SN74AHC1G86-EP SINGLE 2-INPUT EXCLUSIVE-OR GATE www.ti.com SCLS709 – FEBRUARY 2008 • • • • FEATURES 1 • • • • • • (1) Controlled Baseline – One Assembly Site – One Test Site – One Fabrication Site Extended Temperature Performance of –55°C to 125°C Enhanced Diminishing Manufacturing Sources (DMS) Support Enhanced Product-Change Notification Qualification Pedigree (1) Operating Range of 2 V to 5.5 V • • • Component qualification in accordance with JEDEC and industry standards to ensure reliable operation over an extended temperature range. This includes, but is not limited to, Highly Accelerated Stress Test (HAST) or biased 85/85, temperature cycle, autoclave or unbiased HAST, electromigration, bond intermetallic life, and mold compound life. Such qualification testing should not be viewed as justifying use of this component beyond specified performance and environmental limits. 1 B 2 GND 3 ESD Protection Exceeds JESD 22 – 2000-V Human-Body Model (A114-A) – 200-V Machine Model (A115-A) – 1000-V Charged-Device Model (C101) DCK PACKAGE (TOP VIEW) DBV PACKAGE (TOP VIEW) A Max tpd of 10 ns at 5 V Low Power Consumption, 10 µA Max ICC ±8 mA Output Drive at 5 V Schmitt Trigger Action at All Inputs Makes the Circuit Tolerant for Slower Input Rise and Fall Time Latch-Up Performance Exceeds 250 mA Per JESD 17 A 1 B 2 GND 3 5 VCC 5 4 DRL PACKAGE (TOP VIEW) VCC Y A 1 B 2 GND 3 5 VCC 4 Y Y 4 See mechanical drawings for dimensions. DESCRIPTION/ORDERING INFORMATION The SN74AHC1G86 is a single 2-input exclusive-OR gate. The device performs the Boolean function Y = A ⊕ B or Y = AB + AB in positive logic. A common application is as a true/complement element. If one of the inputs is low, the other input is reproduced in true form at the output. If one of the inputs is high, the signal on the other input is reproduced inverted at the output. ORDERING INFORMATION (1) TA –55°C to 125°C (1) (2) (3) PACKAGE (2) SOT (SC-70) - DCK Reel of 3000 ORDERABLE PART NUMBER SN74AHC1G86MDCKREP TOP-SIDE MARKING (3) CGB For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI website at www.ti.com. Package drawings, thermal data, and symbolization are available at www.ti.com/packaging. The actual top-side marking has one additional character that designates the assembly/test site. 1 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2008, Texas Instruments Incorporated SN74AHC1G86-EP SINGLE 2-INPUT EXCLUSIVE-OR GATE www.ti.com SCLS709 – FEBRUARY 2008 FUNCTION TABLE INPUTS A B OUTPUT Y L L L L H H H L H H H L EXCLUSIVE-OR LOGIC An exclusive-OR gate has many applications, some of which can be represented better by alternative logic symbols. EXCLUSIVE OR =1 These are five equivalent exclusive-OR symbols valid for an SN74AHC1G86 gate in positive logic; negation may be shown at any two ports. LOGIC-IDENTITY ELEMENT EVEN-PARITY ELEMENT = 2k The output is active (low) if all inputs stand at the same logic level (i.e., A = B). The output is active (low) if an even number of inputs (i.e., 0 or 2) are active. ODD-PARITY ELEMENT 2k + 1 The output is active (high) if an odd number of inputs (i.e., only 1 of the 2) are active. Absolute Maximum Ratings (1) over operating free-air temperature range (unless otherwise noted) VCC MIN MAX Supply voltage range –0.5 7 UNIT V (2) –0.5 7 V –0.5 VCC + 0.5 VI Input voltage range VO Output voltage range (2) IIK Input clamp current VI < 0 –20 mA IOK Output clamp current VO < 0 or VO = 0 to VCC ±20 mA IO Continuous output current VO = 0 to VCC ±25 mA Continuous current through VCCor GND VCC or GND ±50 mA 252 °C/W 150 °C θJA Package thermal impedance Tstg Storage temperature range (1) (2) (3) 2 (3) DCK package –65 V Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed. The package thermal impedance is calculated in accordance with JESD 51-7. Submit Documentation Feedback Copyright © 2008, Texas Instruments Incorporated Product Folder Link(s): SN74AHC1G86-EP SN74AHC1G86-EP SINGLE 2-INPUT EXCLUSIVE-OR GATE www.ti.com SCLS709 – FEBRUARY 2008 Recommended Operating Conditions (1) MIN VCC Supply voltage VIH High-level