H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION(PFC) AC-DC N+1 REDUNDANCY AND LOAD SHARING INTERNAL 1U RACK SWITCHING POWER SUPPLIES 950 WATTS DUAL OUTPUT HVP950 SERIES FEATURES: 1U HEIGHT RACK POWER SUPPLY BUILT-IN ACTIVE PFC FUNCTION INTERNAL OR-ING DIODES FOR N+1 REDUNDANCY HOT-SWAPPABLE HIGH EFFICIENCY & DENSITY PMBus COMMUNICATION CE MARKING COMPLIANT SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typ. 90-264Vac. Power Factor: Meet Harmonic Correction IEC 61000-3-2. Power Factor typ. 0.98. Input Connector: IEC320-C14 3prong. Input Frequency: 47-63Hz. Inrush Current: 10.4A(rms) at 230Vac; 29A (peak) at 230Vac. Input Current: 9A at 115Vac / 4.5A at 230Vac. Dielectric Withstand: Meet IEC 60950-1 regulation. EMI: Meet EN 55022 FCC Class B. Hold-up Time: Typ. 10mS at 115Vac. Remote ON/OFF: Available. Power Fail Signal: Available. Over Temperature Protection (OTP): Installed NTC and thermostat. Leakage Current: Typ. 0.8mA at 230Vac. No-Load Power: Typ. 9 Watt at 115Vac & 7W at 230Vac. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Power: Total continuous 950W. Output Connector: ALLTOP C24501-128H1-Y. Line Regulation: VO1/2 typ. ±1%. Load Regulation: VO1/2 typ. ±3%. Total Regulation: VO1/2 typ. ±3%. Noise & Ripple: Typ. 1% peak-peak. OVP: Built-in at all outputs. Adjustability: Available for all outputs. Hot-Swap: Available. N+1 Redundancy: Installed with internal OR-ing diodes at all outputs and third-wire current sharing method for N+1 redundancy operation. Current Sharing: Available for all outputs. DC OK Signal: Available for all outputs. Over Current Protection (OCP): Built-in. Overload Protection (OLP): Fully protected against output overload or short circuit. OLP set at about 120-130% rating output wattage. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typ. 91% at 230Vac. Switching Frequency: 85-100KHz. Circuit Topology: Half-bridge circuit ZVS circuit. Transient Response: Peak transient less than 220mV and recover within 3 mS at 25% load-change. Safety Standard: IEC 60950-1 Class I. Construction: 1U Rack Format. Operating Temperature: -10 °C to +70 °C(refer to derating chart). Storage Temperature: -40°C to +85 °C. Cooling: Built-in one internal DC ball bearing fan with smart fan speed control. Power Density: Typ. 15 Watts/ cubic inch. PMBus: Built-in. NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications. (2)Due to requests in market and advances in technology, specifications subject to change without notification. Hitron Electronics Corporation. B4-11, P.O. Box 26-110 Kaohsiung Export Processing Zone Kaohsiung 806 Taiwan TEL: 886-7-8210410/FAX: 886-7-8419917, 886-7-8210511/E-mail: [email protected]/ Web-site: www.hitron-e.com 1 OTPUT VOLTAGE / CURRENT RATINGS CHART DUAL OUTPUT MAIN +VO1 @★≡⊙ MODEL NO. HVP950-D560I AUX +VO2 @★≡⊙ Min. Typ. Volt. Max. Peak Min. Typ. Volt. Max. Peak 0A 13.4A +56V 13.4A 13.4A 0A 16.6A +12V 16.6A 16.6A Symbol: "★" OVP built-in. "@" Adjustable. "≡" Load Sharing. "⊙" Installed with Or-ing diode. Remark: Maximum Output Power <=950 Watt WEIGHT: 1.6kgs (3.5lb) MECHANICAL DIMENSIONS: MM [INCHES] DERATING CHART INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT CNT1 CNT2 L N G P1 P2 LINE NEUTRAL GND VO2 COM D1 Alert C1 PS_PRNT B1 12V_CS A1 SCL D2 D3 D4 D5 A2 DGND 5VSB N/A C2 C3 C4 C5 A1 PS_EN_IN DCOK_12V_L N/A B2 B3 B4 B5 A0 PS_EN_OUT DCOK_56V_L N/A A2 A3 A4 A5 SDA AC_FAIL FAN_FAL N/A D6 56V_CS C6 N/A B6 N/A A6 N/A Hitron Electronics Corporation. B4-11, P.O. Box 26-110 Kaohsiung Export Processing Zone Kaohsiung 806 Taiwan TEL: 886-7-8210410/FAX: 886-7-8419917, 886-7-8210511/E-mail: [email protected]/ Web-site: www.hitron-e.com P3 P4 VO1 RTN VO1 2