ARTESYN CMP350-9623

CMP350 SERIES
Quad output
•
•
•
•
•
•
•
•
[ 2 YEAR WARRANTY ]
SPECIFICATION
10 x 5 inch footprint with 1.75 inch low profile
EN61000-3-2 compliant
Current sharing
Individually protected outputs
Power fail signals
350W with 300LFM
EN55022, EN55011 conducted emissions level B
UL, VDE and CSA safety approvals
The CMP350 series is a 350W universal input AC/DC power supply in a 10 x 5 x
1.75 inch package. The series has the lowest standard 350W profile in the
industry, input harmonic current emission correction as standard, current sharing
and has 3.3V models to support the industry's transition from 5V to lower
operating voltages. The CMP350 provides 350W of output power with 300LFM of
forced air. Standard features include isolated outputs with individual overvoltage
and overload protection on each output. The series has an enclosure with endmounted fans option that does not change the overall height. The series, with full
international safety approval and the CE mark, meets conducted emissions
EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The
CMP350 series is designed for use in medium power data networking, computer
and telecom applications such as hubs, routers, file servers, graphic workstations
and mass storage peripherals. It is also suitable for industrial, test and office
applications.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
EMC CHARACTERISTICS
OUTPUT SPECIFICATIONS
Output accuracy
Total regulation
(Line and load)
Transient response
±1.0%
Main and auxiliary V1 output
Auxiliary output (V2)
Auxiliary output (V3)
Main output
25% step load
change at 1A/µs
Temperature coefficient
±1.0%
±6.0%
±5.0%
2.0% max. dev.,
500µs recovery
±0.02%/°C
Ripple and noise
(See Note 3)
0Hz to 20MHz
50mV pk-pk
or 1.0%
Overvoltage protection
Latching
Short circuit protection
All channels
Continuous,
auto recovery
Overload protection
All channels
Yes
See table
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-2
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level
Level
Level
Level
Level
Level
Current sharing
Auto shutdown,
auto recovery
Main output and
Aux. 1 (5V and 3V3)
±10% of rating
INPUT SPECIFICATIONS
Input voltage range
Universal
90 to 264VAC
(30s brown-out at 85VAC)
Input frequency range
47Hz to 63Hz
Input surge voltage
300VAC
Inrush current
264VAC, cold start
Safety ground
leakage current
Input current
Hold-up time
110VAC, 60Hz, 350W
Efficiency
Isolation voltage
Approvals and
standards
110VAC, 350W
Input/output
Input/chassis
Output/output
3000VAC
1500VAC
50VDC
UL, IEC approved
Power factor
110/220VAC full load
6.3A 250V
0.97 min.
150kHz
EN60950, VDE0805, UL1950,
CSA C22.2 No. 950
2.0kg (4.4Ibs)
Size
(See Note C)
Open frame
Enclosed
MTBF
MIL-HDBK-217F
Bellcore TR-NWT-332
10.0 x 5 x 1.75 inches
10.5 x 5 x 1.75 inches
212,707 hours
959,870 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient, FL
0°C to +50°C
Cooling
300LFM airflow required
+50°C to +70°C, Derate to 50% load
ambient
on all channels
Non-operating
-40°C to +85°C
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
75A max.
4.2Arms max.
