
•
•
•
Inputs Accept Voltages to 5.5 V
Max tpd of 7.9 ns at 3.3 V
Low Power Consumption, 10 µA Max ICC
±24 mA Output Drive at 3.3 V
Typical VOLP (Output Ground Bounce)
<0.8 V at VCC = 3.3 V, TA = 25°C
Typical VOHV (Output VOH Undershoot)
>2 V at VCC = 3.3 V, TA = 25°C
Ioff Supports Partial Power Down Mode
Operation
Latch-Up Performance Exceeds 100 mA Per
JESD 78, Class II
ESD Protection Exceeds JESD 22
– 2000-V Human-Body Model (A114-A)
– 200-V Machine Model (A115-A)
– 1000-V Charged-Device Model (C101)
DCU PACKAGE
(TOP VIEW)
CLK
D
Q
GND
1
8
VCC
2
7
3
6
4
5
PRE
CLR
Q
DESCRIPTION/ORDERING INFORMATION
This single positive edge triggered D-type flip-flop is designed for 1.65-V to 5.5-V VCC operation.
A low level at the preset (PRE) or clear (CLR) input sets or resets the outputs, regardless of the levels of the
other inputs. When PRE and CLR are inactive (high), data at the data (D) input meeting the setup time
requirements is transferred to the outputs on the positive-going edge of the clock pulse. Clock triggering occurs
at a voltage level and is not related directly to the rise time of the clock pulse. Following the hold-time interval,
data at the D input can be changed without affecting the levels at the outputs.
This device is fully specified for partial power down applications using Ioff. The Ioff circuitry disables the outputs,
preventing damaging current backflow through the device when it is powered down.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2008, Texas Instruments Incorporated
SN74LVC2G74-EP
SCES718 – MAY 2008 ....................................................................................................................................................................................................... www.ti.com
ORDERING INFORMATION (1)
PACKAGE (2)
TA
–55°C to 125°C
(1)
(2)
(3)
ORDERABLE PART NUMBER
VSSOP – DCU
Reel of 250
SN74LVC2G74MDCUTEP
TOP-SIDE MARKING (3)
CHB
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
Package drawings, thermal data, and symbolization are available at www.ti.com/packaging.
DCU: The actual top-side marking has one additional character that designates the assembly/test site.
FUNCTION TABLE
INPUTS
(1)
OUTPUTS
PRE
CLR
CLK
D
Q
Q
L
H
X
X
H
L
H
L
X
X
L
H
L
L
X
X
H (1)
H (1)
H
H
↑
H
H
L
H
H
↑
L
L
H
H
H
L
X
Q0
Q0
This configuration is nonstable; that is, it does not persist when PRE or CLR returns to its inactive
(high) level.
LOGIC DIAGRAM (POSITIVE LOGIC)
PRE
CLK
7
1
C
C
C
5
Q
TG
C
C
C
C
D
2
TG
TG
TG
3
C
CLR
2
C
Q
C
6
Submit Documentation Feedback
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC2G74-EP
SN74LVC2G74-EP
www.ti.com ....................................................................................................................................................................................................... SCES718 – MAY 2008
Absolute Maximum Ratings (1)
over operating free-air temperature range (unless otherwise noted)
MIN
MAX
VCC
Supply voltage range
–0.5
6.5
V
VI
Input voltage range (2)
–0.5
6.5
V
–0.5
6.5
V
–0.5
VCC + 0.5
(2)
UNIT
VO
Voltage range applied to any output in the high-impedance or power-off state
VO
Voltage range applied to any output in the high or low state (2) (3)
IIK
Input clamp current
VI < 0
–50
mA
IOK
Output clamp current
VO < 0
–50
mA
IO
Continuous output current
±50
mA
±100
mA
227
°C/W
150
°C
Continuous current through VCC or GND
θJA
Package thermal impedance
Tstg
Storage temperature range
(1)
(2)
(3)
(4)
(4)
DCU package
–65
V
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input negative-voltage and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
The value of VCC is provided in the recommended operating conditions table.
The package thermal impedance is calculated in accordance with JESD 51-7.