input voltage MAX 2 VCC = 2 V 1.5 VCC = 3 V 2.1 VCC = 5.5 V UNIT 5.5 V V 3.85 VCC = 2 V 0.5 VCC = 3 V 0.9 VIL Low-level input voltage VI Input voltage 0 5.5 VO Output voltage 0 VCC V –50 µA VCC = 5.5 V 1.65 VCC = 2 V IOH High-Level output current IOL Low-Level output current Δt/Δv Input transition rise or fall rate TA Operating free-air temperature (1) V VCC = 3.3 V ± 0.3 V –4 VCC = 5 V ± 0.5 V –8 VCC = 2 V 50 VCC = 3.3 V ± 0.3 V 4 VCC = 5 V ± 0.5 V 8 VCC = 3.3 V ± 0.3 V 100 VCC = 5 V ± 0.5 V 20 –55 V mA µA mA ns/V 125 °C All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004. Submit Documentation Feedback Copyright © 2008, Texas Instruments Incorporated Product Folder Link(s): SN74AHC1G86-EP 3 SN74AHC1G86-EP SINGLE 2-INPUT EXCLUSIVE-OR GATE www.ti.com SCLS709 – FEBRUARY 2008 Electrical Characteristics over operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VCC IOH = –50 µA TA = –55°C TO 125°C TYP 2V 1.9 2 1.9 2.9 3V 2.9 3 4.5 V 4.4 4.5 IOH = –4 mA 3V 2.58 IOH = –8 mA 4.5 V 3.94 VOH IOL = 50 µA VOL IOL = 4 mA IOL = 8 mA II TA = 25°C MIN VI = 5.5 V or GND ICC VI = VCC or GND, O = 0 Ci VI = VCC or GND MAX MIN MAX 4.4 UNIT V 2.48 3.8 2V 0.1 0.1 3V 0.1 0.1 4.5 V 0.1 0.1 3V 0.36 0.44 4.5 V 0.36 0.44 0 V to 5.5 V ±0.1 ±1 µA 1 10 µA 10 10 pF 5.5 V 5V 4 V Switching Characteristics over operating free-air temperature range, VCC = 3.3 ± 0.3 V (unless otherwise noted) (see Figure 1) PARAMETER tPLH FROM (INPUT) TO (OUTPUT) LOAD CAPACITANCE A or B Y CL = 50 pF TA = 25°C MIN tPHL TA = –55°C TO 125°C UNIT TYP MAX MIN MAX 9.5 14.5 1 16.5 ns 9.5 14.5 1 16.5 ns Switching Characteristics over operating free-air temperature range, VCC = 5 ± 0.5 V (unless otherwise noted) (see Figure 1) PARAMETER tPLH tPHL FROM (INPUT) TO (OUTPUT) LOAD CAPACITANCE A or B Y CL = 50 pF TA = 25°C MIN TA = –55°C TO 125°C TYP MAX MIN MAX 6.3 8.8 1 10 6.3 8.8 1 10 UNIT ns Operating Characteristics VCC = 5 V, TA = 25°C PARAMETER Cpd 4 Power dissipation capacitance TEST CONDITIONS No load, f = 1 MHz Submit Documentation Feedback TYP 18 UNIT pF Copyright © 2008, Texas Instruments Incorporated Product Folder Link(s): SN74AHC1G86-EP SN74AHC1G86-EP SINGLE 2-INPUT EXCLUSIVE-OR GATE www.ti.com SCLS709 – FEBRUARY 2008 PARAMETER MEASUREMENT INFORMATION VCC From Output Under Test Test Point RL = 1 kΩ From Output Under Test CL (see Note A) S1 Open TEST GND CL (see Note A) LOAD CIRCUIT FOR TOTEM-POLE OUTPUTS S1 tPLH/tPHL tPLZ/tPZL tPHZ/tPZH Open Drain Open VCC GND VCC LOAD CIRCUIT FOR 3-STATE AND OPEN-DRAIN OUTPUTS VCC 50% VCC Timing Input tw tsu VCC 50% VCC Input 50% VCC 0V th VCC 50% VCC Data Input 50% VCC 0V 0V VOLTAGE WAVEFORMS PULSE DURATION VOLTAGE WAVEFORMS SETUP AND HOLD TIMES VCC 50% VCC Input 50% VCC 0V tPLH In-Phase Output tPHL 50% VCC tPHL Out-of-Phase Output VOH 50% VCC VOL Output Waveform 1 S1 at VCC (see Note B) VOH 50% VCC VOL VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES INVERTING AND NONINVERTING OUTPUTS 50% VCC 50% VCC 0V tPZL tPLZ ≈VCC 50% VCC tPZH tPLH 50% VCC VCC Output Control VOL + 0.3 V VOL tPHZ Output Waveform 2 S1 at GND (see Note B) 50% VCC VOH − 0.3 V VOH ≈0 V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES LOW- AND HIGH-LEVEL ENABLING NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low, except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high, except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr ≤ 3 ns, tf ≤ 3 ns. D. The outputs are measured one at a time, with one input transition per measurement. E. All parameters and waveforms are not applicable to all devices. Figure 1. Load Circuit and Voltage Waveforms Submit Documentation Feedback Copyright © 2008, Texas Instruments Incorporated Product Folder Link(s): SN74AHC1G86-EP 5 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps DSP dsp.ti.com Energy and Lighting www.ti.com/energy Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial Interface interface.ti.com Medical www.ti.com/medical Logic logic.ti.com Security www.ti.com/security Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2012, Texas Instruments Incorporated