HOLTEK HT46RU22_08

HT46RU22
A/D Type 8-Bit MCU
Technical Document
· Tools Information
· FAQs
· Application Note
- HA0004E HT48 & HT46 MCU UART Software Implementation Method
- HA0005E Controlling the I^2C bus with the HT48 & HT46 MCU Series
- HA0013E HT48 & HT46 LCM Interface Design
- HA0047E An PWM application example using the HT46 series of MCUs
- HA0075E MCU Reset and Oscillator Circuits Application Note
Features
· Operating voltage:
· Up to 0.5ms instruction cycle with 8MHz system clock
fSYS=4MHz: 2.2V~5.5V
fSYS=8MHz: 3.3V~5.5V
at VDD=5V
· 6-level subroutine nesting
· 19 bidirectional I/O lines (max.)
· 8 channels 9-bit resolution A/D converter
· 1 interrupt input shared with an I/O line
· 1-channel 8-bit PWM output shared with one I/O line
· 8-bit programmable timer/event counter with
· Universal Asynchronous Receiver Transmitter
overflow interrupt and 7-stage prescaler
(UART)
· On-chip crystal and RC oscillator
· Bit manipulation instruction
· Watchdog Timer
· 14-bit table read instruction
· 2048´14 program memory
· 63 powerful instructions
· 64´8 data memory RAM
· All instructions in one or two machine cycles
· Supports PFD for sound generation
· Low voltage reset function
· HALT function and wake-up feature reduce power
· I2C Bus (slave mode)
consumption
· 24-pin SKDIP/SOP/SSOP package
General Description
Width Modulation function, UART function, I2C interface, HALT and wake-up functions, enhance the versatility of these devices to suit a wide range of A/D
application possibilities such as sensor signal processing, motor driving, industrial control, consumer products, subsystem controllers, etc.
The HT46RU22 are 8-bit, high performance, RISC architecture microcontroller devices specifically designed
for A/D applications that interface directly to analog signals, such as those from sensors.
The advantages of low power consumption, I/O flexibility, programmable frequency divider, timer functions,
oscillator options, multi-channel A/D Converter, Pulse
I2C is a trademark of Philips Semiconductors
Rev. 1.21
1
December 29, 2008
HT46RU22
Block Diagram
P A 5 /IN T
In te rru p t
C ir c u it
S T A C K
P ro g ra m
R O M
P ro g ra m
C o u n te r
M
T M R C
T M R
IN T C
P A 3 /P F D
U
P r e s c a le r
M
M P
U
W D T
P r e s c a le r
D A T A
M e m o ry
X
P A 4
U
X
P o rt D
O S C
P D 0 /P W M
M U X
In s tr u c tio n
D e c o d e r
8 -C h a n n e l
A /D C o n v e rte r
S T A T U S
A L U
P B C
S h ifte r
T im in g
G e n e ra to r
P A 3 , P A 5
S
S
C 1
A C C
P o rt B
P B
P A C
O S
R E
V D
V S
W D T
/4
R C
P D
O S C 2
Y S
M
P W M
P D C
Y S
P A 4 /T M R
X
fS
In s tr u c tio n
R e g is te r
fS
P o rt A
P A
L V R
I2 C B u s
S la v e M o d e
D
P C
P C C
P o rt C
P B 0 /A N 0 ~
P B 7 /A N 7
P A
P A
P A
P A
P A
P A
0 ~ P
3 /P
4 /T
5 /IN
6 /S
7 /S
A 2
F D
M R
T
D A
C L
P C 0 /T X , P C 1 /R X
Pin Assignment
P B 5 /A N 5
1
2 4
P B 6 /A N 6
P B 4 /A N 4
2
2 3
P B 7 /A N 7
P A 3 /P F D
3
2 2
P A 4 /T M R
P A 2
4
2 1
P A 5 /IN T
P A 1
5
2 0
P A 6 /S D A
P A 0
6
1 9
P A 7 /S C L
P B 3 /A N 3
7
1 8
O S C 2
P B 2 /A N 2
8
1 7
O S C 1
P B 1 /A N 1
9
1 6
V D D
P B 0 /A N 0
1 0
1 5
R E S
V S S
1 1
1 4
P D 0 /P W M
P C 0 /T X
1 2
1 3
P C 1 /R X
H T 4 6 R U 2 2
2 4 S K D IP -A /S O P -A /S S O P -A
Rev. 1.21
2
December 29, 2008
HT46RU22
Pad Description
Pad Name
I/O
Options
Description
I/O
Pull-high
Wake-up
PA3 or PFD
I/O or Serial Bus
Bidirectional 8-bit input/output port. Each bit can be configured as wake-up
input by options. Software instructions determine the CMOS output or
Schmitt trigger input with or without pull-high resistor (determined by pull-high
options: bit option). The PFD, TMR and INT are pin-shared with PA3, PA4
and PA5, respectively. Once the I2C Bus function is used, the internal registers related to PA6 and PA7 can not be used.
Pull-high
Bidirectional 8-bit input/output port. Software instructions determine the
CMOS output, Schmitt trigger input with or without pull-high resistor (determined by pull-high option: port option) or A/D input.
Once a PB line is selected as an A/D input (by using software control), the
I/O function and pull-high resistor are disabled automatically.
I/O
Pull-high
Bidirectional 2-bit input/output port. Software instructions determine the
CMOS output, Schmitt trigger input with or without pull-high resistor (determine by pull-high option: bit option).
TX and RX are pin-shared with PC0 and PC1, once the UART Bus function
is used, the internal registers related to PC0 and PC1 can not be used. Software instructions determine the UART function to be used.
PD0/PWM
I/O
Pull-high
I/O or PWM
Bidirectional 1-bit input/output port. Software instructions determine the
CMOS output, Schmitt trigger input with or without a pull-high resistor (determined by pull-high option: port option). The PWM output function is
pin-shared with PD0 (dependent on PWM options).
OSC1
OSC2
I
O
Crystal or RC
OSC1, OSC2 are connected to an RC network or a Crystal (determined by
options) for the internal system clock. In the case of RC operation, OSC2 is
the output terminal for 1/4 system clock.
RES
I
¾
Schmitt trigger reset input. Active low.
VSS
¾
¾
Negative power supply, ground.
VDD
¾
¾
Positive power supply
I
¾
TEST mode input pin
It disconnects in normal operation
PA0~PA2
PA3/PFD
PA4/TMR
PA5/INT
PA6/SDA
PA7/SCL
PB0/AN0
PB1/AN1
PB2/AN2
PB3/AN3
PB4/AN4
PB5/AN5
PB6/AN6
PB7/AN7
PC0/TX
PC1/RX
TEST1
TEST2
TEST3
I/O
Absolute Maximum Ratings
Supply Voltage ...........................VSS-0.3V to VSS+6.0V
Storage Temperature ............................-50°C to 125°C
Input Voltage..............................VSS-0.3V to VDD+0.3V
IOL Total ..............................................................150mA
Total Power Dissipation .....................................500mW
Operating Temperature...........................-40°C to 85°C
IOH Total............................................................-100mA
Note: These are stress ratings only. Stresses exceeding the range specified under ²Absolute Maximum Ratings² may
cause substantial damage to the device. Functional operation of this device at other conditions beyond those
listed in the specification is not implied and prolonged exposure to extreme conditions may affect device
reliability.
Rev. 1.21
3
December 29, 2008
HT46RU22
D.C. Characteristics
Ta=25°C
Test Conditions
Symbol
Parameter
VDD
IDD1
IDD2
IDD3
Min.
Typ.
Max.
Unit
Conditions
VDD
¾
fSYS=4MHz
2.2
¾
5.5
V
¾
fSYS=8MHz
3.3
¾
5.5
V
Operating Current
(Crystal OSC)
3V
No load, fSYS=4MHz
ADC Off, UART Off
¾
0.6
1.5
mA
¾
2
4
mA
Operating Current
(RC OSC)
3V
¾
0.8
1.5
mA
¾
2.5
4
mA
Operating Current
(Crystal OSC, RC OSC)
3V
¾
1
2
mA
¾
3
6
mA
Operating Voltage
5V
5V
5V
No load, fSYS=4MHz
ADC Off, UART Off
No load, fSYS=4MHz,
ADC Off, UART On
IDD4
Operating Current
(Crystal OSC, RC OSC)
5V
No load, fSYS=8MHz,
ADC Off, UART Off
¾
4
8
mA
IDD5
Operating Current
(Crystal OSC, RC OSC)
5V
No load, fSYS=8MHz,
ADC Off, UART On
¾
5
10
mA
ISTB1
Standby Current
(WDT Enabled)
3V
¾
¾
5
mA
¾
¾
10
mA
Standby Current
(WDT Disabled)
3V
¾
¾
1
mA
¾
¾
2
mA
VIL1
Input Low Voltage for I/O Ports,
TMR and INT
¾
¾
0
¾
0.3VDD
V
VIH1
Input High Voltage for I/O Ports,
TMR and INT
¾
¾
0.7VDD
¾
VDD
V
VIL2
Input Low Voltage (RES)
¾
¾
0
¾
0.4VDD
V
VIH2
Input High Voltage (RES)
¾
¾
0.9VDD
¾
VDD
V
VLVR
Low Voltage Reset
¾
¾
2.7
3
3.3
V
IOL
I/O Port Sink Current
ISTB2
IOH
RPH
No load, system HALT
5V
No load, system HALT
5V
3V
VOL=0.1VDD
4
8
¾
mA
5V
VOL=0.1VDD
10
20
¾
mA
3V
VOH=0.9VDD
-2
-4
¾
mA
5V
VOH=0.9VDD
-5
-10
¾
mA
3V
¾
20
60
100
kW
5V
¾
10
30
50
kW
I/O Port Source Current
Pull-high Resistance
VAD
A/D Input Voltage
¾
¾
0
¾
VDD
V
EAD
A/D Conversion Error
¾
¾
¾
±0.5
±1
LSB
IADC
Additional Power Consumption
if A/D Converter is Used
3V
¾
0.5
1
mA
¾
1.5
3
mA
Rev. 1.21
¾
5V
4
December 29, 2008
HT46RU22
A.C. Characteristics
Ta=25°C
Test Conditions
Symbol
Parameter
fSYS
fTIMER
tWDTOSC
System Clock
(Crystal OSC, RC OSC)
Timer I/P Frequency
(TMR)
Min.
