TECHNICAL DATA
KKA8137
DUAL 5.1V REGULATOR WITH DISABLE AND RESET
The KKA8137 is a monolithic dual positive voltage regulator designed to
provide fixed precision output voltages of 5.1 V at currents up to 1 A. An
internal reset circuit generates a reset pulse when the output 1 decreases
below the regulated voltage value.
Output 2 can be disabled by TTL input.
Short circuit and thermal protections are included.
•
•
•
•
•
•
•
TO-220AB/7
Output currents up to 1 A
Fixed precision OUTPUT voltages 5.1 V ± 2%
OUTPUT 1 with RESET facility
OUTPUT 2 with DISABLE by TTL input
Short circuit protection at both outputs
Thermal protection
Low drop output voltage
HEPTAWAT
(Plastic Package)
ORDERING INFORMATION
KKA8137A
Plastic Package
KK8137A
chip
TJ = -0° to 130°C
PIN ASSIGNMENT
7
OUTPUT 1
6
5
OUTPUT 2
RESET
4
3
GROUND
DISABLE
2
DELAY CAP
1
INPUT
Tab connected to Pin 4
BLOCK DIAGRAM
INPUT
1
OUT 1
PREFERENCE
RESET
PROTECTION
DISABLE 3
DISABLE
OUT 2
7 OUT 1
5 RESET
CR
2
DELAY
CAP
6 OUT 2
4
1
KKA8137
MAXIMUM RATINGS*
Symbol
Parameter
Min
Max
Unit
VIN
DC Input Voltage Pin 1
20
V
VDIS
Disable Input Voltage Pin 3
20
V
VRST
Voltage at Pin 5
20
V
VIN = 7 V
1.6
A
VIN = 16 V
1.0
IO1,2 SC
Short Circuit Output Current
Tstg
Storage Temperature
-65
150
°C
TJ
Junction Temperature
0
150
°C
Min
Max
Unit
7.0
14
V
0
7.0
V
*
Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VIN
DC Input Voltage Pin 1
VDIS
Disable Input Voltage Pin 3
VRST
Voltage at Pin 5
10
V
IO1,2
Output Currents
1.0
A
130
°C
TJ
Junction Temperature
0
THERMAL DATA
Symbol
Rth (j-c)
Rth (j-a)
Parameter
Maximum Thermal Resistance Junction-case
Maximum Thermal Resistance Junction-ambient
Vlalue
Unit
6
o
C/W
60
o
C/W
2
KKA8137
ELECTRICAL CHRACTERISTICS (VIN = 7 V, TJ = 25°C, unless otherwise specified)
Symbol
VO1,2
Parameter
Guaranteed
Limit
Test Conditions
Output Voltage
Min
Max
VIN = 7 V, VDIS = 2.0 V,
IO1= -10 mA
5.0
5.2
7 V ≤ VIN ≤ 14 V,
-5 mA ≤ IO1 ≤ -750 mA, VDIS = 2.0 V
4.9
5.3
Unit
V
∆ VO1,2 LI
Line Regulation
7 V ≤ VIN ≤ 14 V, IO1,2 = -200 mA,
VDIS = 2.0 V
50
mV
∆ VO1,2 LO
Load Regulation
VIN = 7 V, -5 mA ≤ IO1,2 ≤ -0.6 mA,
VDIS = 2.0 V
100
mV
VIO1,2
Dropout Voltage
IO1,2 = -750 mA, VDIS = 2.0 V
1.4
V
IO1,2 = -1.0 mA, VDIS = 2.0 V
2.0
2.0
mA
-100
2.0
µA
K - 0.4
K – 0.1
V
20
75
мВ
IQ
Quiescent Current
VIN1 = 7 V, VIN2 = 10 V,
VDIS = 0.8 V, IO1= -10 mA
IDIS
Disable Bias Current
0 V ≤ VDIS ≤ 7 V,VIN = 7 V
Reset Threshold Voltage
K = VO1, VDIS = 2.0 V
VRTH
Reset Threshold Hysteresis
VDIS = 2.0 V
VRL
Saturation Volt. at Pin 5 in
Reset Condition
V5 = 5.0 V, VDIS = 2.0 V,
I5 = 5.0 mA
0.4
В
IRH
Leakage Current at Pin 5 in
Normal Condition
V5 = 10 V, VDIS = 2.0 V, VIN = 7 V
10
µA
tRD
Reset Pulse Delay at Pin 5
VDIS = 2.0 V, VIN = 5 V to 7 V
15
35
ns
VDISH
Disable Voltage High (out 2
active)
VIN = 7 V
2
VDISL
Disable Voltage Low (out 2
disabled)
VIN = 7 V
VO1RST
V
0.8
V
TYPICAL APPLICATION
DISABLE (03)
INPUT 1 (01)
OUTPUT 1 (07
KKA8137
OUTPUT 2 (06
C2
C1
C3
Ce
RESET(05)
GROUND (04)
C1 to C3 = 10 µF
tRD =
Сe •2.5V
10µA
3
KKA8137
2.8 0.07
TO-220 AB/7
9.9 0.11
4.5 1
+0.015
6.6 max
3.6
25.7 0.3
17.0
14.9
22.62
9.2 0.15
2
45
0,7 max
1.3
0.002
1
0.55
0.14
2.65 0.1
1.27
5.08
7 pins 0,7 0,1
6 127=7.62
4