Issue: 06 Date: 2006-03-16 Specification AXIS50-11 Oscillator type : UHF VCXO with LVPECL or Sinus Output Parameter min. Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range (-20°~+50°C) vs. supply voltage variation vs. load change long term (aging) Long term aging over 10 years Frequency adjustment range Electronic Frequency Control (EFC) range @ 25°C EFC voltage VC EFC slope (∆f / ∆VC) EFC linearity EFC input impedance RF output Signal waveform typ. max. Unit 60 350 MHz 60 / 93.333 / 186.667 / 213.3 MHz / 311.040 ppm ppm ± 10 ppm -0.1 -0.1 -20°C ~ +50°C 0.1 0.1 ±2 ± 10 ppm ppm ppm/year @ 40°C ppm 3.15 ppm ppm V ± 15 0.15 Condition positive 100 SINUS LVPECL Complementary -3 40 % kΩ Option S Option L RL = 50 Ω Amplitude (Option S) dBm Anharmonics attenuation (Option S) dB Output Levels (Option L) -20°C ~ +50°C HIGH (VOH) 2,215 2,345 2,420 V RL = 50 Ω to VS - 2 V LOW (VOL) 1,470 1,595 1,745 V Note 2 3.15 3.3 3.45 V Supply voltage VS Current consumption (steady state) 40 mA -30 +60 °C Operable temperature range -40 +85 °C Storage temperature range 20.5x20.5x10.5 max. mm IEC 60679-3 or 61837 Enclosure (see drawing) 5 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Output parameters vary 1:1 with VS Ordering Code: Model (Specification) AXIS50-11 GmbH & Co. KG Wasemweg 8 D-74821 Mosbach Germany Option Frequency [MHz] S 311.040 AXIS50-11 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections: Pin # Symbol 1 N.C. Q 2 RF OUT 3 GND 4 VC 5 VS Function No Connection (Option S) RF Output ( Q ) (Option L) RF Output (Q) Ground Control Voltage (EFC) Supply Voltage Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 8 D-74821 Mosbach Germany AXIS50-11 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]