Typ.
Max.
Unit
Conditions
VDD
¾
2.2V~5.5V
400
¾
4000
kHz
¾
3.3V~5.5V
400
¾
8000
kHz
¾
2.2V~5.5V
0
¾
4000
kHz
¾
3.3V~5.5V
0
¾
8000
kHz
3V
¾
45
90
180
ms
5V
¾
32
65
130
ms
¾
1
¾
¾
ms
¾
1024
¾
*tSYS
Watchdog Oscillator Period
tRES
External Reset Low Pulse Width
¾
tSST
System Start-up Timer Period
¾
tLVR
Low Voltage Width to Reset
¾
¾
0.25
1
2
ms
tINT
Interrupt Pulse Width
¾
¾
1
¾
¾
ms
tAD
A/D Clock Period
¾
¾
1
¾
¾
ms
tADC
A/D Conversion Time
¾
¾
¾
76
¾
tAD
tADCS
A/D Sampling Time
¾
¾
¾
32
¾
tAD
tIIC
I2C Bus Clock Period
¾
Connect to external
pull-high resistor 2kW
64
¾
¾
*tSYS
Wake-up from HALT
Note: *tSYS=1/fSYS
Rev. 1.21
5
December 29, 2008
HT46RU22
Functional Description
Execution Flow
cremented by 1. The program counter then points to the
memory word containing the next instruction code.
The system clock for the microcontroller is derived from
either a crystal or an RC oscillator. The system clock is
internally divided into four non-overlapping clocks. One
instruction cycle consists of four system clock cycles.
When executing a jump instruction, conditional skip execution, loading PCL register, subroutine call, initial reset, internal interrupt, external interrupt or return from
subroutine, the PC manipulates the program transfer by
loading the address corresponding to each instruction.
Instruction fetching and execution are pipelined in such
a way that a fetch takes an instruction cycle while decoding and execution takes the next instruction cycle.
However, the pipelining scheme causes each instruction to effectively execute in a cycle. If an instruction
changes the program counter, two cycles are required to
complete the instruction.
The conditional skip is activated by instructions. Once
the condition is met, the next instruction, fetched during
the current instruction execution, is discarded and a
dummy cycle replaces it to get the proper instruction.
Otherwise proceed with the next instruction.
The lower byte of the program counter (PCL) is a readable and writeable register (06H). Moving data into the
PCL performs a short jump. The destination will be
within 256 locations.
Program Counter - PC
The program counter (PC) controls the sequence in
which the instructions stored in program ROM are executed and its contents specify full range of program
memory.
When a control transfer takes place, an additional
dummy cycle is required.
After accessing a program memory word to fetch an instruction code, the contents of the program counter are in-
S y s te m
O S C 2 (R C
C lo c k
T 1
T 2
T 3
T 4
T 1
T 2
T 3
T 4
T 1
T 2
T 3
T 4
o n ly )
P C
P C
P C + 1
F e tc h IN S T (P C )
E x e c u te IN S T (P C -1 )
P C + 2
F e tc h IN S T (P C + 1 )
E x e c u te IN S T (P C )
F e tc h IN S T (P C + 2 )
E x e c u te IN S T (P C + 1 )
Execution Flow
Mode
Program Counter
*10
*9
*8
*7
*6
*5
*4
*3
*2
*1
*0
Initial Reset
0
0
0
0
0
0
0
0
0
0
0
External Interrupt
0
0
0
0
0
0
0
0
1
0
0
Timer/Event Counter Overflow
0
0
0
0
0
0
0
1
0
0
0
A/D Converter Interrupt
0
0
0
0
0
0
0
1
1
0
0
I2C Bus Interrupt
0
0
0
0
0
0
1
0
0
0
0
UART Interrupt
0
0
0
0
0
0
1
0
1
0
0
@3
@2
@1
@0
Skip
Program Counter + 2
Loading PCL
*10
*9
*8
@7
@6
@5
@4
Jump, Call Branch
#10
#9
#8
#7
#6
#5
#4
#3
#2
#1
#0
Return from Subroutine
S10
S9
S8
S7
S6
S5
S4
S3
S2
S1
S0
Program Counter
Note:
*10~*0: Program counter bits
#10~#0: Instruction code bits
Rev. 1.21
S10~S0: Stack register bits
@7~@0: PCL bits
6
December 29, 2008
HT46RU22
Program Memory - ROM
current page, 1 page=256 words) and ²TABRDL [m]²
(the last page) transfer the contents of the lower-order
byte to the specified data memory, and the higher-order byte to TBLH (08H). Only the destination of the
lower-order byte in the table is well-defined, the other
bits of the table word are transferred to the lower portion of TBLH, and the remaining 2 bit is read as ²0².
The Table Higher-order byte register (TBLH) is read
only. The table pointer (TBLP) is a read/write register
(07H), which indicates the table location. Before accessing the table, the location must be placed in
TBLP. The TBLH is read only and cannot be restored.
If the main routine and the ISR (Interrupt Service Routine) both employ the table read instruction, the contents of the TBLH in the main routine are likely to be
changed by the table read instruction used in the ISR.
Errors can occur. In other words, using the table read
instruction in the main routine and the ISR simultaneously should be avoided. However, if the table read
instruction has to be applied in both the main routine
and the ISR, the interrupt is supposed to be disabled
prior to the table read instruction. It will not be enabled
until the TBLH has been backed up. All table related
instructions require two cycles to complete the operation. These areas may function as normal program
memory depending upon the requirements.
The program memory is used to store the program instructions which are to be executed. It also contains
data, table, and interrupt entries, and is organized into
2048´14 bits, addressed by the program counter and table pointer.
Certain locations in the program memory are reserved
for special usage:
· Location 000H
This area is reserved for program initialization. After
chip reset, the program always begins execution at location 000H.
· Location 004H
This area is reserved for the external interrupt service
program. If the INT input pin is activated, the interrupt
is enabled and the stack is not full, the program begins
execution at location 004H.
· Location 008H
This area is reserved for the timer/event counter interrupt service program. If a timer interrupt results from a
timer/event counter overflow, and if the interrupt is enabled and the stack is not full, the program begins execution at location 008H.
· Location 00CH
0 0 0 H
This area is reserved for the A/D converter interrupt
service program. If an A/D converter interrupt results
from an end of A/D conversion, and if the interrupt is
enabled and the stack is not full, the program begins
execution at location 00CH.
D e v ic e In itia liz a tio n P r o g r a m
0 0 4 H
0 0 8 H
0 0 C H
E x te r n a l In te r r u p t S u b r o u tin e
T im e r /E v e n t C o u n te r In te r r u p t S u b r o u tin e
A /D
0 1 0 H
· Location 010H
This area is reserved for the I2C Bus interrupt service
program. If the I2C Bus interrupt resulting from a slave
address is match or completed 1 byte of data transfer,
and if the interrupt is enable and the stack is not full,
the program begins execution at location 010H.
0 1 4 H
C o n v e r te r In te r r u p t S u b r o u tin e
I C B u s In te r r u p t S u b r o u tin e
2
P ro g ra m
M e m o ry
U A R T B u s In te r r u p t S u b r o u tin e
n 0 0 H
L o o k - u p T a b le ( 2 5 6 w o r d s )
n F F H
· Location 014H
This area is reserved for the UART interrupt service
program. If the UART interrupt resulting from transmission/reception is completed, and if the interrupt is
enable and the stack is not full, the program begins
execution at location 014H.
7 0 0 H
L o o k - u p T a b le ( 2 5 6 w o r d s )
7 F F H
1 4 b its
N o te : n ra n g e s fro m
0 to 7
Program Memory
· Table location
Any location in the ROM space can be used as
look-up tables. The instructions ²TABRDC [m]² (the
Table Location
Instruction
*10
*9
*8
*7
*6
*5
*4
*3
*2
*1
*0
TABRDC [m]
P10
P9
P8
@7
@6
@5
@4
@3
@2
@1
@0
TABRDL [m]
1
1
1
@7
@6
@5
@4
@3
@2
@1
@0
Table Location
Note:
*10~*0: Table location bits
@7~@0: Table pointer bits
Rev. 1.21
P10~P8: Current program counter bits
7
December 29, 2008
HT46RU22
Stack Register - STACK
Accumulator
This is a special part of the memory which is used to
save the contents of the program counter (PC) only. The
stack is organized into 6 levels and is neither part of the
data nor part of the program space, and is neither readable nor writeable. The activated level is indexed by the
stack pointer (SP) and is neither readable nor writeable.