16ms
75% typical
Weight
0.72mA
Input fuse
PAGE 62
20ms
3
3
3
3
3
3
GENERAL SPECIFICATIONS
Switching frequency
Thermal protection
Level B
Level A
Compliant
Vibration (See Note 15) 5Hz to 500Hz
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4G rms peak
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
350W AC/DC
350 Watt
AC/DC high wattage power supplies with PFC
OUTPUT CURRENT
OUTPUT
OUTPUT
VOLTAGE
TYPE
5V
Main
0A
TOTAL
OVP
ADJUST
MODEL
REGULATION
THRESHOLD
RANGE
NUMBERS
50mV
±1.0%
5.75 to 6.75V
+10, -5%
CMP350-9604
RIPPLE
MIN
(1)
MAX
(3)
(2)
50A
3.3V
(2)
Aux 1
1.0A
20A
(8)
50mV
±1.0%
4.15 to 4.35V
+20, -5%
12V
(2)
Aux 2
1.0A
10A
(8)
120mV
±1.0%
13.2 to 14.5V
±5%
12V
(2)
Aux 3
0.5A
5.0A
(8)
120mV
±5.0%
Main
0A
50A
50mV
±1.0%
5.75 to 6.75V
+10, -5%
13.2 to 14.5V
±5%
5V
12.6 to 15.2V
(4)
(2)
Aux 1
1.0A
10A
120mV
±1.0%
12V
(2)
Aux 2
0.5A
5.0A
120mV
±5.0%
Aux 3
0.5A
5.0A
50mV
±1.0%
5.75 to 6.75V
(7)
Main
0A
50A
50mV
±1.0%
5.75 to 6.75V
+10, -5%
13.2 to 14.5V
±5%
5V
(2)
5V
(4)
(2)
Aux 1
1.0A
10A
120mV
±1.0%
12V
(2)
Aux 2
0.5A
5.0A
120mV
±5.0%
24V
(2)
Aux 3
0.2A
2.0A
240mV
±1.0%
26.4 to 28.8V
(7)
Main
0A
50A
50mV
±1.0%
5.75 to 6.75V
+10, -5%
16.5 to 18.0V
±5%
5V
(4)
(2)
Aux 1
0.8A
8.0A
150mV
±1.0%
15V
(2)
Aux 2
0.4A
4.0A
150mV
±5.0%
24V
(2)
Aux 3
0.2A
2.0A
240mV
±1.0%
26.4 to 28.8V
(7)
Main
0A
50A
50mV
±1.0%
5.75 to 6.75V
+10, -5%
13.2 to 14.5V
±5%
5V
(4)
(2)
Aux 1
1.0A
10A
120mV
±1.0%
12V
(2)
Aux 2
0.5A
5.0A
120mV
±5.0%
12V
(2)
Aux 3
0.3A
3.0A
120mV
±1.0%
13.2 to 14.5V
(7)
Main
0A
50A
50mV
±1.0%
4.15 to 4.35V
+20, -5%
Aux 1
1.0A
15A
(9)
50mV
±1.0%
5.75 to 6.75V
+10, -5%
13.2 to 14.5V
±5%
3.3V
5V
(2)
(4)
(2)
Aux 2
0.5A
5.0A
(9)
120mV
±1.0%
12V
(2)
Aux 3
0.5A
5.0A
(9)
120mV
±5.0%
24V
Main
0A
10A
240mV
±1.0%
26.4 to 28.8V
±5%
5V
Aux 1
1.0A
15A
50mV
±1.0%
5.75 to 6.75V
+10, -5%
12V
Aux 2
1.0A
10A
120mV
±1.0%
13.2 to 14.5V
±5%
12V
Aux 3
5.0A
5.0A
120mV
±5.0%
12.6 to 15.2V
CMP350-9606
CMP350-9603
(5)
12V
12.6 to 15.2V
CMP350-9602
(5)
12V
12.6 to 15.2V
CMP350-9601
(5)
15V
15.7 to 19.0V
1
(5)
12V
12.6 to 15.2V
(8)
(6)
12V
12.6 to 15.2V
(A)
(4)
CMP350-9692
(9)
(6)
(4)
CMP350-9623
(6)
DERATING CURVE (See Notes 10, 11)
Output Power (Watts)
350W
International Safety Standard Approvals
300LFM
FORCED AIR
COOLING
VDE0805/EN60950/IEC950 Licence No. 96709
175W
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
20W
0W
20W MINIMUM LOAD REQUIRED TO MAINTAIN
REGULATION
0°C 10°C
http://www.artesyn.com
20°C
30°C
40°C
50°C
60°C
70°C
PAGE 63
350W AC/DC
|
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
350 Watt
AC/DC high wattage power supplies with PFC
TB1
1
VMAIN +
3
VMAIN J1
1
TOP VIEW
TB2
8
Notes:
There are three external accessible connectors in the unit besides the main
Busbar. The first one is designated as TB1 which is the input power
connector.
Pin assignment (TB1)
Main output connector
Input connector TB1 is a standard
screw type terminal block. An IEC
type connector is provided on
enclosed models (suffix ‘CF’).
Main output Busbar connector
VMAIN+ and VMAIN-.
PIN CONNECTIONS
Input connector TB1
PIN NO.
FUNCTION
TB1-1
Live
TB1-2
Ground
TB1-3
Neutral
PIN CONNECTIONS
Output Busbar connector
PIN NO.
FUNCTION
VMAIN+
Positive
VMAINNegative
Auxiliary output pin assignment (TB2)
TB2 auxiliary output connector is used on models -9601, -9602, -9603, -9606.
PIN CONNECTIONS (TB2)
REFERENCE
FUNCTION
AUX CH. 1
Positive
AUX CH. 1
Positive
AUX CH. 1
Negative
AUX CH. 1
Negative
AUX CH. 2
Positive
AUX CH. 2
Negative
AUX CH. 3
Positive
AUX CH. 3
Negative
PIN NO.
