AUK DN200F

DN200F
Semiconductor
NPN Silicon Transistor
Features
• Extremely low collector-to-emitter saturation voltage
( VCE(SAT)= 0.2V Typ. @IC/IB=1A/50 ㎃)
• Suitable for low voltage large current drivers
• Complementary pair with DP200F
• Switching Application
Ordering Information
Type NO.
DN200F
Marking
N04
Outline Dimensions
Package Code
SOT-89
unit : mm
PIN Connections
1. Base
2. Collector
3. Emitter
KST-2125-002
1
DN200F
Absolute maximum ratings
(Ta=25°C)
Characteristic
Symbol
Ratings
Unit
Collector-Base voltage
VCBO
15
V
Collector-Emitter voltage
VCEO
12
V
Emitter-Base voltage
VEBO
5
V
IC
2
A
Collector power dissipation
PC
PC*
0.5
2
W
Junction temperature
TJ
150
°C
Storage temperature
Tstg
-55~150
°C
Collector current
* : When mounted on 40×40×0.8mm ceramic substate
Electrical Characteristics
Characteristic
(Ta=25°C)
Symbol
Test Condition
Min. Typ. Max.
Unit
Collector-Base breakdown voltage
BVCBO
IC=50 ㎂, IE=0
15
-
-
V
Collector-Emitter breakdown voltage
BVCEO
IC=1 ㎃, IB=0
12
-
-
V
Emitter-Base breakdown voltage
BVEBO
IE=50 ㎂, IC=0
5
-
-
V
Collector cut-off current
ICBO
VCB=12V, IE=0
-
-
0.1
Emitter cut-off current
IEBO
VEB=5V, IC=0
-
-
0.1
㎂
㎂
hFE1
VCE=1V, IC=100 ㎃
200
-
450
-
hFE2
VCE=1V, IC=2A
40
-
-
-
DC current gain
Collector-Emitter saturation voltage
VCE(sat)
IC=1A, IB=50 ㎃
-
-
0.3
V
Base-Emitter saturation voltage
VBE(sat)
IC=1A, IB=50 ㎃
-
-
1.2
V
fT
VCE=5V, IC=50 ㎃
-
260
-
㎒
VCB=10V, IE=0, f=1 ㎒
-
5
-
㎊
Transition frequency
Collector output capacitance
Cob
KST-2125-002
2
DN200F
Electrical Characteristic Curves
Fig. 2 IC - VBE
㎽
Fig. 1 PC - Ta
Fig. 4 VCE(sat)-IC
㎷
Fig. 3 hFE-IC
㎃
㎃
KST-2125-002
3
DN200F
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.
KST-2125-002
4