At a subroutine call or interrupt acknowledgment, the
contents of the program counter are pushed onto the
stack. At the end of a subroutine or an interrupt routine,
signaled by a return instruction (RET or RETI), the program counter is restored to its previous value from the
stack. After a chip reset, the SP will point to the top of the
stack.
The accumulator is closely related to ALU operations. It
is also mapped to location 05H of the data memory and
can carry out immediate data operations. The data
movement between two data memory locations must
pass through the accumulator.
0 0 H
In d ir e c t A d d r e s s in g R e g is te r
0 1 H
M P
0 2 H
0 3 H
0 4 H
0 5 H
If the stack is full and a non-masked interrupt takes
place, the interrupt request flag will be recorded but the
acknowledgment will be inhibited. When the stack
pointer is decremented (by RET or RETI), the interrupt
will be serviced. This feature prevents stack overflow allowing the programmer to use the structure more easily.
In a similar case, if the stack is full and a ²CALL² is subsequently executed, stack overflow occurs and the first
entry will be lost (only the most recent 6 return addresses are stored).
A C C
0 6 H
P C L
0 7 H
T B L P
0 8 H
T B L H
0 9 H
0 A H
S T A T U S
0 B H
IN T C 0
0 C H
0 D H
T M R
0 E H
T M R C
0 F H
1 0 H
1 1 H
1 2 H
P A
1 3 H
P A C
1 4 H
P B
Data Memory - RAM
1 5 H
P B C
1 6 H
P C
The data memory is designed with 92´8 bits. The data
memory is divided into two functional groups: special
function registers and general purpose data memory
(64´8). Most are read/write, but some are read only.
1 7 H
P C C
1 8 H
P D
1 9 H
P D C
1 A H
P W M
S p e c ia l P u r p o s e
D a ta M e m o ry
1 B H
The remaining space before the 40H is reserved for future expanded usage and reading these locations will
get ²00H². The general purpose data memory, addressed from 40H to 7FH, is used for data and control
information under instruction commands. All of the data
memory areas can handle arithmetic, logic, increment, decrement and rotate operations directly. Except for some dedicated bits, each bit in the data memory can be set and reset
by ²SET [m].i² and ²CLR [m].i². They are also indirectly
accessible through memory pointer register (MP;01H).
1 C H
1 D H
1 E H
IN T C 1
1 F H
2 0 H
H A D R
2 1 H
H C R
2 2 H
H S R
2 3 H
H D R
2 4 H
A D R L
2 5 H
A D R H
2 6 H
A D C R
2 7 H
A C S R
2 8 H
Indirect Addressing Register
2 9 H
Location 00H is an indirect addressing register that is
not physically implemented. Any read/write operation of
[00H] accesses data memory pointed to by MP (01H).
Reading location 00H itself indirectly will return the result 00H. Writing indirectly results in no operation.
The memory pointer register MP (01H) is a 7-bit register.
The bit 7 of MP is undefined and reading will return the
result ²1². Any writing operation to MP will only transfer
the lower 7-bit data to MP.
2 A H
U S R
2 B H
U C R 1
2 C H
U C R 2
2 D H
T X R /R X R
2 E H
3 0 H
B R G
3 F H
4 0 H
7 F H
G e n e ra l P u rp o s e
D a ta M e m o ry
(6 4 B y te s )
: U n u s e d
R e a d a s "0 0 "
RAM Mapping
Rev. 1.21
8
December 29, 2008
HT46RU22
Arithmetic and Logic Unit - ALU
pushed onto the stack automatically. If the contents of
the status are important and if the subroutine can corrupt the status register, precautions must be taken to
save it properly.
This circuit performs 8-bit arithmetic and logic operations.
The ALU provides the following functions:
· Arithmetic operations (ADD, ADC, SUB, SBC, DAA)
· Logic operations (AND, OR, XOR, CPL)
Interrupt
· Rotation (RL, RR, RLC, RRC)
The device provides an external interrupt, an internal
timer/event counter interrupt, the A/D converter interrupt, the I2C Bus interrupts and an UART interrupt. The
interrupt control register 0 (INTC0;0BH) and interrupt
control register 1 (INTC1;1EH) contains the interrupt
control bits to set the enable or disable and the interrupt
request flags.
· Increment and Decrement (INC, DEC)
· Branch decision (SZ, SNZ, SIZ, SDZ ....)
The ALU not only saves the results of a data operation but
also changes the status register.
Status Register - STATUS
Once an interrupt subroutine is serviced, all the other interrupts will be blocked (by clearing the EMI bit). This
scheme may prevent any further interrupt nesting. Other
interrupt requests may happen during this interval but
only the interrupt request flag is recorded. If a certain interrupt requires servicing within the service routine, the
EMI bit and the corresponding bit of INTC0 and INTC1
may be set to allow interrupt nesting. If the stack is full,
the interrupt request will not be acknowledged, even if the
related interrupt is enabled, until the SP is decremented.
If immediate service is desired, the stack must be prevented from becoming full.
This 8-bit register (0AH) contains the 0 flag (Z), carry
flag (C), auxiliary carry flag (AC), overflow flag (OV),
power down flag (PDF), and watchdog time-out flag
(TO). It also records the status information and controls
the operation sequence.
With the exception of the TO and PDF flags, bits in
the status register can be altered by instructions like
most other registers. Any data written into the status
register will not change the TO or PDF flag. In addition operations related to the status register may give
different results from those intended. The TO flag
can be affected only by system power-up, a WDT
time-out or executing the ²CLR WDT² or ²HALT² instruction. The PDF flag can be affected only by executing the ²HALT² or ²CLR WDT² instruction or a
system power-up.
All these kinds of interrupts have a wake-up capability.
As an interrupt is serviced, a control transfer occurs by
pushing the program counter onto the stack, followed by
a branch to a subroutine at specified location in the program memory. Only the program counter is pushed onto
the stack. If the contents of the register or status register
(STATUS) are altered by the interrupt service program
which corrupts the desired control sequence, the contents should be saved in advance.
The Z, OV, AC and C flags generally reflect the status of
the latest operations.
In addition, on entering the interrupt sequence or executing the subroutine call, the status register will not be
Bit No.
Label
Function
0
C
C is set if the operation results in a carry during an addition operation or if a borrow does not
take place during a subtraction operation; otherwise C is cleared. C is also affected by a rotate through carry instruction.
1
AC
AC is set if the operation results in a carry out of the low nibbles in addition or no borrow from
the high nibble into the low nibble in subtraction; otherwise AC is cleared.
2
Z
3
OV
OV is set if the operation results in a carry into the highest-order bit but not a carry out of the
highest-order bit, or vice versa; otherwise OV is cleared.
4
PDF
PDF is cleared by system power-up or executing the ²CLR WDT² instruction. PDF is set by
executing the ²HALT² instruction.
5
TO
TO is cleared by system power-up or executing the ²CLR WDT² or ²HALT² instruction. TO is
set by a WDT time-out.
6, 7
¾
Unused bit, read as ²0²
Z is set if the result of an arithmetic or logic operation is 0; otherwise Z is cleared.
Status (0AH) Register
Rev. 1.21
9
December 29, 2008
HT46RU22
External interrupts are triggered by a high to low transition of INT and the related interrupt request flag (EIF; bit
4 of INTC0) will be set. When the interrupt is enabled,
the stack is not full and the external interrupt is active, a
subroutine call to location 04H will occur. The interrupt
request flag (EIF) and EMI bits will be cleared to disable
other interrupts.
slave address match (HAAS=²1²) or 1 byte of data
transfer is completed. When the interrupt is enabled, the
stack is not full and the HIF bit is set, a subroutine call to location 10H will occur. The related interrupt request flag
(HIF) will be reset and the EMI bit cleared to disable further
interrupts.
The UART Bus interrupt is initialized by setting the
UART Bus interrupt request flag, URF; bit 7 of the
INTC1 register, caused by transmit data register empty
(TXIF), received data available(RXIF), transmission idle
(TIDLE), Over run error (OERR) or Address detected.
When the interrupt is enabled, the stack is not full and
the TXIF, RXIF, TIDLE, OERR bit is set or an address is
detected, a subroutine call to location 014H will occur.
The related interrupt request flag, URF, will be reset and
the EMI bit cleared to disable further interrupts.
The internal timer/event counter interrupt is initialized by
setting the timer/event counter interrupt request flag
(TF; bit 5 of INTC0), caused by a timer overflow. When
the interrupt is enabled, the stack is not full and the TF
bit is set, a subroutine call to location 08H will occur. The
related interrupt request flag (TF) will be reset and the
EMI bit cleared to disable further interrupts.
The A/D converter interrupt is initialized by setting the
A/D converter request flag (ADF; bit 6 of INTC0),
caused by an end of A/D conversion. When the interrupt
is enabled, the stack is not full and the ADF is set, a subroutine call to location 0CH will occur. The related interrupt request flag (ADF) will be reset and the EMI bit
cleared to disable further interrupts.
During the execution of an interrupt subroutine, other interrupt acknowledgments are held until the ²RETI² instruction is executed or the EMI bit and the related
interrupt control bit are set to 1 (of course, if the stack is
not full). To return from the interrupt subroutine, ²RET² or
²RETI² may be invoked. RETI will set the EMI bit to enable an interrupt service, but RET will not.
The I2C Bus interrupt is initialized by setting the I2C Bus
interrupt request flag (HIF; bit 4 of INTC1), caused by a
Bit No.