TB2-1
TB2-2
TB2-3
TB2-4
TB2-5
TB2-6
TB2-7
TB2-8
Auxiliary output pin assignment (TB2 and TB3)
TB2 and TB3 auxiliary output connectors are used on models -9604 and
-9692. See page 66 for detail.
PIN NO.
TB2-1
TB2-2
TB2-3
TB2-4
TB2-5
TB2-6
TB3-1
TB3-2
PIN CONNECTIONS (TB2 AND TB3)
REFERENCE
FUNCTION
AUX CH. 2
Positive
AUX CH. 2
Positive
AUX CH. 2
Negative
AUX CH. 2
Negative
AUX CH. 3
Positive
AUX CH. 3
Negative
AUX CH. 1
Positive
AUX CH. 1
Negative
PAGE 64
USER INTERFACE PIN (J1)
PIN NO. REFERENCE
J1-3
12CH1
J1-4
12CH2
J1-5
J1-6 *
J1-7
J1-8
J1-9
J1-10
J1-12
J1A-1 *
J1A-2 *
J1A-3 *
J1A-6 *
J1A-7 *
J1A-8
J1A-9
J1A-10
J1A-11
J1A-12
(B)
FUNCTION
12V Bias Refd. to Main Ch. -ve
12V Bias Refd. to Aux. Ch. #1 -ve,
(-9601, -9602, -9603, -9606)
12V Bias Refd. to Aux. Ch. #2 -ve,
(-9604, -9692)
VSENMAIN+
Main Ch. Positive Remote Sense
AUX1SET
(See Note 14)
GND2
Ground Refd. to Aux. Ch. #1 -ve,
(-9601, -9602, -9603, -9606)
Ground Refd. to Aux. Ch. #2 -ve,
(-9604, -9692)
POK (13)
Power Good Detect Signal
GND1
Ground Refd. to Main Ch. -ve
PFD (13)
Power Fail Detect Signal
VSENMAINMain Ch. Negative Remote Sense
VAUXSEN- Auxiliary Channel Negative Remote Sense
VAUXSEN+ Auxiliary Channel Positive Remote Sense
GND3
Ground Refd. to Aux. Ch. 1 +ve for
-9604 and -9692 models
CSAUX (12)
Auxiliary Channel Current Share Pin
TRIMAUX2
Tim Pin for 5V or 3.3V Auxiliary Channel
CSMAIN (12)
Main Channel Current Share Pin
INHIBITInhibit Signal Return
INHIBIT+
Inhibit Signal
TRIMAUX
Trim Pin for 12V or 15V Auxiliary Channel
TRIMAIN
Main Channel Trim Pin
* Applies to -9604, -9692 models only.
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
350W AC/DC
350 Watt
AC/DC high wattage power supplies with PFC
Notes
FEATURES
1
Current share
(See Note 12)
Forced
Main output and
auxiliary 1 if 5V or 3.3V
Power OK
(See Note 13)
Asserted Low
Remote-sense
0.4V
Main output >75%
Main output and
auxiliary 1 if 5V or 3.3V
System inhibit
Asserted high
Power fail detect
(See Note 13)
Asserted low
2
3
Inhibits all outputs
4
5
6
7
8
The unit must be powered up into the recommended minimum loads to
ensure the outputs come up.
Combined maximum output power for Aux. 1, 2 and 3 is 220W.
For models -9604 and -9692, on the aux 1 channel, output ripple and
noise is measured 6 inches down the output cables through a 1 foot long
twisted pair terminated with a parallel combination of a 10µF electrolytic
and a 0.1µF ceramic capacitors. For all other channels on all models,
ripple and noise is measured directly at the output terminals.
No shutdown or latch-up occurs; voltage is internally limited to specified
range.
Aux. 2 tracks Aux. 3, Aux. 4 not adjustable.
Aux. 3 tracks Aux. 2.
Output is not adjustable.
CMP350-9604 rated operation:
Indicates loss of AC
4ms warning
Graph 1
8A
15A
10A
10A
Sum of 12V
Channel
Loads*
AC INPUT
5A
RATED
OPERATION
OUTPUT
0A
5A
10A
15A
20A
3.3 V Channel Load
PFD SIGNAL
POWER GOOD SIGNAL
t1
* Max. load for AUX2 is 10A
Max load for AUX3 is 5A
t2
t1 Varies with line and load
t2 ≥ 4ms
t1 + t2 ≥ 20ms
9
EXTERNAL OUTPUT TRIMMING
The auxiliary channels must share power as indicated by graph 1.
The maximum output power is 220W.
