ETC 10PCV2450

Series PCV
Analog Input Power Controller
•
•
•
•
Operates at 60Hz & 50Hz
Internal Snubber
Industry Standard Package
Control Circuit Requires No
Adjustment or Calibration
MODEL NUMBERS
The PCV Series proportional controllers
are self contained power control modules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
7PCV2415 7PCV2425
10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
OUTPUT SPECIFICATIONS➀
100-240
100-240
100-240
100-240
100-240
.15-15
.15-25
.15-50
.15-75
.15-90
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (1 Cycle) [Apk]
150
250
625
1000
1200
Max. Off-State Leakage Current @ Rated Voltage [mA]
10
15
20
20
20
Maximum I 2 t for Fusing (8.3 msec) [A 2sec]
94
260
1620
4150
6000
Maximum Voltage Drop (100% On) [Vpk]
1.6
1.6
1.6
1.6
1.6
Minimum Off-State dv/dt [V/µsec]
200
200
200
200
200
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current Range [Arms]
INPUT SPECIFICATIONS ➀
7PCV24xx
10PCV24xx
2-7 Vdc
2-10 Vdc
4 mA
4 mA
Control Voltage Range
Typical Input Current @ 5 Vdc
GENERAL NOTES
All parameters at 25º C unless otherwise specified.
TYPICAL APPLICATIONS
• Industrial Temperature Controllers
• Light Dimming
• Vibratory Feeders
• Resistive Heating Elements
• Conveyor Speed Control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
•
•
•
•
Percentage On vs. Input Voltage
100
80
Percentage ON
➀
© 2002 CRYDOM CORP, Specifications subject to change without notice.
60
40
50 Hz
AC Motor Control
Three Phase Motors
Transformers requiring pure sine wave input
Zero Crossing Applications
Please contact Crydom’s application
engineering department for additional
information and specific application
questions.
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 1 OF 2
60 Hz
20
0
2.5
3.5
4.5
5.5
6.5
7.5
Input Voltage
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506
8.5
9.5
Series PCV
Analog Input Power Controller
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
2500 Vrms
Dielectric Strength, Signal to Base
2500 Vrms
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.5 oz. (100g)
Encapsulation:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
Terminals:
W IRING DIAGRAM
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
~
OUTPUT
1
1.87
(47.5)
1 OUTPUT 2
4
+
4
All dimensions are in inches (millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
2.30
(58.4)
1.70
(43.2)
2
SOLID-STATE RELAY
-PROPORTIONAL
CONTROLLER
8-32 TERMINAL
(2 PLACES )
3
INPUT
3
INPUT
1.00
(25.4)
1.80
(45.7)
--
+
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
25A
15A
30
15
2˚C/W
5
6˚C/W
116
NO HEATSINK
120
25
Power Dissipation
4˚C/W
10
Base Plate Temp [˚C]
Power Dissipation
CURRENT DERATING CURVES
95
1˚C/W
112
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
Base Plate Temp [˚C]
BASE PLATE
.125 (3.2)
120
124
0
0
6
9
12
15
Load Current [Arms]
50A
40
60
5
80
.5˚C/W
110
20
95
.3˚C/W
.5˚C/W
100
60
1˚C/W
110
30
0
50
20
40
60
80
Max Ambient Temp. [˚C]
40
60
80
90
.2˚C/W
.4˚C/W
80
100
1˚C/W
110
40
120
120
120
NO HEATSINK
0
Power Dissipation
100
2˚C/W
40
20
Max Ambient Temp. [˚C]
120
Base Plate Temp [˚C]
40
30
25
.5˚C/W
Power Dissipation
1.5˚C/W
20
20
90
Base Plate Temp [˚C]
1˚C/W
Load Current [Arms]
15
90A
90
10
10
Load Current [Arms]
75A
60
Power Dissipation
20
Max Ambient Temp. [˚C]
Base Plate Temp [˚C]
3
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
©2002 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: [email protected] WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: [email protected].
GERMANY: +49 (0)180 3000 506