DIOTEC P6KE24A

P6 KE 6.8 ... P6 KE 440CA, P6 KE 520C
Unidirectional and bidirectional
Transient Voltage Suppressor Diodes
Unidirektionale und bidirektionale
Spannungs-Begrenzer-Dioden
Peak pulse power dissipation
Impuls-Verlustleistung
600 W
Nominal breakdown voltage
Nominale Abbruch-Spannung
Plastic case – Kunststoffgehäuse
6.8...520 V
DO-15 (DO-204AC)
Weight approx. – Gewicht ca.
0.4 g
Plastic material has UL classification 94V-0
Gehäusematerial UL94V-0 klassifiziert
Dimensions / Maße in mm
Standard packaging taped in ammo pack
Standard Lieferform gegurtet in Ammo-Pack
see page 16
siehe Seite 16
For bidirectional types (suffix “C” or “CA”), electrical characteristics apply in both directions.
Für bidirektionale Dioden (Suffix “C” oder “CA”) gelten die el. Werte in beiden Richtungen.
Maximum ratings and Characteristics
Kenn- und Grenzwerte
Peak pulse power dissipation (10/1000 :s waveform)
Impuls-Verlustleistung (Strom-Impuls 10/1000 :s)
TA = 25/C
PPPM
Steady state power dissipation
Verlustleistung im Dauerbetrieb
TA = 25/C
PM(AV)
Peak forward surge current, 60 Hz half sine-wave
Stoßstrom für eine 60 Hz Sinus-Halbwelle
TA = 25/C
IFSM
Operating junction temperature – Sperrschichttemperatur
Storage temperature – Lagerungstemperatur
Max. instantaneous forward voltage
Augenblickswert der Durchlaßspannung
IF = 50 A
VBR # 200 V
VBR > 200 V
600 W 1)
5 W 2)
100 A 3)
Tj
TS
– 50…+175/C
– 50…+175/C
VF
VF
< 3.5 V 3)
< 5.0 V 3)
Thermal resistance junction to ambient air
Wärmewiderstand Sperrschicht – umgebende Luft
RthA
< 30 K/W 2)
Thermal resistance junction to lead
Wärmewiderstand Sperrschicht – Anschlußdraht
RthL
< 15 K/W
1
) Non-repetitive current pulse see curve IPPM = f (tr)
Höchstzulässiger Spitzenwert eines einmaligen Strom-Impulses, siehe Kurve IPPM = f (tr)
2
) Valid, if leads are kept at ambient temperature at a distance of 10 mm from case
Gültig, wenn die Anschlußdrähte in 10 mm Abstand von Gehäuse auf Umgebungstemperatur gehalten werden
3
) Unidirectional diodes only – Nur für unidirektionale Dioden
25.03.2003
1
P6 KE 6.8 ... P6 KE 440CA, P6 KE 520C
Maximum ratings
Type
Typ
P6 KE6.8
P6 KE6.8A
P6 KE7.5
P6 KE7.5A
P6 KE8.2
P6 KE8.2A
P6 KE9.1
P6 KE9.1A
P6 KE10
P6 KE10A
P6 KE11
P6 KE11A
P6 KE12
P6 KE12A
P6 KE13
P6 KE13A
P6 KE15
P6 KE15A
P6 KE16
P6 KE16A
P6 KE18
P6 KE18A
P6 KE20
P6 KE20A
P6 KE22
P6 KE22A
P6 KE24
P6 KE24A
P6 KE27
P6 KE27A
P6 KE30
P6 KE30A
P6 KE33
P6 KE33A
P6 KE36
P6 KE36A
P6 KE39
P6 KE39A
P6 KE43
P6 KE43A
P6 KE47
P6 KE47A
P6 KE51
P6 KE51A
2
Grenzwerte
Breakdown voltage at IT = 1 mA
Abbruch-Spanng. bei IT = 1 mA
*) at / bei IT = 10 mA
Stand-off
voltage
Sperrspg.
