DN200F Semiconductor NPN Silicon Transistor Features • Extremely low collector-to-emitter saturation voltage ( VCE(SAT)= 0.2V Typ. @IC/IB=1A/50 ㎃) • Suitable for low voltage large current drivers • Complementary pair with DP200F • Switching Application Ordering Information Type NO. DN200F Marking N04 Outline Dimensions Package Code SOT-89 unit : mm PIN Connections 1. Base 2. Collector 3. Emitter KST-2125-002 1 DN200F Absolute maximum ratings (Ta=25°C) Characteristic Symbol Ratings Unit Collector-Base voltage VCBO 15 V Collector-Emitter voltage VCEO 12 V Emitter-Base voltage VEBO 5 V IC 2 A Collector power dissipation PC PC* 0.5 2 W Junction temperature TJ 150 °C Storage temperature Tstg -55~150 °C Collector current * : When mounted on 40×40×0.8mm ceramic substate Electrical Characteristics Characteristic (Ta=25°C) Symbol Test Condition Min. Typ. Max. Unit Collector-Base breakdown voltage BVCBO IC=50 ㎂, IE=0 15 - - V Collector-Emitter breakdown voltage BVCEO IC=1 ㎃, IB=0 12 - - V Emitter-Base breakdown voltage BVEBO IE=50 ㎂, IC=0 5 - - V Collector cut-off current ICBO VCB=12V, IE=0 - - 0.1 Emitter cut-off current IEBO VEB=5V, IC=0 - - 0.1 ㎂ ㎂ hFE1 VCE=1V, IC=100 ㎃ 200 - 450 - hFE2 VCE=1V, IC=2A 40 - - - DC current gain Collector-Emitter saturation voltage VCE(sat) IC=1A, IB=50 ㎃ - - 0.3 V Base-Emitter saturation voltage VBE(sat) IC=1A, IB=50 ㎃ - - 1.2 V fT VCE=5V, IC=50 ㎃ - 260 - ㎒ VCB=10V, IE=0, f=1 ㎒ - 5 - ㎊ Transition frequency Collector output capacitance Cob KST-2125-002 2 DN200F Electrical Characteristic Curves Fig. 2 IC - VBE ㎽ Fig. 1 PC - Ta Fig. 4 VCE(sat)-IC ㎷ Fig. 3 hFE-IC ㎃ ㎃ KST-2125-002 3 DN200F These AUK products are intended for usage in general electronic equipments(Office and communication equipment, measuring equipment, domestic electrification, etc.). Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic signal, combustion central, all types of safety device, etc.). AUK cannot accept liability to any damage which may occur in case these AUK products were used in the mentioned equipments without prior consultation with AUK. KST-2125-002 4