AXTAL AXIS50-11

Issue: 06
Date: 2006-03-16
Specification
AXIS50-11
Oscillator type :
UHF VCXO with LVPECL or Sinus Output
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating
temperature range (-20°~+50°C)
vs. supply voltage variation
vs. load change
long term (aging)
Long term aging over 10 years
Frequency adjustment range
Electronic Frequency Control (EFC)
range @ 25°C
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
RF output
Signal waveform
typ.
max.
Unit
60
350
MHz
60 / 93.333 / 186.667 / 213.3 MHz
/ 311.040
ppm
ppm
± 10
ppm
-0.1
-0.1
-20°C ~ +50°C
0.1
0.1
±2
± 10
ppm
ppm
ppm/year @ 40°C
ppm
3.15
ppm
ppm
V
± 15
0.15
Condition
positive
100
SINUS
LVPECL Complementary
-3
40
%
kΩ
Option S
Option L
RL = 50 Ω
Amplitude (Option S)
dBm
Anharmonics attenuation (Option S)
dB
Output Levels (Option L)
-20°C ~ +50°C
HIGH (VOH)
2,215
2,345
2,420
V
RL = 50 Ω to VS - 2 V
LOW (VOL)
1,470
1,595
1,745
V
Note 2
3.15
3.3
3.45
V
Supply voltage VS
Current consumption (steady state)
40
mA
-30
+60
°C
Operable temperature range
-40
+85
°C
Storage temperature range
20.5x20.5x10.5 max.
mm
IEC 60679-3 or 61837
Enclosure (see drawing)
5
gram
Weight
bulk
IEC 60286-3
Packing
1500
V
HBM, IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Output parameters vary 1:1 with VS
Ordering Code:
Model (Specification)
AXIS50-11
GmbH & Co. KG
Wasemweg 8
D-74821 Mosbach
Germany
Option Frequency [MHz]
S
311.040
AXIS50-11
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections:
Pin # Symbol
1
N.C.
Q
2
RF OUT
3
GND
4
VC
5
VS
Function
No Connection (Option S)
RF Output ( Q ) (Option L)
RF Output (Q)
Ground
Control Voltage (EFC)
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 8
D-74821 Mosbach
Germany
AXIS50-11
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836