Label
Function
0
EMI
Controls the master (global) interrupt (1= enabled; 0= disabled)
1
EEI
Controls the external interrupt (1= enabled; 0= disabled)
2
ETI
3
EADI
Controls the timer/event counter interrupt (1= enabled; 0= disabled)
4
EIF
External interrupt request flag (1= active; 0= inactive)
5
TF
Internal timer/event counter request flag (1= active; 0= inactive)
6
ADF
7
¾
Controls the A/D converter interrupt (1= enabled; 0= disabled)
A/D converter request flag (1= active; 0= inactive)
For test mode used only.
Must be written as ²0²; otherwise may result in unpredictable operation.
INTC0 (0BH) Register
Bit No.
Label
Function
2
Controls the I C Bus interrupt (1=enabled; 0=disabled)
0
EHI
1
EURI
2~3, 6~7
¾
4
HIF
I2C Bus interrupt request flag (1=active; 0=inactive)
5
URF
UART request flag ( 1=active; 0:inactive )
Control the UART interrupt ( 1=enable ; 0=disable )
Unused bit, read as ²0²
INTC1 (1EH) Register
Rev. 1.21
10
December 29, 2008
HT46RU22
mode stops the system oscillator and ignores an external signal to conserve power.
Interrupts, occurring in the interval between the rising
edges of two consecutive T2 pulses, will be serviced on
the latter of the two T2 pulses, if the corresponding interrupts are enabled. In the case of simultaneous requests
the following table shows the priority that is applied.
These can be masked by resetting the EMI bit.
Priority
Vector
External Interrupt
Interrupt Source
1
04H
Timer/Event Counter Overflow
2
08H
A/D Converter Interrupt
3
0CH
I C Bus Interrupt
4
10H
UART Interrupt
5
14H
2
If an RC oscillator is used, an external resistor between
OSC1 and VSS is required and the resistance must
range from 24kW to 1MW. The system clock, divided by
4, is available on OSC2 with pull-high resistor, which
can be used to synchronize external logic. The RC oscillator provides the most cost effective solution. However, the frequency of oscillation may vary with VDD,
temperatures and the chip itself due to process variations. It is, therefore, not suitable for timing sensitive
operations where an accurate oscillator frequency is
desired.
If the Crystal oscillator is used, a crystal across OSC1
and OSC2 is needed to provide the feedback and phase
shift required for the oscillator, and no other external
components are required. Instead of a crystal, a resonator can also be connected between OSC1 and OSC2 to
get a frequency reference, but two external capacitors in
OSC1 and OSC2 are required (If the oscillating frequency is less than 1MHz).
Once the interrupt request flags, composed of TF, EIF,
ADF and HIF, are set, they will remain in the INTC0 and
INTC1 register until the interrupts are serviced or
cleared by a software instruction.
It is recommended that a program does not use the
²CALL subroutine² within the interrupt subroutine. Interrupts often occur in an unpredictable manner or need to
be serviced immediately in some applications. If only one
stack is left and enabling the interrupt is not well controlled, the original control sequence will be damaged
once the ²CALL² operates in the interrupt subroutine.
The WDT oscillator is a free running on-chip RC oscillator,
and no external components are required. Even if the system enters the power down mode, the system clock is
stopped, but the WDT oscillator still works with a period of
approximately 65ms at 5V. The WDT oscillator can be disabled by options to conserve power.
Oscillator Configuration
Watchdog Timer - WDT
There are two oscillator circuits in the microcontroller.
V
O S C 1
D D
4 7 0 p F
fS
O S C 2
Y S
The clock source of the WDT is implemented by an dedicated RC oscillator (WDT oscillator) or instruction clock
(system clock divided by 4) decided by options. This
timer is designed to prevent a software malfunction or
sequence jumping to an unknown location with unpredictable results. The watchdog Timer can be disabled by
an option. If the watchdog Timer is disabled, all the executions related to the WDT result in no operation.
O S C 1
O S C 2
/4
C r y s ta l O s c illa to r
R C
O s c illa to r
System Oscillator
Once an internal WDT oscillator (RC oscillator with period 65ms at 5V normally) is selected, it is divided by
212~215 (by option to get the WDT time-out period). The
minimum period of WDT time-out period is about
300ms~600ms. This time-out period may vary with tem-
Both are designed for system clocks, namely the RC oscillator and the Crystal oscillator, which are determined
by the options. No matter what oscillator type is selected, the signal provides the system clock. The HALT
S y s te m
C lo c k /4
O p tio n
S e le c t
W D T
O S C
fS
D iv id e r
fS /2
8
W D T P r e s c a le r
M a s k O p tio n
W D T C le a r
C K
R
T
C K
R
T
T im e
2 1 5/fS
2 1 4/fS
2 1 3/fS
2 1 2/fS
-o
~
~
~
~
u t
2 1
2 1
2 1
2 1
R e s e t
/fS
5
/fS
4
/fS
3
/fS
6
Watchdog Timer
Rev. 1.21
11
December 29, 2008
HT46RU22
perature, VDD and process variations. By selection the
WDT options, longer time-out periods can be realized. If
the WDT time-out is selected 215, the maximum time-out
period is divided by 215~216about 2.1s~4.3s.
The system can leave the HALT mode by means of an
external reset, an interrupt, an external falling edge signal on port A or a WDT overflow. An external reset
causes a device initialization and the WDT overflow performs a ²warm reset². After the TO and PDF flags are
examined, the reason for chip reset can be determined.
If the WDT oscillator is disabled, the WDT clock may still
come from the instruction clock and operate in the same
manner except that in the halt state the WDT may stop
counting and lose its protecting purpose. In this situation
the logic can only be restarted by external logic. If the
device operates in a noisy environment, using the
on-chip RC oscillator (WDT OSC) is strongly recommended, since the HALT will stop the system clock.
The PDF flag is cleared by system power-up or executing the ²CLR WDT² instruction and is set when executing the ²HALT² instruction. The TO flag is set if the WDT
time-out occurs, and causes a wake-up that only resets
the program counter and stack pointer; the others keep
their original status.
The WDT overflow under normal operation will initialize
²chip reset² and set the status bit TO. Whereas in the
HALT mode, the overflow will initialize a ²warm reset² only
the program counter and stack pointer are reset to 0. To
clear the contents of WDT, three methods are adopted; external reset (a low level to RES), software instructions, or a
HALT instruction. The software instructions include CLR
WDT and the other set - CLR WDT1 and CLR WDT2. Of
these two types of instruction, only one can be active depending on the options - ²CLR WDT times selection option². If the ²CLR WDT² is selected (i.e. CLRWDT times
equal 1), any execution of the CLR WDT instruction will
clear the WDT. In case ²CLR WDT1² and ²CLR WDT2²
are chosen (i.e. CLRWDT times equal two), these two instructions must be executed to clear the WDT; otherwise,
the WDT may reset the chip because of time-out.
The port A wake-up and interrupt methods can be considered as a continuation of normal execution. Each bit
in port A can be independently selected to wake up the
device by the options. Awakening from an I/O port stimulus, the program will resume execution of the next instruction. If it is awakening from an interrupt, two
sequences may happen. If the related interrupt is disabled or the interrupt is enabled but the stack is full, the
program will resume execution at the next instruction. If
the interrupt is enabled and the stack is not full, the regular interrupt response takes place. If an interrupt request
flag is set to ²1² before entering the HALT mode, the
wake-up function of the related interrupt will be disabled.
Once a wake-up event occurs, it takes 1024 tSYS (system clock period) to resume normal operation. In other
words, a dummy period will be inserted after wake-up. If
the wake-up results from an interrupt acknowledgment,
the actual interrupt subroutine execution will be delayed
by one or more cycles. If the wake-up results in the next
instruction execution, this will be executed immediately
after the dummy period is finished.
If the WDT time-out period is selected fs/212 (options), the
WDT time-out period ranges from fs/212~fs/213, since the
²CLR WDT² or ²CLR WDT1² and ²CLR WDT2² instructions only clear the last two stages of the WDT.
Power Down Operation - HALT
To minimize power consumption, all the I/O pins should
be carefully managed before entering the HALT status.
The HALT mode is initialized by the ²HALT² instruction
and results in the following...
· The system oscillator will be turned off but the WDT
oscillator keeps running (if the WDT oscillator is selected).
· The contents of the on chip RAM and registers remain
unchanged.
· WDT will be cleared and recounted again (if the WDT
clock is from the WDT oscillator).
· All of the I/O ports maintain their original status.
· The PDF flag is set and the TO flag is cleared.
Rev. 1.21
12
December 29, 2008
HT46RU22
V
Reset
V
D D
0 .0 1 m F
There are three ways in which a reset can occur:
· RES reset during normal operation
1 0 0 k W
1 0 0 k W
· RES reset during HALT
R E S
· WDT time-out reset during normal operation
PDF
0
0
RES reset during power-up
u
u
RES reset during normal operation
0
1
RES wake-up HALT
1
u
WDT time-out during normal operation
1
1
WDT wake-up HALT
B a s ic
R e s e t
C ir c u it
1 0 k W
H i-n o is e
R e s e t
C ir c u it
0 .1 m F
Reset Circuit
Note:
Most applications can use the Basic Reset Circuit as shown, however for applications with
extensive noise, it is recommended to use the
Hi-noise Reset Circuit.
