Series PCV Analog Input Power Controller • • • • Operates at 60Hz & 50Hz Internal Snubber Industry Standard Package Control Circuit Requires No Adjustment or Calibration MODEL NUMBERS The PCV Series proportional controllers are self contained power control modules integrating a complete phase fired logic control system and a solid state relay in the same standard package. Typical applications include heaters, vibratory feeders and tungsten lamps. 7PCV2415 7PCV2425 10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490 OUTPUT SPECIFICATIONS➀ 100-240 100-240 100-240 100-240 100-240 .15-15 .15-25 .15-50 .15-75 .15-90 Transient Overvoltage [Vpk] 600 600 600 600 600 Max. Surge Current, (1 Cycle) [Apk] 150 250 625 1000 1200 Max. Off-State Leakage Current @ Rated Voltage [mA] 10 15 20 20 20 Maximum I 2 t for Fusing (8.3 msec) [A 2sec] 94 260 1620 4150 6000 Maximum Voltage Drop (100% On) [Vpk] 1.6 1.6 1.6 1.6 1.6 Minimum Off-State dv/dt [V/µsec] 200 200 200 200 200 Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5 0.5 Operating Voltage (47-63 Hz) [Vrms] Max. Load Current Range [Arms] INPUT SPECIFICATIONS ➀ 7PCV24xx 10PCV24xx 2-7 Vdc 2-10 Vdc 4 mA 4 mA Control Voltage Range Typical Input Current @ 5 Vdc GENERAL NOTES All parameters at 25º C unless otherwise specified. TYPICAL APPLICATIONS • Industrial Temperature Controllers • Light Dimming • Vibratory Feeders • Resistive Heating Elements • Conveyor Speed Control UNSUITABLE APPLICATIONS The PCV is not suitable for some load applications including, but not limited to the following: • • • • Percentage On vs. Input Voltage 100 80 Percentage ON ➀ © 2002 CRYDOM CORP, Specifications subject to change without notice. 60 40 50 Hz AC Motor Control Three Phase Motors Transformers requiring pure sine wave input Zero Crossing Applications Please contact Crydom’s application engineering department for additional information and specific application questions. FastFax Document No. 204 SERIES PCV. Rev. 041902 PAGE 1 OF 2 60 Hz 20 0 2.5 3.5 4.5 5.5 6.5 7.5 Input Voltage For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506 8.5 9.5 Series PCV Analog Input Power Controller GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load 2500 Vrms Dielectric Strength, Signal to Base 2500 Vrms Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.5 oz. (100g) Encapsulation: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted Terminals: W IRING DIAGRAM 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. ~ OUTPUT 1 1.87 (47.5) 1 OUTPUT 2 4 + 4 All dimensions are in inches (millimeters) Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) 2.30 (58.4) 1.70 (43.2) 2 SOLID-STATE RELAY -PROPORTIONAL CONTROLLER 8-32 TERMINAL (2 PLACES ) 3 INPUT 3 INPUT 1.00 (25.4) 1.80 (45.7) -- + 6-32 TERMINAL (2 PLACES) .78 (19.8) .90 (22.9) 25A 15A 30 15 2˚C/W 5 6˚C/W 116 NO HEATSINK 120 25 Power Dissipation 4˚C/W 10 Base Plate Temp [˚C] Power Dissipation CURRENT DERATING CURVES 95 1˚C/W 112 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 Base Plate Temp [˚C] BASE PLATE .125 (3.2) 120 124 0 0 6 9 12 15 Load Current [Arms] 50A 40 60 5 80 .5˚C/W 110 20 95 .3˚C/W .5˚C/W 100 60 1˚C/W 110 30 0 50 20 40 60 80 Max Ambient Temp. [˚C] 40 60 80 90 .2˚C/W .4˚C/W 80 100 1˚C/W 110 40 120 120 120 NO HEATSINK 0 Power Dissipation 100 2˚C/W 40 20 Max Ambient Temp. [˚C] 120 Base Plate Temp [˚C] 40 30 25 .5˚C/W Power Dissipation 1.5˚C/W 20 20 90 Base Plate Temp [˚C] 1˚C/W Load Current [Arms] 15 90A 90 10 10 Load Current [Arms] 75A 60 Power Dissipation 20 Max Ambient Temp. [˚C] Base Plate Temp [˚C] 3 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] ©2002 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 204 SERIES PCV. Rev. 041902 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: [email protected] WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected]. GERMANY: +49 (0)180 3000 506