Submit Documentation Feedback
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC2G74-EP
3
SN74LVC2G74-EP
SCES718 – MAY 2008 ....................................................................................................................................................................................................... www.ti.com
Recommended Operating Conditions (1)
VCC
Supply voltage
Operating
Data retention only
High-level input voltage
MAX
1.65
5.5
1.5
VCC = 2.3 V to 2.7 V
1.7
VCC = 3 V to 3.6 V
0.7 × VCC
0.35 × VCC
VCC = 1.65 V to 1.95 V
Low-level input voltage
V
V
2
VCC = 4.5 V to 5.5 V
VIL
UNIT
0.65 × VCC
VCC = 1.65 V to 1.95 V
VIH
MIN
VCC = 2.3 V to 2.7 V
0.7
VCC = 3 V to 3.6 V
0.8
V
0.3 × VCC
VCC = 4.5 V to 5.5 V
VI
Input voltage
0
5.5
V
VO
Output voltage
0
VCC
V
VCC = 1.65 V
–4
VCC = 2.3 V
IOH
High-level output current
–8
–16
VCC = 3 V
VCC = 4.5 V
–24
VCC = 1.65 V
4
VCC = 2.3 V
IOL
Low-level output current
Δt/Δv
Input transition rise or fall rate
8
16
VCC = 3 V
24
VCC = 1.8 V ± 0.15 V, 2.5 V ± 0.2 V
20
VCC = 3.3 V ± 0.3 V
10
(1)
4
Operating free-air temperature
mA
24
VCC = 4.5 V
VCC = 5 V ± 0.5 V
TA
mA
–24
ns/V
5
–55
125
°C
All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Submit Documentation Feedback
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC2G74-EP
SN74LVC2G74-EP
www.ti.com ....................................................................................................................................................................................................... SCES718 – MAY 2008
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
IOH = –100 µA
VOH
1.65 V to 5.5 V
1.65 V
1.2
IOH = –8 mA
2.3 V
1.9
4.5 V
IOL = 100 µA
1.65 V to 5.5 V
0.1
IOL = 4 mA
1.65 V
0.45
IOL = 8 mA
2.3 V
0.3
IOL = 24 mA
Data or
control inputs
0.4
VI = 5.5 V or GND
VI or VO = 5.5 V
ICC
VI = 5.5 V or GND,
IO = 0
ΔICC
One input at VCC – 0.6 V,
Other inputs at VCC or GND
Ci
VI = VCC or GND
V
0.55
4.5 V
Ioff
(1)
3.8
3V
IOL = 24 mA
II
2.3
IOH = –24 mA
IOL = 16 mA
UNIT
V
2.4
3V
IOH = –24 mA
MAX
VCC – 0.1
IOH = –4 mA
IOH = –16 mA
VOL
MIN TYP (1)
VCC
0.55
0 to 5.5 V
±5
µA
0
±10
µA
1.65 V to 5.5 V
10
µA
3 V to 5.5 V
500
µA
3.3 V
5
pF
All typical values are at VCC = 3.3 V, TA = 25°C.
