LEM CV3-1000

VPN =
Voltage Transducer CV 3-1000
700 V
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
VPN
VP
VS
KN
RL
CL
VC
IC
Primary nominal r.m.s. voltage
Primary voltage, measuring range
Secondary Analog voltage @ VP max
Conversion ratio
Load resistance
Capacitive loading
Supply voltage (± 5 %)
Current consumption
700
0 .. ± 1000
10
1000 V / 10 V
≥1
≤5
± 15
32 + VS / R L
V
V
V
Features
• Closed loop (compensated) voltage
transducer
kΩ
nF
V
mA
• Insulated plastic case recognized
according to UL 94-V0
• Patent pending.
Advantages
Accuracy - Dynamic performance data
XG
Overall accuracy @ VP max
VO
Offset voltage @ VP = 0
TA = 25°C
- 40°C .. + 85°C
TA = 25°C
- 40°C .. + 85°C
tr
Response time 1) @ 90 % of VPN
dv/dt dv/dt accurately followed
f
Frequency bandwidth (- 1 dB) @ 50 % of VPN
Max
± 0.2
± 0.6
±5
± 13
0.3
800
DC .. 500
%
%
mV
mV
µs
V/µs
kHz
General data
TA
TS
P
R1
m
Note :
Ambient operating temperature
Ambient storage temperature
Total primary power loss
Primary resistance
Mass
Standards
1)
- 40 .. + 85
°C
- 45 .. + 90
°C
3.1
W
160
kΩ
560
g
EN 50155 : 1995
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low thermal drift
Low response time
High bandwidth
High immunity to external
interference
• Low disturbance in common mode.
Applications
•
•
•
•
•
Single or three phases inverter
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger.
Application Domain
• Traction.
With a dv/dt of 800 V/µs
050805/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Page 1/3
w w w .lem.com
Voltage transducer CV 3-1000
Isolation characteristics
Vd
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
6
kV
Ve
R.m.s. voltage for partial discharge extinction @ 10pC
2
kV
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (Group I )
Min
83.80
76.40
600
mm
mm
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer's
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
050805/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Page 2/3
w w w .lem.com
Dimensions CV 3-1000
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Connection
Rep.
Clearance
Creepage
A-B
76.40 mm
83.80 mm
Top view
Remarks
Mechanical characteristics
• General tolerance
• Transducer fastening
Recommended fastening torque
• Connection of primary
• Connection of secondary
• Recommended fastening torque
± 0.3 mm
3 holes ∅ 5.5 mm
3 M5 steel screws
3.8 Nm or 2.80 Lb. -Ft.
2 M5 threaded studs
4 M5 threaded studs
2.2 Nm or 1.62 Lb. -Ft.
• VS is positive when VP is applied on terminal +HT.
• CEM tested with a shielded secondary cable,
shield connected to 0 V at both ends, or disconnected.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
050805/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Page 3/3
w w w .lem.com