IXYS DSEP2X35-06C

DSEP 2x 35-06C
Advanced Technical Information
HiPerFREDTM Epitaxial Diode
IFAV = 2x 35 A
VRRM = 600 V
trr
= 20 ns
with soft recovery
VRSM
VRRM
V
V
600
600
miniBLOC, SOT-227 B
Type
DSEP 2x 35-06C
Symbol
Test Conditions
IFRMS
IFAVM
IFRM
TC = 80°C; rectangular, d = 0.5
tP < 10 µs; rep. rating, pulse width limited by TVJM
49
35
tbd
A
A
A
IFSM
TVJ = 45°C; tp = 10 ms (50 Hz), sine
300
A
EAS
TVJ = 25°C; non-repetitive
IAS = 3 A; L = 180 µH
1.2
mJ
IAR
VA = 1.5·VR typ.; f = 10 kHz; repetitive
0.3
A
-40...+150
150
-40...+150
°C
°C
°C
165
W
2500
V~
TVJ
TVJM
Tstg
Maximum Ratings
Features
●
●
●
●
●
●
●
Ptot
TC = 25°C
VISOL
50/60 Hz, RMS
IISOL ≤ 1 mA
Md
mounting torque (M4)
terminal connection torque (M4)
Weight
typical
1.1-1.5/9-13
1.1-1.5/9-13
30
Nm/lb.in.
Nm/lb.in.
●
●
Applications
●
g
●
●
Symbol
IR
①
VF ②
RthJC
RthCH
Test Conditions
Characteristic Values
typ.
max.
VR = VRRM; TVJ = 25°C
TVJ = 150°C
0.25
1.0
mA
mA
IF = 35 A;
1.83
2.50
V
V
0.9
TVJ = 150°C
TVJ = 25°C
with heatsink compound
0.1
K/W
K/W
trr
IF = 1 A; -di/dt = 300 A/µs;
VR = 30 V; TVJ = 25°C
20
ns
IRM
VR = 100 V; IF = 50 A; -diF/dt = 100 A/µs
TVJ = 100°C
4.5
7.0
Pulse test: ① Pulse Width = 5 ms, Duty Cycle < 2.0 %
② Pulse Width = 300 µs, Duty Cycle < 2.0 %
A
International standard package
miniBLOC
Isolation voltage 2500 V~
UL registered E 72873
2 independent FRED in 1 package
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low IRM-values
Soft recovery behaviour
●
●
●
●
●
Antiparallel diode for high frequency
switching devices
Antisaturation diode
Snubber diode
Free wheeling diode in converters
and motor control circuits
Rectifiers in switch mode power
supplies (SMPS)
Inductive heating
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
Advantages
●
●
●
Avalanche voltage rated for reliable
operation
Soft reverse recovery for low
EMI/RFI
Low IRM reduces:
- Power dissipation within the diode
- Turn-on loss in the commutating
switch
Dimensions see CD "Databook 2000"
IXYS reserves the right to change limits, test conditions and dimensions.
© 1999 IXYS All rights reserved
940
Data according to IEC 60747 and per diode unless otherwise specified
1-1