RESET Conditions
V D D
R E S
tS
C h ip
R e s e t
Reset Timing Chart
To guarantee that the system oscillator is started and
stabilized, the SST (System Start-up Timer) provides an
extra-delay of 1024 system clock pulses when the system reset (power-up, WDT time-out or RES reset) or the
system awakes from the HALT state.
H A L T
O S C 1
The functional unit chip reset status are shown below.
Interrupt
Disable
WDT
Clear after master reset,
WDT begins counting
Timer/Event Counter
Off
Input/Output ports
Input mode
Stack Pointer
Points to the top of the stack
R e s e t
R E S
An extra option load time delay is added during system
reset (power-up, WDT time-out at normal mode or RES
reset).
000H
W a rm
W D T
When a system reset occurs, the SST delay is added
during the reset period. Any wake-up from HALT will enable the SST delay.
Program Counter
S T
S S T T im e - o u t
Note: ²u² means unchanged
Rev. 1.21
R E S
0 .1 m F
The WDT time-out during HALT is different from other
chip reset conditions, since it can perform a ²warm re set² that resets only the program counter and SP, leaving the other circuits in their original state. Some registers remain unchanged during other reset conditions.
Most registers are reset to the ²initial condition² when
the reset conditions are met. By examining the PDF and
TO flags, the program can distinguish between different
²chip resets².
TO
D D
C o ld
R e s e t
S S T
1 0 - b it R ip p le
C o u n te r
S y s te m
R e s e t
Reset Configuration
13
December 29, 2008
HT46RU22
The registers states are summarized in the following table.
Register
Reset
(Power On)
WDT Time-out
RES Reset
(Normal Operation) (Normal Operation)
RES Reset
(HALT)
WDT Time-out
(HALT)*
TMR
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
uuuu uuuu
TMRC
00-0 1000
00-0 1000
00-0 1000
00-0 1000
uu-u uuuu
000H
000H
000H
000H
000H
MP
-xxx xxxx
-uuu uuuu
-uuu uuuu
-uuu uuuu
-uuu uuuu
ACC
xxxx xxxx
uuuu uuuu
uuuu uuuu
uuuu uuuu
uuuu uuuu
TBLP
xxxx xxxx
uuuu uuuu
uuuu uuuu
uuuu uuuu
uuuu uuuu
TBLH
--xx xxxx
--uu uuuu
--uu uuuu
--uu uuuu
--uu uuuu
STATUS
--00 xxxx
--1u uuuu
--uu uuuu
--01 uuuu
--11 uuuu
INTC0
-000 0000
-000 0000
-000 0000
-000 0000
-uuu uuuu
INTC1
--xx --xx
--xx --xx
--xx --xx
--xx --xx
--uu --uu
PA
1111 1111
1111 1111
1111 1111
1111 1111
uuuu uuuu
PAC
1111 1111
1111 1111
1111 1111
1111 1111
uuuu uuuu
PB
1111 1111
1111 1111
1111 1111
1111 1111
uuuu uuuu
PBC
1111 1111
1111 1111
1111 1111
1111 1111
uuuu uuuu
PC
---- --11
---- --11
---- --11
---- --11
---- --uu
PCC
---- --11
---- --11
---- --11
---- --11
---- --uu
PD
---- ---1
---- ---1
---- ---1
---- ---1
---- ---u
PDC
---- ---1
---- ---1
---- ---1
---- ---1
---- ---u
PWM
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
uuuu uuuu
HADR
xxxx xxx-
xxxx xxx-
xxxx xxx-
xxxx xxx-
uuuu uuu-
Program
Counter
HCR
0--0 0---
0--0 0---
0--0 0---
0--0 0---
u--u u---
HSR
100- -0-1
100- -0-1
100- -0-1
100- -0-1
uuu- -u-u
HDR
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
uuuu uuuu
ADRL
x--- ----
x--- ----
x--- ----
x--- ----
u--- ----
ADRH
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
uuuu uuuu
ADCR
0100 0000
0100 0000
0100 0000
0100 0000
uuuu uuuu
ACSR
1--- --00
1--- --00
1--- --00
1--- --00
u--- --uu
USR
0000 1011
0000 1011
0000 1011
0000 1011
uuuu uuuu
UCR1
0000 00x0
0000 00x0
0000 00x0
0000 00x0
uuuu uuuu
UCR2
0000 0000
0000 0000
0000 0000
0000 0000
uuuu uuuu
TXR/RXR
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
uuuu uuuu
BGR
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
uuuu uuuu
Note:
²*² stands for warm reset
²u² stands for unchanged
²x² stands for unknown
Rev. 1.21
14
December 29, 2008
HT46RU22
Timer/Event Counter
In the event count or timer mode, once the timer/event
counter starts counting, it will count from the current
contents in the timer/event counter to FFH. Once overflow occurs, the counter is reloaded from the timer/event
counter preload register and generates the interrupt request flag (TF; bit 5 of INTC0) at the same time.
A timer/event counter (TMR) is implemented in the
microcontroller. The timer/event counter contains an 8-bit
programmable count-up counter and the clock may come
from an external source or the system clock.
Using the internal system clock, there is only one reference time-base. The internal clock source comes from
fSYS. Using external clock input allows the user to count
external events, measure time internals or pulse widths,
or generate an accurate time base. While using the internal clock allows the user to generate an accurate time
base.
In the pulse width measurement mode with the TON and
TE bits equal to 1, once the TMR has received a transient from low to high (or high to low if the TE bits is ²0²)
it will start counting until the TMR returns to the original
level and resets the TON. The measured result will remain in the timer/event counter even if the activated
transient occurs again. In other words, only 1 cycle measurement can be done. Until setting the TON, the cycle
measurement will function again as long as it receives
further transient pulse. Note that, in this operating mode,
the timer/event counter starts counting not according to
the logic level but according to the transient edges. In
the case of counter overflows, the counter is reloaded
from the timer/event counter preload register and issues
the interrupt request just like the other two modes. To
enable the counting operation, the timer ON bit (TON;
bit 4 of TMRC) should be set to 1. In the pulse width
measurement mode, the TON will be cleared automatically after the measurement cycle is completed. But in
the other two modes the TON can only be reset by instructions. The overflow of the timer/event counter is
one of the wake-up sources. No matter what the operation mode is, writing a 0 to ETI can disable the interrupt
service.
There are two registers related to the timer/event counter; TMR ([0DH]), TMRC ([0EH]). Two physical registers
are mapped to TMR location; writing TMR makes the
starting value be placed in the timer/event counter
preload register and reading TMR gets the contents of
the timer/event counter. The TMRC is a timer/event
counter control register, which defines some options.
The TM0, TM1 bits define the operating mode. The
event count mode is used to count external events,
which means the clock source comes from an external
(TMR) pin. The timer mode functions as a normal timer
with the clock source coming from the fINT clock. The
pulse width measurement mode can be used to count the
high or low level duration of the external signal (TMR). The
counting is based on the fINT.
Bit No.
0
1
2
Label
PSC0
PSC1
PSC2
3
TE
4
TON
5
¾
6
7
TM0
TM1
Function
To define the prescaler stages, PSC2, PSC1, PSC0=
000: fINT=fSYS
001: fINT=fSYS/2
010: fINT=fSYS/4
011: fINT=fSYS/8
100: fINT=fSYS/16
101: fINT=fSYS/32
110: fINT=fSYS/64
111: fINT=fSYS/128
Defines the TMR active edge of the timer/event counter:
In Event Counter Mode (TM1,TM0)=(0,1):
1:count on falling edge;
0:count on rising edge
In Pulse Width measurement mode (TM1,TM0)=(1,1):
1: start counting on the rising edge, stop on the falling edge;
0: start counting on the falling edge, stop on the rising edge
To enable or disable timer counting
(0=disabled; 1=enabled)
Unused bit, read as ²0²
To define the operating mode
01=Event count mode (external clock)
10=Timer mode (internal clock)
11=Pulse width measurement mode
00=Unused
TMRC (0EH) Register
Rev. 1.21
15
December 29, 2008
HT46RU22
P W M
(6 + 2 ) o r (7 + 1 )
C o m p a re
fS
Y S
T o P D 0 C ir c u it
8 - s ta g e P r e s c a le r
f IN
8 -1 M U X
P S C 2 ~ P S C 0
D a ta B u s
T
T M 1
T M 0
T M R
8 - B it T im e r /E v e n t
C o u n te r P r e lo a d
R e g is te r
R e lo a d
T E
T M 1
T M 0
T O N
8 - B it T im e r /E v e n t
C o u n te r
P u ls e W id th
M e a s u re m e n t
M o d e C o n tro l
O v e r flo w
1 /2
to In te rru p t
P F D
Timer/Event Counter
For output function, CMOS is the only configuration.
These control registers are mapped to locations 13H,
15H, 17H and 19H.
In the case of timer/event counter OFF condition, writing data to the timer/event counter preload register will
also reload that data to the timer/event counter. But if the
timer/event counter is turned on, data written to it will
only be kept in the timer/event counter preload register.
The timer/event counter will still operate until overflow occurs. When the timer/event counter (reading TMR) is read,
the clock will be blocked to avoid errors. As clock blocking
may results in a counting error, this must be taken into consideration by the programmer.
After a chip reset, these input/output lines remain at high
levels or floating state (dependent on pull-high options).
Each bit of these input/output latches can be set or
cleared by ²SET [m].i² and ²CLR [m].i² (m=12H, 14H,
16H or 18H) instructions.
