AXTAL AXIOM20

Issue: 03
Date: 2005-07-15
Specification
AXIOM20
Oscillator type :
OCXO in DIL14 package, HCMOS Output
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature (steady state)
10
operating temperature range
vs. supply voltage variation
vs. load change
long term (aging) 1st year (Note 3)
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
-10
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
RF output
Signal waveform
Load
Rise & decay time
Symmetry
Warm-up time
Supply voltage VS
typ.
Unit
Condition
± 100
± 200
± 300
± 500
+60
± 10
± 20
± 0.5
MHz
MHz
ppm
ppb
ppb
ppb
ppb
ppb
°C
ppb
ppb
ppm
@+25°C, VC= 2.5V
Option II =”100”
Option II =”200”
Option II =”300”
Option II =”500”
Note 2
±5
3.15
4.75
ppm
V
V
80
10 / 12.8 / 16.384
± 500
±2
0.15
0.25
1.65
2.5
positive
HCMOS
15
40
3.13
4.75
@ +40°C, after 30 days
Option I = “33”
Option I =50”
%
kΩ
100
3.3
5.0
Current consumption (steady state)
@ +25°C
Current consumption (warm-up)
Enable/disable function
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
max.
10
60
2
3.47
5.25
300
200
800
500
-30
+75
-40
+85
20.7x13.1x8.5 max.
5
Palette or stick
1500
pF
ns
%
min
V
mA
mA
mA
mA
°C
°C
mm
gram
V
∆ffinal/f0 < ±0.1 ppm
Option I = “33”
Option I =50”
Option I = “33”
Option I =50”
Option I = “33”
Option I =50”
IEC 60679-3 CO 02
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Operating temperature range –20°C to +70°C on request
3. Aging of ± 0.2 ppm / 1st year on request
Ordering Code:
Model (Specification) Option I Option II
AXIOM20
50
100
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Frequency [MHz]
10.000
AXIOM20
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
VC
7
GND
8
RF OUT
14
VS
Function
Voltage Control (EFC)
Ground
RF Output
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
Test conditions
Enclosure styles as in IEC
60679-3 or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Vibration,
sinusoidal*
2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes,
40g, 6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes
of operating temperature range
Test Ba, 16 h at upper
temperature indicated by climatic
category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower
temperature indicated by climatic
category
st
Sequence of 4.6.14, 4.6.15 (1
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM20
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]