CMP350-9692 rated operation:
(14)
Graph 2
8A
15A
Main channel trim connections
10A
12CH1
Sum of 12V
Channel
Loads*
TRIM
UP/DOWN
TRIMAIN
TRIM
DOWN
TRIM
UP
10A
RATED
OPERATION
5A
0A
5A
10A
15A
5V Channel Load
* Max. load for AUX2 is 10A
Max load for AUX3 is 5A
GND1
Aux. 1 channel trim connections. (-9601, -9602, -9603, 9606)
Aux. 2 channel trim connections (-9604, -9692)
12CH2
10
11
12
TRIM
UP/DOWN
TRIMAUX
TRIM
DOWN
TRIM
UP
13
The auxiliary channels must share power as indicated by graph 2.
The maximum output power is 220W.
A minimum of 300LFM of forced air cooling is required for proper
operation of the CMP350.
All outputs must be derated linearly from maximum specified loads during
operation above 50°C.
Current share is a single wire share circuit that allows the main output on
multiple CMP350 units to be operated in parallel. Auxiliary channels share
on -9604 and -9692 models by connecting the CSAUX channel.
The power fail detect and power OK signals are open-collector outputs
which will sink 40mA or less in the low state and should be pulled up to a
bias voltage with an appropriately sized resistor.
GND2
Aux. 1 channel trim connections (-9604, -9692)
AUX1SET
GND3
TRIM
UP/DOWN
TRIMAUX2
TRIMAUX2 is connected to
AUX1SET by a factory fitted
jumper to ensure CH. 1
regulates at the nominal
set voltage
TRIMAUX2
To trim CH1, remove the
jumper and connect a resistor
between GND3
and TRIMAUX2
http://www.artesyn.com
VOL
IOL
VOH
Min.
0V
0A
4V
Max.
0.4V
-40mA
40V
The system inhibit and output inhibit signals require a current source to be
asserted high.
Min.
Max.
VIH
3.5V
15.0V
IIH
0mA
-10mA
14 Connection from TRIMAUX2 to AUX1SET causes the output for Ch. aux. 1
on models -9604 and -9692 to regulate at its nominal factory set voltage.
15 3 orthogonal axes, random vibration, 10 minute test per axes.
16 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
PAGE 65
1
350W AC/DC
|
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
350 Watt
AC/DC high wattage power supplies with PFC
Mechanical notes
A A standard cover and fan assembly can be added during manufacturing.
To order, add suffix 'CF' to the model number. e.g. CMP350-9601CF.
B Visual arrangement for J1 as seen from the front (output) side of the unit.
C The dimensions of the CMP350-9604 and CMP350-9692 are slightly larger
than shown below. The open frame dimensions are 10.2 x 5 x 1.75 inches
and the enclosed dimensions are 10.7 x 5 x 1.75 inches.
2.250
(57.15)
6.500
(165.1)
Third Angle
Projection
0.870
(22.098)
0.164-32-UNC-2B (6 Places)
(2 On Side, 4 On Bottom)
3/16" (4.76) Max. Thread Penetration - Typ.
0.410
(10.414)
9.90
(251.46)
AC Input
Terminal
Block
1.75
(44.45)
1/4 - 20 UNC Thread
Output Studs
HI
GND
LO
TB1
J1
3.900
(99.06)
TB2
5.00 +0.00/-0.02
(127.00)
1
8
8
0.125 REF.
(3.175)
0.400
(10.160)
6.500
(165.100)
2.250
(57.150)
10.000
(254.000)
See Mechanical Note C
ALL DIMENSIONS IN INCHES (mm)
Tolerances unless otherwise specified
.xx = ± 0.02
.xxx = ± 0.010
Detail:
Mating connectors
(J1) mating connector type
Molex P/N 22-55-2241 or equivalent with Molex
P/N 70058 or equivalent crimp terminals.
J1-1
J1A-12
VMAIN +
Input connector
VMAIN -
IEC for all enclosed models (suffix ‘-CF’).
3-way 0.375 inch pitch terminal block for
uncovered models.
J1
1
Output connectors
2
(TB2) connector type
For models -9601, -9602, -9603 and -9606
8-way 0.197 inch pitch terminal.
TB2
6
J1-12
(TB2) connector type
For models -9604 and -9692
6-way 0.197 inch pitch terminal block.
J1A-1
User Interface Connector J1 View
Vertical mount 2 row, 24 position
TB2 is a 6 way connector on models 9604 and -9692 as shown above.
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
PAGE 66
DS_CMP350_20000101.PDF
(TB3) connector type
For models -9604 and -9692.
2-way 0.375 inch pitch terminal block.
TB3
1