Some instructions first input data and then follow the
output operations. For example, ²SET [m].i², ²CLR
[m].i², ²CPL [m]², ²CPLA [m]² read the entire port states
into the CPU, execute the defined operations
(bit-operation), and then write the results back to the
latches or the accumulator.
The bit0~bit2 of the TMRC can be used to define the
pre-scaling stages of the internal clock sources of
timer/event counter. The definitions are as shown. The
overflow signal of timer/event counter can be used to
generate the PFD signal.
Each line of port A has the capability of waking-up the
device. The highest 6-bit of port C and 7-bit of port D are
not physically implemented; on reading them a ²0² is returned whereas writing then results in a no-operation.
See Application note.
Input/Output Ports
There are 19 bidirectional input/output lines in the
microcontroller, labeled as PA, PB, PC and PD, which
are mapped to the data memory of [12H], [14H], [16H]
and [18H] respectively. All of these I/O ports can be
used for input and output operations. For input operation, these ports are non-latching, that is, the inputs
must be ready at the T2 rising edge of instruction ²MOV
A,[m]² (m=12H, 14H, 16H or 18H). For output operation,
all the data is latched and remains unchanged until the
output latch is rewritten.
Each I/O port has a pull-high option. Once the pull-high
option is selected, the I/O port has a pull-high resistor,
otherwise, there¢s none. Take note that a non-pull-high
I/O port operating in input mode will cause a floating
state.
The PA3 is pin-shared with the PFD signal. If the PFD
option is selected, the output signal in output mode of
PA3 will be the PFD signal generated by timer/event
counter overflow signal. The input mode always remaining its original functions. Once the PFD option is selected, the PFD output signal is controlled by PA3 data
register only. Writing ²1² to PA3 data register will enable
the PFD output function and writing ²0² will force the
PA3 to remain at ²0².
Each I/O line has its own control register (PAC, PBC,
PCC, PDC) to control the input/output configuration.
With this control register, CMOS output or Schmitt trigger input with or without pull-high resistor structures can
be reconfigured dynamically (i.e. on-the-fly) under software control. To function as an input, the corresponding
latch of the control register must write ²1². The input
source also depends on the control register. If the control register bit is ²1², the input will read the pad state. If
the control register bit is ²0², the contents of the latches
will move to the internal bus. The latter is possible in the
²read-modify-write² instruction.
Rev. 1.21
16
December 29, 2008
HT46RU22
V
C o n tr o l B it
D a ta B u s
W r ite C o n tr o l R e g is te r
Q
D
C K
Q
S
C h ip R e s e t
D D
P u ll- h ig h
O p tio n
P A
P A
P A
P A
P A
P A
P B
P D
R e a d C o n tr o l R e g is te r
D a ta B it
Q
D
W r ite D a ta R e g is te r
C K
A 2
F D
M R
T
D A
C L
N 0 ~ P B 7 /A N 7
W M
Q
S
M
(P D 0 o r P W M ) P A 3
P F D
M
R e a d D a ta R e g is te r
S y s te m
0 ~ P
3 /P
4 /T
5 /IN
6 /S
7 /S
0 /A
0 /P
U
U
X
P F D E N
(P A 3 )
X
W a k e - u p ( P A o n ly )
O P 0 ~ O P 7
IN T fo r P A 5 O n ly
T M R
fo r P A 4 O n ly
Input/Output Ports
V
D a ta B u s
W r ite C o n tr o l R e g is te r
Q
D
C K
D D
P u ll- h ig h
O p tio n
C o n tr o l B it
Q
S
C h ip R e s e t
P C 0 /T X
R e a d C o n tr o l R e g is te r
W r ite D a ta R e g is te r
D a ta B it
Q
D
C K
Q
S
M
F ro m
U A R T T X
M
R e a d D a ta R e g is te r
U
U
X
U A R T E N
X
& T X E N
PC0/TX Input/Output Ports
V
C o n tr o l B it
D a ta B u s
W r ite C o n tr o l R e g is te r
Q
D
C K
D D
P u ll- h ig h
O p tio n
S
Q
C h ip R e s e t
R e a d C o n tr o l R e g is te r
W r ite D a ta R e g is te r
P C 1 /R X
D a ta B it
Q
D
C K
S
Q
M
R e a d D a ta R e g is te r
U
X
T o U A R T R X
PC1/RX Input/Output Ports
Rev. 1.21
17
December 29, 2008
HT46RU22
In a (6+2) bit PWM function, the contents of the PWM
register is divided into two groups. Group 1 of the PWM
register is denoted by DC which is the value of
PWM.7~PWM.2. The group 2 is denoted by AC which is
the value of PWM.1~PWM.0.
The I/O functions of PA3 are shown below.
I/O
Mode
Logical
Input
PA3
Note:
I/P
O/P
(Normal) (Normal)
Logical
Output
I/P
(PFD)
O/P
(PFD)
Logical
PFD
Input (Timer on)
In a (6+2) bits mode PWM cycle, the duty cycle of each
modulation cycle is shown in the table.
The PFD frequency is the timer/event counter
overflow frequency divided by 2.
Parameter
AC (0~3)
Duty Cycle
i<AC
DC + 1
64
i³AC
DC
64
The PA5 and PA4 are pin-shared with INT and TMR pins
respectively.
Modulation cycle i
(i=0~3)
The PB can also be used as A/D converter inputs. The
A/D function will be described later. There is a PWM
function shared with PD0. If the PWM function is enabled, the PWM signal will appear on PD0 (if PD0 is operating in output mode). Writing ²1² to PD0 data register
will enable the PWM output function and writing ²0² will
force the PD0 to remain at ²0². The I/O functions of PD0
is as shown.
I/O
I/P
Mode (Normal)
PD0
Logical
Input
O/P
(Normal)
I/P
(PWM)
O/P
(PWM)
Logical
Output
Logical
Input
PWM
A (7+1) bits mode PWM cycle is divided into two modulation cycles (modulation cycle 0 ~ modulation cycle 1).
Each modulation cycle has 128 PWM input clock period.
In a (7+1) bits PWM function, the contents of the PWM
register is divided into two groups. Group 1 of the PWM
register is denoted by DC which is the value of
PWM.7~PWM.1. The group 2 is denoted by AC which is
the value of PWM.0.
In a (7+1) bits mode PWM cycle, the duty cycle of each
modulation cycle is shown in the table.
It is recommended that unused or not bonded out I/O
lines should be set as output pins by software instruction
to avoid consuming power under input floating state.
Parameter
AC (0~1)
Duty Cycle
i<AC
DC + 1
128
i³AC
DC
128
Modulation cycle i
(i=0~1)
PWM
The microcontroller provides 1 channels (6+2)/(7+1)
(dependent on options) bits PWM output shared with
PD0. The PWM channel has its data registers denoted
as PWM(1AH). The frequency source of the PWM counter comes from fSYS. The PWM registers is a 8-bit register. The waveforms of PWM outputs are as shown.
Once the PD0 is selected as the PWM outputs and the
output function of PD0 is enabled (PDC.0=²0²), writing 1
to PD0 data register will enable the PWM output function and writing ²0² will force the PD0 to stay at ²0².
The modulation frequency, cycle frequency and cycle
duty of the PWM output signal are summarized in the
following table.
PWM
Modulation Frequency
fSYS/64 for (6+2) bits mode
fSYS/128 for (7+1) bits mode
PWM Cycle PWM Cycle
Frequency
Duty
fSYS/256
[PWM]/256
A (6+2) bits mode PWM cycle is divided into four modulation cycles (modulation cycle 0~modulation cycle 3).
Each modulation cycle has 64 PWM input clock period.
Rev. 1.21
18
December 29, 2008
HT46RU22
fS
/2
Y S
[P W M ] = 1 0 0
P W M
2 5 /6 4
2 5 /6 4
2 5 /6 4
2 5 /6 4
2 5 /6 4
2 6 /6 4
2 5 /6 4
2 5 /6 4
2 5 /6 4
2 6 /6 4
2 6 /6 4
2 6 /6 4
2 5 /6 4
2 5 /6 4
2 6 /6 4
2 6 /6 4
2 6 /6 4
2 5 /6 4
2 6 /6 4
[P W M ] = 1 0 1
P W M
[P W M ] = 1 0 2
P W M
[P W M ] = 1 0 3
P W M
2 6 /6 4
P W M
m o d u la tio n p e r io d : 6 4 /fS
M o d u la tio n c y c le 0
Y S
M o d u la tio n c y c le 1
P W M
M o d u la tio n c y c le 2
c y c le : 2 5 6 /fS
M o d u la tio n c y c le 3
M o d u la tio n c y c le 0
Y S
(6+2) PWM Mode
fS
Y S
/2
[P W M ] = 1 0 0
P W M
5 0 /1 2 8
5 0 /1 2 8
5 0 /1 2 8
5 1 /1 2 8
5 0 /1 2 8
5 1 /1 2 8
5 1 /1 2 8
5 1 /1 2 8
5 1 /1 2 8
5 1 /1 2 8
5 2 /1 2 8
[P W M ] = 1 0 1
P W M
[P W M ] = 1 0 2
P W M
[P W M ] = 1 0 3
P W M
5 2 /1 2 8
P W M
m o d u la tio n p e r io d : 1 2 8 /fS
Y S
M o d u la tio n c y c le 0
M o d u la tio n c y c le 1
P W M
c y c le : 2 5 6 /fS
M o d u la tio n c y c le 0
Y S
(7+1) PWM Mode
A/D Converter
The A/D converter control register is used to control the
A/D converter. The bit2~bit0 of the ADCR are used to
select an analog input channel. There are a total of eight
channels to select. The bit5~bit3 of the ADCR are used
to set PB configurations. PB can be an analog input or
as digital I/O line decided by these 3 bits. Once a PB line
is selected as an analog input, the I/O functions and
pull-high resistor of this I/O line are disabled and the A/D
converter circuit is power on. The EOCB bit (bit6 of the
ADCR) is end of A/D conversion flag. Check this bit to
know when A/D conversion is completed. The START
bit of the ADCR is used to begin the conversion of the
A/D converter. Giving START bit a rising edge and falling edge means that the A/D conversion has started. In
order to ensure the A/D conversion is completed, the
START should remain at ²0² until the EOCB is cleared to
²0² (end of A/D conversion).