Max. rev. current
Max. Sperrstrom
at / bei VWM
VBR [V]
VWM [V]
ID [:A]
VC [V]
IPPM [A]
5.5
5.8
6.0
6.4
6.6
7.0
7.3
7.7
8.1
8.5
8.9
9.4
9.7
10.2
10.5
11.1
12.1
12.8
12.9
13.6
14.5
15.3
16.2
17.1
17.8
18.8
19.4
20.5
21.8
23.1
24.3
25.6
26.8
28.2
29.1
30.8
31.6
33.3
34.8
36.8
38.1
40.2
41.3
43.6
1000
1000
500
500
200
200
50
50
10
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
10.8
10.5
11.7
11.3
12.5
12.1
13.8
13.4
15.0
14.5
16.2
15.6
17.3
16.7
19.0
18.2
22.0
21.2
23.5
22.5
26.5
25.5
29.1
27.7
31.9
30.6
34.7
33.2
39.1
37.5
43.5
41.4
47.7
45.7
52.0
49.9
56.4
53.9
61.9
59.3
67.8
64.8
73.5
70.1
58.0
60.0
53.0
55.0
50.0
52.0
45.0
47.0
42.0
43.0
38.0
40.0
36.0
37.0
33.0
34.0
28.0
29.0
26.0
28.0
23.0
25.0
21.0
22.0
19.0
20.0
18.0
19.0
16.0
16.8
14.0
15.0
13.0
13.8
12.0
12.6
11.1
11.6
10.0
10.6
9.2
9.7
8.5
8.9
6.8 ± 10%
6.8 ± 5%
7.5 ± 10%
7.5 ± 5%
8.2 ± 10%
8.2 ± 5%
9.1 ± 10%
9.1 ± 5%
10 ± 10%
10 ± 5%
11 ± 10%
11 ± 5%
12 ± 10%
12 ± 5%
13 ± 10%
13 ± 5%
15 ± 10%
15 ± 5%
16 ± 10%
16 ± 5%
18 ± 10%
18 ± 5%
20 ± 10%
20 ± 5%
22 ± 10%
22 ± 5%
24 ± 10%
24 ± 5%
27 ± 10%
27 ± 5%
30 ± 10%
30 ± 5%
33 ± 10%
33 ± 5%
36 ± 10%
36 ± 5%
39 ± 10%
39 ± 5%
43 ± 10%
43 ± 5%
47 ± 10%
47 ± 5%
51 ± 10%
51 ± 5%
6.12...7.48 *)
6.45...7.14 *)
6.75...8.25 *)
7.13...7.88 *)
7.38...9.02 *)
7.79...8.61 *)
8.19...10.0
8.65...9.55
9.0...11.0
9.5...10.5
9.9...12.1
10.5...11.6
10.8...13.2
11.4...12.6
11.7...14.3
12.4...13.7
13.5...16.5
14.3...15.8
14.4...17.6
15.2...16.8
16.2...19.8
17.1...18.9
18.0...22.0
19.0...21.0
19.8...24.2
20.9...23.1
21.6...26.4
22.8...25.2
24.3...29.7
25.7...28.4
27.0...33.0
28.5...31.5
29.7...36.3
31.4...34.7
32.4...39.6
34.2...37.8
35.1...42.9
37.1...41.0
38.7...47.3
40.9...45.2
42.3...51.7
44.7...49.4
45.9...56.1
48.5...53.6
Max. clamping voltage
Max. Begrenzerspanng.
at / bei IPPM (10/1000:s)
P6 KE 6.8 ... P6 KE 440CA, P6 KE 520C
Maximum ratings
Type
Typ
P6KE56
P6 KE56A
P6 KE62
P6 KE62A
P6 KE68
P6 KE68A
P6 KE75
P6 KE75A
P6 KE82
P6 KE82A
P6 KE91
P6 KE91A
P6 KE100
P6 KE100A
P6 KE110
P6 KE110A
P6 KE120
P6 KE120A
P6 KE130
P6 KE130A
P6 KE150
P6 KE150A
P6 KE160
P6 KE160A
P6 KE170
P6 KE170A
P6 KE180
P6 KE180A
P6 KE200
P6 KE200A
P6 KE220
P6 KE220A
P6 KE250
P6 KE250A
P6 KE300
P6 KE300A
P6 KE350
P6 KE350A
P6 KE400
P6 KE400A
P6 KE440
P6 KE440A
P6 KE520C 1)
Grenzwerte
Breakdown voltage at IT = 1 mA
Abbruch-Spanng. bei IT = 1 mA
*) at / bei IT = 10 mA
Stand-off
voltage
Sperrspg.
