NTE RX2600-6

ECG Label and Adhesive Remover
MATERIAL SAFETY DATA SHEET
Finished Product
Date-Issued:
MSDS Ref. No:
Date-Revised:
Revision No:
01/20/2003
RX2600-6
01/20/2003
New MSDS
ECG Label and Adhesive Remover
1. PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NAME: ECG Label and Adhesive Remover
PRODUCT DESCRIPTION: Label/Adhesive Remover
PRODUCT CODE: RX2600-6
MANUFACTURER
NTE Electronics, Inc.
44 Farrand St.
Bloomfield, NJ 07003
24 HR. EMERGENCY TELEPHONE NUMBERS
CHEMTREC (U.S.): (800) 424-9300
CANUTEC: (613) 996-6666
Emergency Phone: 1-888-748-1777 8:00 am - 5:00 pm CST
Phone: 973-748-5089
2. COMPOSITION / INFORMATION ON INGREDIENTS
Chemical Name
Wt.%
CAS#
d-Limonene
30 - 50
5989-27-5
Mixed Aliphatic Hydrocarbons
70 - 85
64742-489
1-4
124-38-9
Carbon dioxide
EEC LABEL SYMBOL AND CLASSIFICATION
EEC Irritant - "Xi"
3. HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
PHYSICAL APPEARANCE: Clear to amber, sticky resin.
EINECS#
ECG Label and Adhesive Remover
POTENTIAL HEALTH EFFECTS
EYES: Liquid contact can cause irritation, which may be severe.
SKIN: Prolonged or repeated contact may cause skin irritation.
INGESTION: Harmful if swallowed.
INHALATION: Prolonged or excessive inhalation may cause respiratory tract irritation.
SIGNS AND SYMPTOMS OF OVEREXPOSURE
EYES: Contact may cause eye irritation.
SKIN: May cause slight irritation.
INGESTION: Not a likely route of exposure.
4. FIRST AID MEASURES
EYES: Immediately flush eyes with plenty of water. Get medical attention, if irritation persists.
SKIN: Wash with soap and water. Get medical attention if irritation develops or persists.
INGESTION: Ingestion is unlikely because of the physical properties and is not expected to be hazardous. Do not
induce vomiting unless instructed to do so by a physician.
INHALATION: Remove to fresh air.
5. FIRE FIGHTING MEASURES
FLAMMABLE LIMITS: 0.7% to 3.1%
GENERAL HAZARD: Combustible Liquid. Can form explosive mixtures at temperatures at or above the flash
point.
HAZARDOUS COMBUSTION PRODUCTS: Smoke, fumes and oxides of carbon.
6. ACCIDENTAL RELEASE MEASURES
SMALL SPILL: Avoid runoff into storm sewers and ditches which lead to waterways.
LARGE SPILL: -Implement cleanup procedures.
-If in public area, keep public away and advise authorities.
-Recover by pumping (use an explosion proof or hand pump) or with a suitable absorbent.
ENVIRONMENTAL PRECAUTIONS
WATER SPILL: This material is a water pollutant and should be prevented from contaminating soil or from
entering sewage and drainage systems and bodies of water.
RELEASE NOTES: Spills and releases may have to be reported to Federal and/or local authorities.
file:///N|/MSDS/8590wvwy.htm (2 of 6)1/13/2004 12:00:25 PM
ECG Label and Adhesive Remover
SPECIAL PROTECTIVE EQUIPMENT: Only personnel equipped with proper respiratory and skin/eye
protection should be permitted in area. See Section 8 for details.
7. HANDLING AND STORAGE
GENERAL PROCEDURES: Keep container closed when not in use.
HANDLING: Avoid prolonged or repeated contact with skin.
STORAGE: Keep away from sources of ignition.
STORAGE TEMPERATURE: (120°F) maximum
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
EXPOSURE GUIDELINES:
OSHA HAZARDOUS COMPONENTS (29 CFR 1910.1200)
EXPOSURE LIMITS
OSHA PEL
ACGIH TLV
ppm mg/m3 ppm mg/m3
d-Limonene
TWA
Mixed Aliphatic Hydrocarbons
OSHA TABLE COMMENTS:
1. NL = Not Listed
TWA 1900
Supplier OEL
ppm
mg/m
3
[1]
PERSONAL PROTECTIVE EQUIPMENT
EYES AND FACE: For normal conditions, wear safety glasses. Where there is reasonable probability of liquid
contact, wear splash-proof goggles.