The 8 channels and 9-bit resolution A/D converter are
implemented in this microcontroller. The reference voltage is VDD. The A/D converter contains 4 special registers which are; ADRL (24H), ADRH (25H), ADCR (26H)
and ACSR (27H). The ADRH and ADRL are A/D result
register higher-order byte and lower-order byte and are
read-only. After the A/D conversion is completed, the
ADRH and ADRL should be read to get the conversion
result data. The ADCR is an A/D converter control register, which defines the A/D channel number, analog
channel select, start A/D conversion control bit and the
end of A/D conversion flag. If the users want to start an
A/D conversion, define PB configuration, select the converted analog channel, and give START bit a raising
edge and falling edge (0®1®0). At the end of A/D conversion, the EOCB bit is cleared and an A/D converter
interrupt occurs (if the A/D converter interrupt is enabled). The ACSR is A/D clock setting register, which is
used to select the A/D clock source.
Rev. 1.21
19
December 29, 2008
HT46RU22
Bit No.
Label
Function
Selects the A/D converter clock source
00= system clock/2
ADCS0
01= system clock/8
ADCS1
10= system clock/32
11= undefined
0
1
2~6
¾
Unused bit, read as ²0²
7
TEST
For test mode used only
ACSR (27H) Register
Bit No.
Label
Function
0
1
2
ACS0
ACS1
ACS2
Defines the analog channel select.
3
4
5
PCR0
PCR1
PCR2
Defines the port B configuration select. If PCR0, PCR1 and PCR2 are all 0, the ADC circuit is
power off to reduce power consumption
6
EOCB
Indicates end of A/D conversion. (0 = end of A/D conversion)
Each time bits 3~5 change state the A/D should be initialized by issuing a START signal, otherwise the EOCB flag may have an undefined condition. See ²Important note for A/D initialization².
7
START Starts the A/D conversion. (0®1®0= start; 0®1= Reset A/D converter and set EOCB to ²1²)
ADCR (26H) Register
PCR2
PCR1
PCR0
7
6
5
4
3
2
1
0
0
0
0
PB7
PB6
PB5
PB4
PB3
PB2
PB1
PB0
0
0
1
PB7
PB6
PB5
PB4
PB3
PB2
PB1
AN0
0
1
0
PB7
PB6
PB5
PB4
PB3
PB2
AN1
AN0
0
1
1
PB7
PB6
PB5
PB4
PB3
AN2
AN1
AN0
1
0
0
PB7
PB6
PB5
PB4
AN3
AN2
AN1
AN0
1
0
1
PB7
PB6
PB5
AN4
AN3
AN2
AN1
AN0
1
1
0
PB7
PB6
AN5
AN4
AN3
AN2
AN1
AN0
1
1
1
AN7
AN6
AN5
AN4
AN3
AN2
AN1
AN0
Port B Configuration
ACS2
ACS1
ACS0
Analog Channel
0
0
0
AN0
0
0
1
AN1
0
1
0
AN2
0
1
1
AN3
1
0
0
AN4
1
0
1
AN5
1
1
0
AN6
1
1
1
AN7
Analog Input Channel Selection
Rev. 1.21
20
December 29, 2008
HT46RU22
Bit 7 of the ACSR register is used for test purposes only and must not be used for other purposes by the application program. Bit1 and bit0 of the ACSR register are used to select the A/D clock source.
When the A/D conversion has completed, the A/D interrupt request flag will be set. The EOCB bit is set to ²1² when the
START bit is set from ²0² to ²1².
Important Note for A/D initialization:
Special care must be taken to initialize the A/D converter each time the Port B A/D channel selection bits are modified,
otherwise the EOCB flag may be in an undefined condition. An A/D initialization is implemented by setting the START
bit high and then clearing it to zero within 10 instruction cycles of the Port B channel selection bits being modified. Note
that if the Port B channel selection bits are all cleared to zero then an A/D initialization is not required.
Register
Bit7
ADRL
D0
¾
¾
¾
¾
¾
¾
¾
ADRH
D8
D7
D6
D5
D4
D3
D2
D1
Note:
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
D0~D8 is A/D conversion result data bit LSB~MSB.
ADRL (24H), ADRH (25H) Register
The following two programming examples illustrate how to setup and implement an A/D conversion. In the first example, the method of polling the EOCB bit in the ADCR register is used to detect when the conversion cycle is complete,
whereas in the second example, the A/D interrupt is used to determine when the conversion is complete.
Example: using EOCB Polling Method to detect end of conversion
clr
mov
mov
mov
mov
EADI
a,00000001B
ACSR,a
a,00100000B
ADCR,a
:
:
:
Start_conversion:
clr
START
set
START
clr
START
Polling_EOC:
sz
EOCB
jmp
polling_EOC
mov
a,ADRH
mov
adrh_buffer,a
mov
a,ADRL
mov
adrl_buffer,a
:
:
jmp
start_conversion
; disable ADC interrupt
; setup the ACSR register to select fSYS/8 as the A/D clock
; setup ADCR register to configure Port PB0~PB3 as A/D inputs
; and select AN0 to be connected to the A/D converter
; As the Port B channel bits have changed the following START
; signal (0-1-0) must be issued within 10 instruction cycles
; reset A/D
; start A/D
; poll the ADCR register EOCB bit to detect end of A/D conversion
; continue polling
; read conversion result high byte value from the ADRH register
; save result to user defined memory
; read conversion result low byte value from the ADRL register
; save result to user defined memory
; start next A/D conversion
Example: using interrupt method to detect end of conversion
clr
EADI
; disable ADC interrupt
mov
a,00000001B
mov
ACSR,a
; setup the ACSR register to select fSYS/8 as the A/D clock
mov
mov
a,00100000B
ADCR,a
:
; setup ADCR register to configure Port PB0~PB3 as A/D inputs
; and select AN0 to be connected to the A/D converter
; As the Port B channel bits have changed the following START
; signal (0-1-0) must be issued within 10 instruction cycles
Rev. 1.21
21
December 29, 2008
HT46RU22
:
Start_conversion:
clr
START
set
START
clr
START
clr
ADF
set
EADI
set
EMI
:
:
:
; ADC interrupt service routine
ADC_ISR:
mov
acc_stack,a
mov
a,STATUS
mov
status_stack,a
:
:
mov
a,ADRH
mov
adrh_buffer,a
mov
a,ADRL
mov
adrl_buffer,a
clr
START
set
START
clr
START
:
:
EXIT_INT_ISR:
mov
a,status_stack
mov
STATUS,a
mov
a,acc_stack
reti
M in im u m
; reset A/D
; start A/D
; clear ADC interrupt request flag
; enable ADC interrupt
; enable global interrupt
; save ACC to user defined memory
; save STATUS to user defined memory
; read conversion result high byte value from the ADRH register
; save result to user defined register
; read conversion result low byte value from the ADRL register
; save result to user defined register
; reset A/D
; start A/D
; restore STATUS from user defined memory
; restore ACC from user defined memory
o n e in s tr u c tio n c y c le n e e d e d , M a x im u m
te n in s tr u c tio n c y c le s a llo w e d
S T A R T
E O C B
A /D
tA
P C R 2 ~
P C R 0
s a m p lin g tim e
A /D
tA
D C S
0 0 0 B
s a m p lin g tim e
A /D s a m p lin g tim e
tA D C S
D C S
1 0 0 B
1 0 0 B
1 0 1 B
0 0 0 B
1 . P B p o rt s e tu p a s I/O s
2 . A /D c o n v e r te r is p o w e r e d o ff
to r e d u c e p o w e r c o n s u m p tio n
A C S 2 ~
A C S 0
0 0 0 B
P o w e r-o n
R e s e t
0 1 0 B
0 0 0 B
0 0 1 B
S ta rt o f A /D
c o n v e r s io n
S ta rt o f A /D
c o n v e r s io n
S ta rt o f A /D
c o n v e r s io n
R e s e t A /D
c o n v e rte r
R e s e t A /D
c o n v e rte r
E n d o f A /D
c o n v e r s io n
1 : D e fin e P B c o n fig u r a tio n
2 : S e le c t a n a lo g c h a n n e l
A /D
N o te :
A /D
tA D
tA
C S
D C
c lo c k m u s t b e fS
= 3 2 tA D
= 7 6 tA D
Y S
/2 , fS
tA D C
c o n v e r s io n tim e
Y S
/8 o r fS
Y S
R e s e t A /D
c o n v e rte r
E n d o f A /D
c o n v e r s io n
A /D
tA D C
c o n v e r s io n tim e
d o n 't c a r e
E n d o f A /D
c o n v e r s io n
A /D
tA D C
c o n v e r s io n tim e
/3 2
A/D Conversion Timing
Rev. 1.21
22
December 29, 2008
HT46RU22
Low Voltage Reset - LVR
I2C Bus Serial Interface
The microcontroller provides low voltage reset circuit in
order to monitor the supply voltage of the device. If the
supply voltage of the device is within the range
0.9V~3.3V, such as changing a battery, the LVR will automatically reset the device internally.
