VPN = Voltage Transducer CV 3-1000 700 V For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit). Electrical data VPN VP VS KN RL CL VC IC Primary nominal r.m.s. voltage Primary voltage, measuring range Secondary Analog voltage @ VP max Conversion ratio Load resistance Capacitive loading Supply voltage (± 5 %) Current consumption 700 0 .. ± 1000 10 1000 V / 10 V ≥1 ≤5 ± 15 32 + VS / R L V V V Features • Closed loop (compensated) voltage transducer kΩ nF V mA • Insulated plastic case recognized according to UL 94-V0 • Patent pending. Advantages Accuracy - Dynamic performance data XG Overall accuracy @ VP max VO Offset voltage @ VP = 0 TA = 25°C - 40°C .. + 85°C TA = 25°C - 40°C .. + 85°C tr Response time 1) @ 90 % of VPN dv/dt dv/dt accurately followed f Frequency bandwidth (- 1 dB) @ 50 % of VPN Max ± 0.2 ± 0.6 ±5 ± 13 0.3 800 DC .. 500 % % mV mV µs V/µs kHz General data TA TS P R1 m Note : Ambient operating temperature Ambient storage temperature Total primary power loss Primary resistance Mass Standards 1) - 40 .. + 85 °C - 45 .. + 90 °C 3.1 W 160 kΩ 560 g EN 50155 : 1995 • • • • • • Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth High immunity to external interference • Low disturbance in common mode. Applications • • • • • Single or three phases inverter Propulsion and braking chopper Propulsion converter Auxiliary converter Battery charger. Application Domain • Traction. With a dv/dt of 800 V/µs 050805/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Components Page 1/3 w w w .lem.com Voltage transducer CV 3-1000 Isolation characteristics Vd R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 6 kV Ve R.m.s. voltage for partial discharge extinction @ 10pC 2 kV dCp dCl CTI Creepage distance Clearance distance Comparative Tracking Index (Group I ) Min 83.80 76.40 600 mm mm Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 050805/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Components Page 2/3 w w w .lem.com Dimensions CV 3-1000 (in mm. 1 mm = 0.0394 inch) Front view Left view Connection Rep. Clearance Creepage A-B 76.40 mm 83.80 mm Top view Remarks Mechanical characteristics • General tolerance • Transducer fastening Recommended fastening torque • Connection of primary • Connection of secondary • Recommended fastening torque ± 0.3 mm 3 holes ∅ 5.5 mm 3 M5 steel screws 3.8 Nm or 2.80 Lb. -Ft. 2 M5 threaded studs 4 M5 threaded studs 2.2 Nm or 1.62 Lb. -Ft. • VS is positive when VP is applied on terminal +HT. • CEM tested with a shielded secondary cable, shield connected to 0 V at both ends, or disconnected. • This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. 050805/8 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Components Page 3/3 w w w .lem.com