hitron-e.com

H HiTRON
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC
6U PENTAD OUTPUT 1000 WATTS VPX SWITCHING
POWER SUPPLIES HAV1000 SERIES
FEATURES:






VITA 62 COMPLIANT 6U VPX POWER
SUPPLY
WIDE OPERATING TEMPERATURE RANGE
OF -40°C TO +85 °C
INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
ACTIVE CURRENT SHARING
EMI MEET EN 55022 / CLASS A
PMBus INTERFACE FOR STATUS &
CONTROL
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac.
Power Factor: Meet Harmonic Correction IEC 61000-3-2.
Power Factor typ. 0.98-0.99.
Input Connector: Tyco 6450843-6.
Input Frequency: 47-63Hz.
Inrush Current: 10A(rms) at 230Vac;
37.2A (peak) at 230Vac.
Input Current: 7.3A at 115Vac / 5.2A at 230Vac.
Dielectric Withstand: Meet IEC 60950-1 regulation.
EMI: Meet EN 55022 FCC Class A.
Hold-up Time: Typ. 6.2mS at 115Vac/2.3mS at 230Vac.
Remote ON/OFF: Available.
Power Fail Signal: Available.
Over Temperature Protection (OTP): Installed NTC and
thermostat.
Leakage Current: Typ. 1.1mA at 230Vac.
No-Load Power: Typ. 11.8Watt at 115Vac & 230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Power: 700W at 90-180Vac/1000W at 180-264Vac.
Output Connector: Tyco 6450849-6.
Line Regulation: Typ. 1%.
Load Regulation: VO1/2/3 typ. ±2% ; VO4/5 typ. ±5%.
Total Regulation: VO1/2/3 typ. ±3%; VO4/5 typ. ±5%
Noise & Ripple: Typ. 1.5% pk-pk.
OVP: Built-in at all outputs.
Adjustability: Available at VO1/2/3.
N+1 Redundancy: Installed with internal OR-ing diodes at all
outputs and third-wire current sharing
method for N+1 redundancy operation.
Current Sharing: Active current sharing at VO1,2 & 3.
DC OK Signal: Available for all outputs.
Power OK Signal: Available for all outputs.
Over Current Protection (OCP): Installed at each rail.
Overload Protection (OLP): Fully protected against output
overload or short circuit. Typ. 110-150% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 86% at 230Vac.
Switching Frequency: 67-100K Hz.
Circuit Topology: ZVS Half-Bridge circuit.
Transient Response: Peak transient less than 1200mV and
recovers within 2ms for 25% load-change.
Safety Standard: IEC 60950-1 Class I.
PMBus: Built-in.
Operating Temperature: -40 °C to +85 °C (see note 3/derating chart) ,
derate linearly from 100% power at +50 °C to
55% power at +85 °C.
Storage Temperature: -45 to +90 °C.
Cooling: At least 800LFM moving air is required to achieve
full rating power in a confined area.
Power Density: 5.8-8.3 Watts/ Cubic Inch.
NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2)Due to requests in market and advances in technology, specifications subject to change without notification.
(3)A warm-up time 3 minutes is required to maintain outputs within specific spec. after cold start at temperature from -40 °C to +0°C.
(4)Tantalum capacitors connected to system is suggested for bettering Ripple & Noise against operating temperature from -40°C to +0°C.
(5)125 degree C OS-CON Long-life Solid capacitors are installed in secondary circuits.
-1-
Rev.B Edited on May 1, 2015 OUTPUT VOLTAGE / CURRENT RATINGS CHART
QUAD OUTPUT
MODEL NO.
O/P Volt.
VO1
VO2
VO3
VO4
VO5
HAV1000-P120EDII
Min.
0A(1.0A)
0A(1.0A)
0A(1.0A)
0A(0.1A)
0A(0.1A)
Volt.
12V
5V
3.3V
12V
-12V
Typ.
55A
25A
20A
1A
1A
Max.
60A
30A
25A
2A
2A
Peak.
60A
30A
25A
2A
2A
Remark: 1. Max. Output power<=700W at 90-180Vac, 1000Watt at 180-264Vac.
2. For parallel application, a certain minimum current of outputs is required.
MECHANICAL DIMENSIONS: MM [INCHES]
DERATING CHART
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
P0
P1
P0-P7 P0-P4 P0-P1
L
N
G
P1
COM
P2
VO3
3.3V
Aux.
D1
D2
PS_RNT
EN
P3
P4
P5
P6
D3
D4
D5
D6
N/A
A0
N/A
SYS
RST
C1
C2
C3
C4
C5
C6
V3
+S
INH
N/A
A1
N/A
VO5
-12V
B1
B2
B3
B4
B5
B6
V3
-S
FAL
VO4
+12V
A2
SCL
COM COM
VO2
P03
+5V
VO2
P03
+5V
P8
D7
D8
D9
C8
V2
-S
B8
C9
V2
+S
B9
N/A
N/A
N/A
N/A
A7
V1
CS
A8
V1
-S
A9
V1
+S
A2
A3
A4
A5
A6
V3
CS
N/A
N/A
Alert
SDA
N/A
P9
P10
COM DEG. I/P_ok
C7
V2
CS
B7
A1
-2-
P7
COM
COM
VO1 VO1
P02 P01
+12V +12V
Rev.B Edited on May 1, 2015