ETC H12CD4850

Series H12
25-90Amp • 480 Vac • AC Output
• 1200 Volt Blocking
High voltage relays use IC driven circuits for switching loads up to 660
VAC. All models come with 1200
Volts blocking and are available with
either AC or DC input (coil) control.
Types H12CA, H12CD and H12WD are
snubberless (reduced leakage current).
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
• Panel Mount
• Up to 660 Vac
• Zero Voltage Switching
and Random Turn-On
• SCR Output
MODEL NUMBERS
DC CONTROL
H12CD4850 H12CD4890
H12WD4850 H12WD4890
A C C ONTROL H12CA4850 H12CA4890
H12D4825 H12D4850
H12D4875 H12D4890
OUTPUT SPECIFICATIONS ➀
48-660
48-660
48-530
48-530
48-530
48-530
Max. Load Current ➂ [Arms]
50
90
25
50
75
90
Min. Load Current, [mArms]
150
150
150
150
150
150
Transient Overvoltage [Vpk]
1200
1200
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
625
1200
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC) [˚C/W]
.63
.28
1.02
.63
.31
.28
1620
6000
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
1.0
1.0
10
10
10
10
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
500
500
500
500
500
500
0.5
0.5
Operating Voltage (47-63 Hz) [Vrms]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Turn-On Time ➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time
1/2 Cycle (DC Control), 40.0 msec (AC Control)
Power Factor (Min.) with Max. Load
0.5
INPUT SPECIFICATIONS ➀
0.5
0.5
DC CONTROL
0.5
AC CONTROL
(H12CD PREFIX)
(H12WD & H12D PREFIX)
(H12CA PREFIX)
Control Voltage Range
4-8 Vdc
4-32Vdc
90-140 Vrms (60Hz)
Max. Turn-On Voltage
4.0 Vdc
4.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
10.0 Vrms
220 Ohms
See Note 5
8K Ohms
15 mA @ 5 Vdc ➄
15 mA @ 120 Vrms
Nominal Input Impedance
Typical Input Current
15 mA @ 5 Vdc
©1998 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for DC control random turn-on versions is 0.02 msec.
➄ Input circuitry incorporates active current limiter.
FastFax Document No.157
SERIES H12.081898, PAGE 1 OF 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]
Series H12
25-90Amp • 480 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom’s Heat Sink specification sheet
for all the details.
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
1.87
(47.5)
1.10
(27.9)
.45
(11.4)
8-32 TERMINAL
(2 PLACES )
OUTPUT
2
SOLID-STATE RELAY
-4
Available Options
F
Faston Terminals
(Up to 50 Amp Models)
-10
Random Turn-On
Example: H12WD4850-10
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
3
INPUT
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
+
OUTPUT
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
2
1.87
(47.5)
2.30
(58.4)
1.70
(43.2)
4
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
INPUT
1.00
(25.4)
1.80
(45.7)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
©1998 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
E116949
CSA LR81689
VDE 10143 UG
FastFax Document No.157
SERIES H12.081898, PAGE 2 OF 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]
Series H12
25-90Amp • 480 Vac • AC Output
CURRENT DERATING CURVES
25A
50A
95
60
1ºC/W
2ºC/W
20
15
110
10
NO HEATSINK
5
Power Dissipation
.5ºC/W
90
1.5ºC/W
40
100
2ºC/W
110
20
120
120
NO HEATSINK
0
5
10
15
20
25
Load Current [Arms]
20
40
60
0
80
10
Max Ambient Temp. [ºC]
20
30
40
50
Load Current [Arms]
20
40
60
90A
75A
90
120
120
100
80
1ºC/W
110
40
Power Dissipation
95
.3ºC/W
.5ºC/W
Base Plate Temp [ºC]
.5ºC/W
Power Dissipation
80
Max Ambient Temp. [ºC]
.2ºC/W
.4ºC/W
80
100
1ºC/W
110
40
Base Plate Temp [ºC]
Power Dissipation
100
3ºC/W
Base Plate Temp [ºC]
1ºC/W
25
Base Plate Temp [ºC]
30
120
120
0
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [ºC]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [ºC]
©1998 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.157
SERIES H12.032698, PAGE 3 OF 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]