CLARE LCA125

LCA125
Single Pole OptoMOS® Relay
Load Voltage
Load Current
Max RON
LCA125
300
170
16
Description
LCA125 is a 300V, 170mA, 16Ω 1-Form-A relay. It features enhanced peak load current capability with a 300V
peak load voltage. Current limiting version is available.
(“L” suffix)
Units
V
mA
Ω
Features
• Small 6 Pin DIP Package
• Low Drive Power Requirements (TTL/CMOS
Compatible)
• No Moving Parts
• High Reliability
• Arc-Free With No Snubbing Circuits
• 3750VRMS Input/Output Isolation
• FCC Compatible
• VDE Compatible
• No EMI/RFI Generation
• Machine Insertable, Wave Solderable
• Surface Mount and Tape & Reel
Versions Available
Approvals
• UL Recognized: File Number E76270
• CSA Certified: File Number LR 43639-10
• BSI Certified to:
• BS EN 60950:1992 (BS7002:1992)
Certificate #: 7344
• BS EN 41003:1993
Certificate #: 7344
Ordering Information
Applications
• Telecommunications
• Telecom Switching
• Tip/Ring Circuits
• Modem Switching (Laptop, Notebook, Pocket Size)
• Hookswitch
• Dial Pulsing
• Ground Start
• Ringer Injection
• Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• Medical Equipment-Patient/Equipment Isolation
• Security
• Aerospace
• Industrial Controls
Part #
LCA125
LCA125S
LCA125STR
Description
6 Pin DIP (50/Tube)
6 Pin Surface Mount (50/Tube)
6 Pin Surface Mount (1000/Reel)
Pin Configuration
LCA125/LCA125L Pinout
LCA125/125L Pinout
AC/DC Configuration
DC Only Configuration
+ Control
– Control
Do Not Use
1
6
2
5
3
4
+ Control
Load
– Control
Do Not Use
Do Not Use
Load
1
6
2
5
3
4
+ Load
– Load
Switching Characteristics of
Normally Open (Form A) Devices
10ms
CONTROL
LOAD 10%+
+90%
TON
DS-LCA125-R8
www.clare.com
10%+
TOFF
1
LCA125
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Min
Input Power Dissipation
-
-
1501
mW
Input Control Current
Peak (10ms)
-
-
50
1
mA
A
Reverse Input Voltage
-
-
5
V
Total Power Dissipation
-
-
8002
mW
Isolation Voltage
Input to Output
3750
-
-
VRMS
Operational Temperature
-40
-
+85
°C
Storage Temperature
-40
-
+125
°C
-
-
+260
+220
°C
°C
Soldering Temperature
DIP Package
Surface Mount Package
(10 Seconds Max.)
1
Derate Linearly 1.33 mw/˚C
2
Derate Linearly 6.67 mw/˚C
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Typ Max Units
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Load Voltage (Peak)
-
VL
-
-
300
V
Load Current (Continuous)
AC/DC Configuration
DC Configuration
-
IL
IL
-
-
170
300
mA
mA
10ms
IL
-
-
400
mA
IL=170mA
IL=300mA
RON
RON
-
10
4
16
5
Ω
Ω
Output Characteristics @ 25°C
Peak Load Current
On-Resistance
AC/DC Configuration
DC Configuration
Off-State Leakage Current
VL=300V
ILEAK
-
-
1
µA
Switching Speeds
Turn-On
Turn-Off
IF=5mA, VL=10V
IF=5mA, vL=10V
TON
TOFF
-
-
5
5
ms
ms
Output Capacitance
50V; f=1MHz
COUT
-
50
-
-pF
Input Control Current
IL=170mA
IF
5
-
50
mA
Input Dropout Current
-
-
0.4
0.7
-
mA
Input Characteristics @ 25°C
Input Voltage Drop
2
IF=5mA
VF
0.9
1.2
1.4
V
Reverse Input Voltage
-
VR
-
-
5
V
Reverse Input Current
VR=5V
IR
-
-
10
µA
Input to Output Capacitance
-
CI/O
-
3
-
pF
Input to Output Isolation
-
VI/O
3750
-
-
VRMS
www.clare.com
Rev. 8
LCA125
PERFORMANCE DATA*
Device Count (N)
25
20
15
10
30
25
25
20
20
15
10
5
5
0
1.19
1.21
1.23
1.25
8.25
8.75
LED Forward Voltage (V)
5
9.75
10.25
302.5
20
20
20
5
Device Count (N)
25
10
15
10
5
0
0.42
0.54
0.66
0.78
0.18
0.30
LED Current (mA)
20
250
Load Current (mA)
300
15
10
5
0
0.42
0.54
0.66
0.10
0.14
0.18
0.22
5
0.78
0.875 1.225 1.575 1.925 2.275 2.625 2.975
Turn-On (ms)
LCA125
Typical Leakage vs. Temperature
(Measured across Pins 4 & 6)
200
150
20mA
10mA
5mA
100
50
0
0.06
0.26
0.30
-40
-20
0
20
40
60
80
100
120
0.100
0.090
0.080
0.070
0.060
0.050
0.040
0.030
0.020
0.010
0
-40
-20
0
3.0
335
2.5
40
60
80
100
LCA125
Typical Turn-Off vs. Temperature
(Load Current = 170mADC)
LCA125
Typical Turn-On vs. Temperature
(Load Current = 170mADC)
LCA125
Typical Blocking Voltage vs. Temperature
20
Temperature (°C)
Temperature (°C)
Turn-Off (ms)
340
347.5
10
LCA125
Typical Load Current vs. Temperature
25
338.5
15
LED Current (mA)
LCA125
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
338.5
0
0.90
Leakage (µA)
0.30
320.5
LCA125
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
