RUC Plug-in power relays • General purpose relays • High inrush current • Plug-in, solder, PCB, connector mounting • Covers with mounting flange available Contacts Contacts Contact number & arrangement Contact material Voltage Max. switching voltage AC/DC Min. switching voltage Current Rated load AC1 DC1 Min. switching current Max. inrush current Rated current Max. breaking capacity Min. breaking capacity Resistance Max. operating frequency • at rated load • no load 2C/O, 3C/O, 2NO, 3NO AgCdO 400 V / 400 V 10 V 16 A / 250 V AC or 10 A / 380 V AC 16 A / 24 V DC 10 mA 40 A 16 A 4 000 VA 0,5 W £ 100 mW at 1 A, 24 V 1 200 cycles/hour 12 000 cycles/hour Coil Coil Voltage Rated voltage on 6...220 V DC 6...380 V AC 50 Hz, 50/60 Hz ³ 0,1 Un DC; ³ 0,15 Un AC see Tables 1, 2, 3 1,5 W DC 2,8 VA AC 50 Hz; 2,5 VA AC 60 Hz Must release voltage Operating range of supply voltage Rated power consumption Insulation Insulation Insulation category Voltage Insulation rated voltage Dielectric strength: • coil-contact • contact-contact • pole-pole Contact-coil distance • clearance • creepage C400 400 V AC 2 500 V AC 1 500 V AC (2 500 V AC contact-contact ³ 3 mm) 2 500 V AC ³ 6 mm ³ 8 mm General data General data Operating time (typical value) Release time (typical value) Electrical life • resistive • cos j Mechanical life (cycles) Dimensions (L x W x H) Weight Ambient temperature • storing • operating 12 ms AC, 12 ms DC 10 ms AC, 7 ms DC Cover protection category Shock resistance Vibration resistance Solder bath temperature Soldering time Approvals at 16 A, 250 V AC ³ 105 see Fig. 2 ³ 107 38,6 x 36,1 x 45,5 mm 85 g -40...+85 °C -40...+70 °C (for 10 A on contact) -40...+55 °C (for 16 A on contact) IP 40 10 g 5g for 10...150 Hz max. 270 °C max. 5 s B, UL, CSA, GOST 1 2 RUC Plug-in power relays RUC Plug-in power relays 3 4 RUC Max. DC resistive load breaking capacity Plug-in power relays Fig. 3 Mounting Relays RUC are designed for: • screw terminals sockets GUC11 (modules and clips available) - for DIN rail mounting, • fast-on connector, • direct PCB mounting. Ordering codes See Tables 1, 2, 3, page 2 2002-12-20