Issue: 05 Specification AXIOM30 Oscillator type : OCXO Parameter min. typ. max. Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating temperature range (steady state) 10 40 10.000 / 12.800 / 19.440 operating temperature range vs. supply voltage variation vs. load change Long term (aging) per day, after 30 days operation long term (aging) 1st year, after 30 days operation Frequency adjustment range Electronic Frequency Control (EFC) range EFC voltage VC -10 EFC slope (∆f / ∆VC) EFC linearity EFC input impedance RF output Signal waveform Load Rise & decay time Symmetry (duty cycle) Warm-up time Supply voltage VS Unit Condition ± 200 ± 100 ± 50 ± 25 ± 10 60 ± 10 ± 10 ± 10 ±2 ± 200 ± 100 MHz MHz ppm ppb ppb ppb ppb ppb ppb °C ppb ppb ppb ppb ppb ppb Option II = “200”, “100” Option II = “50”,“25”,”10” Option II = “200”, “100” Option II = “50”,“25”,”10” 3.15 4.75 ppm ppm V V Option II = “200”, “100” Option II = “50”,“25”,”10” Option I = “33” Option I = “50” ± 500 ±3 ± 0.8 0.15 0.25 Date: 2006-10-06 ±1 @+25°C, VC= 2.5V Option II = “200” Option II = “100” Option II = “50” Option II = “25” Option II = “10” positive % kΩ 100 HCMOS 15 Current consumption (steady state) @ +25°C Current consumption (warm-up) 10 40 60 5 3.15 3.3 3.45 4.75 5.0 5.25 300 200 800 500 -20 +70 -40 +85 20.5x20.5x12 max. 10 Palette 1500 pF ns % min V V mA mA mA mA °C °C mm gram @ VS/2 ∆ffinal/f0 < ±0.1 ppm Option I = “33” Option I = “50” Option I = “33” Option I = “50” Option I = “33” Option I = “50” Operable temperature range Storage temperature range IEC 60679-3 CO 15 Enclosure (see drawing) L x W x H Weight Packing V HBM as in IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXIOM30 GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany Option I Option II Frequency [MHz] 50 100 10.000 AXIOM30 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections Pin # Symbol 1 VS 2 RF OUT 3 GND 4 VC 5 N.C. Function Supply Voltage RF Output Ground Control Voltage (EFC) No Connection Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIOM30 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]