25
15
311.5
Blocking Voltage (V)
25
Device Count (N)
Device Count (N)
9.25
LCA125
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
0
Device Count (N)
10
On-Resistance (Ω)
LCA125
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
0.300
0.250
5mA
330
Turn-On (ms)
Blocking Voltage (VRMS)
15
0
0
1.17
325
320
315
2.0
1.5
10mA
1.0
20mA
310
0.5
305
0
Turn-Off (ms)
Device Count (N)
30
LCA125
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
Device Count (N)
35
LCA125
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 5mADC)
LCA125
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 5mADC
0.200
0.150
0.100
0.050
5mA
-40
-20
0
20
40
60
Temperature (°C)
80
100
0
-40
-20
0
20
40
60
80
Temperature (°C)
100
-40
-20
0
20
40
60
80
100
Temperature (°C)
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
Rev. 8
www.clare.com
3
LCA125
PERFORMANCE DATA*
50mA
30mA
20mA
10mA
5mA
1.2
1.0
0.8
-40
-20
0
20
40
60
80
100
0.12
0.10
0.08
0.06
0.04
0.02
0
5
10
15
20
25
30
35
40
45
0
50
5
10
15
20
25
30
35
40
45
LED Forward Current (mA)
LED Forward Current (mA)
LCA125
Typical On-Resistance vs. Temperature
(Load Current = 170mADC; IF = 5mADC)
LCA125
Typical IF for Switch Operation
vs. Temperature
(Load Current = 170mADC)
LCA125
Typical IF for Switch Dropout
vs. Temperature
(Load Current = 170mADC)
40.000
30.000
20.000
10.000
1.800
1.8
1.600
1.6
1.400
1.4
Current (mA)
LED Current (mA)
On-Resistance (Ω)
0.14
Temperature (°C)
50.000
1.200
1.000
0.800
0.600
0.400
-20
0
20
40
60
80
LCA125
Typical Load Current vs. Load Voltage
(Ambient Temperature = 25°C)
IF = 5mADC
0.8
0.6
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
Temperature (°C)
LCA125
Energy Rating Curve
1.2
150
1.0
Load Current (A)
100
50
0
-50
-100
0.8
0.6
0.4
0.2
-150
-200
-2.0
-20
Temperature (°C)
Temperature (°C)
1.0
0
-40
100
1.2
0.2
0
-40
50
0.4
0.200
0
Load Current (mA)
0.16
0
120
60.000
200
0.18
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
Turn-Off (ms)
1.6
Turn-On (ms)
LED Forward Voltage Drop (V)
1.8
1.4
LCA125
Typical Turn-Off vs. LED Forward Current
(Load Current = 170mADC)
LCA125
Typical Turn-On vs. LED Forward Current
(Load Current = 170mADC)
LCA125
Typical LED Forward Voltage Drop
vs. Temperature
-1.5 -1.0 -0.5
0
0.5
Load Voltage (V)
1.0
1.5
2.0
0
10µs 100µs 1ms 10ms 100ms
1s
10s 100s
Time
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
4
www.clare.com
Rev. 8
LCA125
Mechanical Dimensions
8.382 ± .635
(.330 ± .025)
6 Pin DIP Through Hole (Standard)
2.540 ± .127
(.100 ± .005)
7.620 ± .254
(.300 ± .010)
7.239 TYP.
(.285)
3.302
(.130)
6.350 ± .127
(.250 ± .005)
9.144 ± .508
(.360 ± .020)
.635 TYP.
(.025)
5.080 ± .127
(.200 ± .005)
PC Board Pattern
(Top View)
2.540 ± .127
2.540 ± .127
(.100 ± .005)
(.100 ± .005)
9.525 ± .254
(.375 ± .010)
6.350 ± .127
(.250 ± .005)
3.302
(.130)
7.620 ± .127
(.300 ± .005)
6.350 ± .127
(.250 ± .005)
9.144
(.360)
8.382 ± .635
(.330 ± .025)
7.620 ± .254
(.300 ± .010)
2.540 ± .127
(.100 ± .005)
6-.800 DIA.
(6-.031 DIA.)
.457 ± .076
(.018 ± .003)
6 Pin DIP Surface Mount (“S” Suffix)
4.445 ± .127
(.175 ± .005)
PC Board Pattern
(Top View)
8.305 ± .127
(.327 ± .005)
1.905 ± .127
(.075 ± .005)
.254 TYP.
(.010)
.457 ± .076
(.018 ± .003)
1.499 ± .127
(.059 ± .005)
Tape and Reel Packaging for 6 Pin Surface Mount Package
330.2 DIA.
(13.00)
Top Cover
Tape Thickness
.102 MAX.
(.004)
6.731 MAX.
1.753 ± .102
(.265)
(.069 ± .004)
.406 MAX.
(.016)
2.007 ± .102 1.498 ± .102 3.987 ± .102
(.079 ± .004) (.059 ± .004) (.157 ± .004)
7.493 ± .102
(.295 ± .004)
1
6
12.090
(.476)
10.100
(.398)
4.877
(.192)
Top Cover
Tape
Embossed Carrier
16.002 ± .305
(.630 ± .012)
.050R TYP.
11.989 ± .102
(.472 ± .004)
10.100 ± .102
(.398 ± .004)
1.549 ± .102
(.061 ± .004)
User Direction of Feed
Embossment
Dimensions
mm
(inches)
Rev. 8
www.clare.com
5
For additional information please visit our website at: www.clare.com
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions
at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and
disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or
make changes to its products at any time without notice.
Specification: DS-LCA125-R8.0
©Copyright 2002, Clare, Inc.
All rights reserved. Printed in USA.
7/10/02