SKIN: The glove(s) listed below may provide protection against permeation. Gloves of other chemically
resistant materials may not provide adequate protection.
Buna
Butyl
Natural Latex
Neoprene
Solvex
Viton
9. PHYSICAL AND CHEMICAL PROPERTIES
PHYSICAL STATE: Liquid
ODOR: Strong, fruity odor.
COLOR: Clear to Light yellow
file:///N|/MSDS/8590wvwy.htm (3 of 6)1/13/2004 12:00:25 PM
ECG Label and Adhesive Remover
pH: Not Applicable
PERCENT VOLATILE: 30
BOILING POINT: (325°F) to (332°F)
SPECIFIC GRAVITY: 0.7630 to 0.7930 @ 25°C
(VOC): 750 to 800 g/L (non-exempt VOC)
10. STABILITY AND REACTIVITY
STABLE: YES
HAZARDOUS POLYMERIZATION: NO
STABILITY: Stable under normal conditions.
HAZARDOUS DECOMPOSITION PRODUCTS: Carbon Dioxide and carbon Monoxide may form when heated
to decomposition.
11. TOXICOLOGICAL INFORMATION
EYE EFFECTS: May be mildly irritating to eyes.
12. ECOLOGICAL INFORMATION
ENVIRONMENTAL DATA: There is limited information available on the environmental fate and effects of this
material. The primary environmental concern for release is the impact on aquatic and terrestrial species. Due care
should be taken to avoid the accidental release of this material into the environment.
13. DISPOSAL CONSIDERATIONS
DISPOSAL METHOD: Federal, State, and Local laws governing disposal of materials can differ. Ensure
compliance with proper authorities before disposal.
14. TRANSPORT INFORMATION
DOT (DEPARTMENT OF TRANSPORTATION)
PROPER SHIPPING NAME: CONSUMER COMMODITY ORM-D
TECHNICAL NAME: Terpene Hydrocarbons N.O.S.
PRIMARY HAZARD CLASS/DIVISION: No classification
AIR (ICAO/IATA)
PROPER SHIPPING NAME: CONSUMER COMMODITY ID8000
PRIMARY HAZARD CLASS/DIVISION: 9
UN/NA NUMBER: ID8000
PACKING GROUP: NA
file:///N|/MSDS/8590wvwy.htm (4 of 6)1/13/2004 12:00:25 PM
ECG Label and Adhesive Remover
VESSEL (IMO/IMDG)
PROPER SHIPPING NAME: AEROSOLS IN LIMITED QUANTITIES OF CLASS 2
PRIMARY HAZARD CLASS/DIVISION: 2.2
UN/NA NUMBER: 1950
PACKING GROUP: NA
15. REGULATORY INFORMATION
UNITED STATES
TSCA (TOXIC SUBSTANCE CONTROL ACT)
TSCA STATUS: All components of this product are either listed or exempt from listing in the TSCA
inventory.
CANADA
DOMESTIC SUBSTANCE LIST (INVENTORY): All components of this product are listed on the Canadian
DSL.
EUROPEAN COMMUNITY
EEC LABEL SYMBOL AND CLASSIFICATION
EEC Irritant - "Xi"
16. OTHER INFORMATION
APPROVED BY: Pierce A. Pillon
TITLE: Chemist
REVISION SUMMARY New MSDS
NFPA CODES
2
1
0
DATA SOURCES: Code of Federal Regulations (CFR)
The Sigma-Aldrich Library of Regulatory and Safety Data
OSHA Hazard Communication Standard (29CFR1910.1200)
Various Federal, State and Local Regulations
file:///N|/MSDS/8590wvwy.htm (5 of 6)1/13/2004 12:00:25 PM
ECG Label and Adhesive Remover
MANUFACTURER DISCLAIMER: To the best of our knowledge, the information contained herein is accurate.
However, neither Stratus, or any of its subsdiaries assumes any liability whatsoever for the accuracy or
completeness of the information contained herein. Final determination of suitability of any material is the sole
responsibility of the user. All materials my present unknown hazards and should by used wth caution. Although
certain hazards are described herein, we cannot guarantee that these are the only hazards which exist.
file:///N|/MSDS/8590wvwy.htm (6 of 6)1/13/2004 12:00:25 PM