Max. rev. current
Max. Sperrstrom
at / bei VWM
VBR [V]
VWM [V]
ID [:A]
VC [V]
IPPM [A]
45.4
47.8
50.2
53.0
55.1
58.1
60.7
64.1
66.4
70.1
73.7
77.8
81.0
85.5
89.2
94.0
97.2
102
105
111
121
128
130
136
138
145
146
154
162
171
175
185
202
214
243
256
284
300
324
342
356
376
423
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
80.5
77.0
89.0
85.0
98.0
92.0
108
103
118
113
131
125
144
137
158
152
173
165
187
179
215
207
230
219
244
234
258
246
287
274
344
328
360
344
430
414
504
482
574
548
631
602
745
7.8
8.1
7.0
7.4
6.4
6.8
5.8
6.1
5.3
5.5
4.8
5.0
4.3
4.5
3.9
4.1
3.6
3.8
3.3
3.5
2.9
3.0
2.7
2.8
2.5
2.6
2.4
2.5
2.1
2.2
1.8
1.9
1.7
1.8
1.4
1.5
1.2
1.3
1.0
1.1
0.99
1.04
0.81
56 ± 10%
56 ± 5%
62 ± 10%
62 ± 5%
68 ± 10%
68 ± 5%
75 ± 10%
75 ± 5%
82 ± 10%
82 ± 5%
91 ± 10%
91 ± 5%
100 ± 10%
100 ± 5%
110 ± 10%
110 ± 5%
120 ± 10%
120 ± 5%
130 ± 10%
130 ± 5%
150 ± 10%
150 ± 5%
160 ± 10%
160 ± 5%
170 ± 10%
170 ± 5%
180 ± 10%
180 ± 5%
200 ± 10%
200 ± 5%
220 ± 10%
220 ± 5%
250 ± 10%
250 ± 5%
300 ± 10%
300 ± 5%
350 ± 10%
350 ± 5%
400 ± 10%
400 ± 5%
440 ± 10%
440 ± 5%
520 ± 10%
50.4...61.6
53.2...58.8
55.8...68.8
58.9...65.1
61.2...74.8
64.6...71.4
67.5...82.5
71.3...78.8
73.8...90.2
77.9...86.1
81.9...100
86.5...95.5
90.0...110
95.0...105
99.0...121
105...116
108...132
114...126
117...143
124...137
135...165
143...158
144...176
152...168
153...187
162...179
162...198
171...189
180...220
190...210
198...242
209...231
225...275
237...263
270...330
285...315
315...385
332...368
360...440
380...420
396...484
418...462
470...570
Max. clamping voltage
Max. Begrenzerspanng.
at / bei IPPM (10/1000:s)
1
) Available only bidirectional version - nur bidirectionale Ausführung lieferbar
25.03.2003
3
P6 KE 6.8 ... P6 KE 440CA, P6 KE 520C
1
The order of type numbers is graded to the international E 24 standard. The standard tolerance of
the breakdown voltage for each type is ± 10%. Suffix “A” denotes a tolerance of ± 5%.
e.g.: P6KE160CA = bidirectional diode, VBR = 160 V (± 5%), VWM $ 136 V at ID = 5 :A
P6KE7.5A = unidirectional diode, VBR = 7.5 V (± 5%), VWM $ 6.4 V at ID = 500 :A
Die Abstufung der Typen innerhalb der Reihe entspricht dem internationalen E 24-Standard. Die
Toleranz der Arbeitsspannung jedes einzelnen Typs beträgt in der Standardausführung ± 10%.
Suffix “A” kennzeichnet eine Toleranz von ± 5%.
z.B.: P6KE160CA = bidirectionale Diode, VBR = 160 V (± 5%), VWM $ 136 V at ID = 5 :A
P6KE7.5A = unidirectionale Diode, VBR = 7.5 V (± 5%), VWM $ 6.4 V at ID = 500 :A
1
) Valid, if leads are kept at ambient temperature at a distance of 10 mm from case
Gültig, wenn die Anschlußdrähte in 10 mm Abstand von Gehäuse auf Umgebungstemperatur gehalten werden
4
F:\Data\WP\DatBlatt\Einzelblätter\p6ke6.8.wpd