Timing Requirements
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
VCC = 3.3 V
± 0.3 V
MIN
fclock
MAX
VCC = 5 V
± 0.5 V
MIN
175
tw
Pulse duration
tsu
Setup time, before CLK↑
th
Hold time, data after CLK↑
200
CLK
2.7
2
PRE or CLR low
2.7
2
Data
1.3
1.1
PRE or CLR inactive
1.2
1.2
1.2
0.5
UNIT
MAX
MHz
ns
ns
ns
Switching Characteristics
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
fmax
tpd
VCC = 3.3 V
± 0.3 V
MIN
MAX
175
CLK
PRE or CLR
VCC = 5 V
± 0.5 V
MIN
200
MHz
Q
2.2
7.9
1.4
6.1
Q
2.6
8.2
1.6
6.4
Q or Q
1.7
7.9
1.6
6.1
Submit Documentation Feedback
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC2G74-EP
UNIT
MAX
ns
5
SN74LVC2G74-EP
SCES718 – MAY 2008 ....................................................................................................................................................................................................... www.ti.com
Operating Characteristics
TA = 25°C
PARAMETER
Cpd
6
Power dissipation capacitance
TEST CONDITIONS
f = 10 MHz
Submit Documentation Feedback
VCC = 3.3 V
VCC = 5 V
TYP
TYP
37
40
UNIT
pF
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC2G74-EP
SN74LVC2G74-EP
www.ti.com ....................................................................................................................................................................................................... SCES718 – MAY 2008
PARAMETER MEASUREMENT INFORMATION
VLOAD
S1
RL
From Output
Under Test
Open
TEST
GND
CL
(see Note A)
S1
Open
VLOAD
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
RL
GND
LOAD CIRCUIT
INPUTS
VCC
1.8 V ± 0.15 V
2.5 V ± 0.2 V
3.3 V ± 0.3 V
5 V ± 0.5 V
VI
tr/tf
VCC
VCC
3V
VCC
£2 ns
£2 ns
£2.5 ns
£2.5 ns
VM
VLOAD
CL
RL
VD
VCC/2
VCC/2
1.5 V
VCC/2
2 × VCC
2 × VCC
6V
2 × VCC
30 pF
30 pF
50 pF
50 pF
1 kW
500 W
500 W
500 W
0.15 V
0.15 V
0.3 V
0.3 V
VI
Timing Input
VM
0V
tW
tsu
VI
Input
VM
VM
th
VI
Data Input
VM
VM
0V
0V
VOLTAGE WAVEFORMS
PULSE DURATION
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VI
VM
Input
VM
0V
tPLH
VOH
VM
VOL
tPHL
0V
VLOAD/2
VM
tPZH
VM
VM
VM
tPLZ
Output
Waveform 1
S1 at VLOAD
(see Note B)
tPLH
VOH
Output
VM
tPZL
tPHL
VM
Output
VI
Output
Control
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
INVERTING AND NONINVERTING OUTPUTS
Output
Waveform 2
S1 at GND
(see Note B)
VOL + VD
VOL
tPHZ
VM
VOH – VD
VOH
»0 V
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
LOW- AND HIGH-LEVEL ENABLING
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low, except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high, except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR £ 10 MHz, ZO = 50 W.
D. The outputs are measured one at a time, with one transition per measurement.
E. tPLZ and tPHZ are the same as tdis.
F. tPZL and tPZH are the same as ten.
G. tPLH and tPHL are the same as tpd.
H. All parameters and waveforms are not applicable to all devices.
Figure 1. Load Circuit and Voltage Waveforms
Submit Documentation Feedback
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s): SN74LVC2G74-EP
7
PACKAGE MATERIALS INFORMATION
www.ti.com
20-Jan-2011
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
SN74LVC2G74MDCUTEP
Package Package Pins
Type Drawing
US8
DCU
8
SPQ
250
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
180.0
8.4
Pack Materials-Page 1
2.25
B0
(mm)
K0
(mm)
P1
(mm)
3.35
1.05
4.0
W
Pin1
(mm) Quadrant
8.0
Q3
PACKAGE MATERIALS INFORMATION
www.ti.com
20-Jan-2011
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
SN74LVC2G74MDCUTEP
US8
DCU
8
250
202.0
201.0
28.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Audio
www.ti.com/audio
Communications and Telecom www.ti.com/communications
Amplifiers
amplifier.ti.com
Computers and Peripherals
www.ti.com/computers
Data Converters
dataconverter.ti.com
Consumer Electronics
www.ti.com/consumer-apps
DLP® Products
www.dlp.com
Energy and Lighting
www.ti.com/energy
DSP
dsp.ti.com
Industrial
www.ti.com/industrial
Clocks and Timers
www.ti.com/clocks
Medical
www.ti.com/medical
Interface
interface.ti.com
Security
www.ti.com/security
Logic
logic.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Power Mgmt
power.ti.com
Transportation and
Automotive
www.ti.com/automotive
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
Wireless
www.ti.com/wireless-apps
RF/IF and ZigBee® Solutions
www.ti.com/lprf
TI E2E Community Home Page
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated