AXTAL AXIS60-11

Issue: 03
Specification
AXIS60-11
Oscillator type :
VCXO
Parameter
min.
Frequency range
Standard frequencies
max.
Supply voltage VS
Current consumption (steady state)
Enable/disable function
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Unit
MHz
MHz
64,250
Frequency stability
Initial tolerance
vs. temperature
in operating frequency range 0°~+70°C
(steady state)
vs. supply voltage variation
vs. load change
long term (aging) per year
Frequency adjustment range
Mechanical (internal trimmer)
Electronic Frequency Control (EFC)
range
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
RF output
Signal waveform
Load RL
Level
Harmonics attenuation
Anharmonics attenuation
Phase Noise L(f)
Weight
Packing
ESD Sensitivity
typ.
Date: 2005-07-15
Condition
Other frequencies on
request
-10
-20
10
20
ppm
ppm
ppm
-3
-1
-2
3
1
2
ppm
VS ± 5 %
ppm
RL ± 5 %
ppm/year @ 40°C
ppm
ppm
± 100
0
5,0
V
10
%
kΩ
@+25°C
0°~+70°C
N.A.
positive
1
-2
-20
-40
4.75
SINUS
50
0
-95
-115
-125
-125
5.0
+2
5.25
45
-40
+85
-40
+85
19.1x13.1x5.5 max
3
Ω
dBm
dBc
dBc
dBc
dBc
dBc
dBc
V
mA
°C
°C
mm
@ +25°C
IEC 61837 CO20
modified
gram
Tape & reel
1500
@ 100 Hz
@ 1 kHz
@ 10 kHz
@ 100 kHz
V
IEC 60286-3
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXIS60-11
GmbH & Co. KG
Wasemweg 8
D-74821 Mosbach
Germany
Frequency [MHz]
64,250
AXIS60-11
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
VC
2
GND
4
RF OUT
5
VS
Function
Control Voltage (EFC)
Ground
RF Output
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 8
D-74821 Mosbach
Germany
AXIS60-11
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]