STN3906S Semiconductor PNP Silicon Transistor Descriptions • General purpose small signal amplifier • Switching application Features • Collector saturation voltage : VCE(sat)=-0.5V(Max.) @ IC=-50mA, IB=-5mA • Low output capacitance : Cob=4.5pF(Max.) @ VCB=-5V, IE=0, f=1MHz • Complementary pair with STN3904S Ordering Information Type NO. STN3906S Marking Package Code JA SOT-23 Outline Dimensions unit : mm 1 3 2 PIN Connections 1. Base 2. Emitter 3. Collector KST-2044-002 1 STN3906S Absolute maximum ratings (Ta=25°C) Characteristic Symbol Rating Unit Collector-Base voltage VCBO -40 V Collector-Emitter voltage VCEO -40 V Emitter-Base voltage VEBO -5 V Collector current IC -100 mA Collector power dissipation PC* 350 mW Junction temperature TJ 150 °C Tstg -55~150 °C Storage temperature range * : Package mounted on 99.5% alumina 10×8×0.6mm Electrical Characteristics Characteristic (Ta=25°C) Symbol Test Condition Min. Typ. Max. Unit Collector-Base breakdown voltage BVCBO IC=-10µA, IE=0 -40 - - V Collector-Emitter breakdown voltage BVCEO IC=-1mA, IB=0 -40 - - V Emitter-Base breakdown voltage BVEBO IE=-10µA, IC=0 -5 - - V Collector cut-off current ICBO VCB=-40V, IE= 0 - - -0.1 µA DC current gain hFE VCE=-1V, IC=-10mA 100 - 300 - VCE(sat) IC=-50mA, IB=-5mA - - -0.5 V fT VCE=-20V, IC=-10mA 250 - - MHz - - 4.5 pF Collector-Emitter saturation voltage Transition frequency Collector output capacitance Cob VCB=-5V, IE=0, f=1MHz KST-2044-002 2 STN3906S Electrical Characteristic Curves Fig. 1 PC - Ta Fig. 2 Fig. 3 hFE - IC IC - VBE Fig. 4 IC - VCE ㎂ Fig. 5 VCE(sat) - IC KST-2044-002 3 STN3906S These AUK Corp. products are intended for usage in general electronic equipment (Office and communication equipment, measuring equipment, domestic electrification, etc.) Please make sure that you consult with us before you use these AUK products in equipm ents which require high quality and/or reliability, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic signal, combustion central, all types of safety device, etc.) AUK cannot accept liability to any damage which may occur in case these AUK products were used in the mentioned equipments without prior consultation with AUK. KST-2044-002 4