I2C Bus is implemented in the device. The I2C Bus is a
bidirectional 2-wire lines. The data line and clock line
are implement in SDA pin and SCL pin. The SDA and
SCL are NMOS open drain output pin. They must connect a pull-high resistor respectively.
The LVR includes the following specifications:
Using the I2C Bus, the device has two ways to transfer
data. One is in slave transmit mode, the other is in slave
receive mode. There are four registers related to I2C
Bus; HADR([20H]), HCR([21H]), HSR([22H]),
HDR([23H]). The HADR register is the slave address
setting of the device, if the master sends the calling address which match, it means that this device is selected.
The HCR is I2C Bus control register which defines the
device enable or disable the I2C Bus as a transmitter or
as a receiver. The HSR is I2C Bus status register, it responds with the I2C Bus status. The HDR is input/output
data register, data to transmit or receive must be via the
HDR register.
· The low voltage (0.9V~VLVR) has to remain in their
original state to exceed 1ms. If the low voltage state
does not exceed 1ms, the LVR will ignore it and do not
perform a reset function.
· The LVR uses the ²OR² function with the external RES
signal to perform chip reset.
The relationship between VDD and VLVR is shown below.
V D D
5 .5 V
V
O P R
5 .5 V
V
The I2C Bus control register contains three bits. The
HEN bit define the enable or disable the I2C Bus. If the
data wants transfer via I2C Bus, this bit must be set. The
HTX bit defines whether the I2C Bus is in transmit or receive mode. If the device is as a transmitter, this bit must
be set to ²1². The TXAK defines the transmit acknowledge signal, when the device received 8-bit data, the
device sends this bit to I2C Bus at the 9th clock. If the receiver wants to continue to receive the next data, this bit
must be reset to ²0² before receiving data.
L V R
3 .0 V
2 .2 V
0 .9 V
Note: VOPR is the voltage range for proper chip
operation at 4MHz system clock.
V
D D
5 .5 V
V
L V R
L V R
D e te c t V o lta g e
0 .9 V
0 V
R e s e t S ig n a l
N o r m a l O p e r a tio n
R e s e t
*1
R e s e t
*2
Low Voltage Reset
Note:
*1: To make sure that the system oscillator has stabilized, the SST provides an extra delay of 1024 system
clock pulses before entering the normal operation.
*2: Since low voltage state has to be maintained in its original state for over 1ms, therefore after 1ms delay,
the device enters the reset mode.
Rev. 1.21
23
December 29, 2008
HT46RU22
The I2C Bus status register contains 5 bits. The HCF bit
is reset to ²0² when one data byte is being transferred. If
one data transfer is completed, this bit is set to ²1². The
HASS bit is set ²1² when the address is match, and the
I2C Bus interrupt request flag is set to ²1². If the interrupt
is enabled and the stack is not full, a subroutine call to
location 10H will occur. Writing data to the I2C Bus control register clears HAAS bit. If the address is not match,
this bit is reset to ²0². The HBB bit is set to respond the
I2C Bus is busy. It mean that a START signal is detected.
This bit is reset to ²0² when the I2C Bus is not busy. It
means that a STOP signal is detected and the I2C Bus is
free. The SRW bit defines the read/write command bit, if
the calling address is match. When HAAS is set to ²1²,
the device check SRW bit to determine whether the device is working in transmit or receive mode. When SRW
bit is set ²1², it means that the master wants to read data
from I2C Bus, the slave device must write data to I2C
Bus, so the slave device is working in transmit mode.
When SRW is reset to ²0², it means that the master
wants to write data to I2C Bus, the slave device must
read data from the bus, so the slave device is working in
receive mode. The RXAK bit is reset ²0² indicates an acknowledges signal has been received. In the transmit
mode, the transmitter checks RXAK bit to know the receiver which wants to receive the next data byte, so the
transmitter continue to write data to the I2C Bus until the
RXAK bit is set to ²1² and the transmitter releases the
SDA line, so that the master can send the STOP signal
to release the bus.
ister. At the beginning of the transfer of the I2C Bus, the
device must initial the bus, the following are the notes for
initialing the I2C Bus.
Note:
1: Write the I2C Bus address register (HADR) to define
its own slave address.
2: Set HEN bit of I2C Bus control register (HCR) bit 0 to
enable the I2C Bus.
Bit0
Slave Address
¾
Label
7
HEN
6~5
¾
4
HTX
3
2~0
To enable or disable I2C Bus function
(0= disable; 1= enable)
Unused bit, read as ²0²
To define the transmit or receive mode
(0= receive mode; 1= transmit)
To enable or disable transmit acknowlTXAK edge (0=acknowledge; 1=don¢t acknowledge)
¾
Unused bit, read as ²0²
3: Set EHI bit of the interrupt control register 1 (INTC1)
bit 0 to enable the I2C Bus interrupt.
Bit
Label
No.
7
5
HBB is set to ²1² when I2C Bus is busy
HBB and HBB is cleared to ²0² means that the
I2C Bus is not busy.
2
1
0
2
The HDR register is the I C Bus input/output data register. Before transmitting data, the HDR must write the
data which we want to transmit. Before receiving data,
the device must dummy read data from HDR. Transmit
or Receive data from I2C Bus must be via the HDR reg-
HCF is clear to ²0² when one data byte is
being transferred, HCF is set to ²1² indicating 8-bit data communication has
been finished.
HAAS is set to ²1² when the calling adHAAS dress has matched, and I2C Bus interrupt will occur and HIF is set.
4~3
HADR (20H) Register
HCF
Function
6
²¾² means undefined
Rev. 1.21
Function
HCR (21H) Register
The HADR bit7~bit1 define the device slave address. At
the beginning of transfer, the master must select a device by sending the address of the slave device. The bit
0 is unused and is not defined. If the I2C Bus receives a
start signal, all slave device notice the continuity of the
8-bit data. The front of 7 bits is slave address and the
first bit is MSB. If the address is match, the HAAS status
bit is set and generate an I2C Bus interrupt. In the ISR,
the slave device must check the HAAS bit to know the
I2C Bus interrupt comes from the slave address that has
match or completed one 8-bit data transfer. The last bit
of the 8-bit data is read/write command bit, it responds in
SRW bit. The slave will check the SRW bit to know if the
master wants to transmit or receive data. The device
check SRW bit to know it is as a transmitter or receiver.
Bit7~Bit1
Bit
No.
¾
Unused bit, read as ²0²
SRW is set to ²1² when the master
wants to read data from the I2C Bus, so
the slave must transmit data to the masSRW ter. SRW is cleared to ²0² when the master wants to write data to the I2C Bus, so
the slave must receive data from the
master.
¾
Unused bit, read as ²0²
RXAK is cleared to ²0² when the master
receives an 8-bit data and acknowledgRXAK
ment at the 9th clock, RXAK is set to ²1²
means not acknowledged.
HSR (22H) Register
24
December 29, 2008
HT46RU22
S ta rt
W r ite S la v e
A d d re s s to H A D R
S E T H E N
D is a b le
I2C B u s
In te rru p t= ?
E n a b le
C L R E H I
P o ll H IF to d e c id e
w h e n to g o to I2C B u s IS R
S E T E H I
W a it fo r In te r r u p t
G o to M a in P r o g r a m
G o to M a in P r o g r a m
S ta rt
N o
N o
R e a d fro m
Y e s
Y e s
H T X = 1
?
H D R
R E T I
Y e s
Y e s
H A A S = 1
?
R X A K = 1
?
N o
C L R H T X
C L R T X A K
W r ite to H D R
D u m m y R e a d
fro m H D R
R E T I
S R W = 1
?
N o
S E T H T X
C L R H T X
C L R T X A K
W r ite to H D R
D u m m y R e a d
F ro m H D R
R E T I
R E T I
R E T I
Rev. 1.21
25
December 29, 2008
HT46RU22
S C L
S R W
S la v e A d d r e s s
S ta rt
0
1
S D A
1
1
0
1
0
1
D a ta
S C L
1
0
0
1
A C K
0
A C K
0
1
0
S to p
0
S D A
S = S
S A =
S R =
M = S
D = D
A = A
P = S
S
ta rt (1
S la v e
S R W
la v e d
a ta (8
C K (R
to p (1
S A
b it)
A d d r e s s ( 7 b its )
b it ( 1 b it)
e v ic e s e n d a c k n o w le d g e b it ( 1 b it)
b its )
X A K b it fo r tr a n s m itte r , T X A K b it fo r r e c e iv e r 1 b it)
b it)
S R
M
D
A
D
A
S
S A
S R
M
D
A
D
A
P
I2C Communication Timing Diagram
In interrupt subroutine, check HAAS bit to know whether
the I2C Bus interrupt comes from a slave address that is
matched or a data byte transfer is completed. When the
slave address is matched, the device must be in transmit mode or receive mode and write data to HDR or
dummy read from HDR to release the SCL line.
Start Signal
The START signal is generated only by the master device. The other device in the bus must detect the START
signal to set the I2C Bus busy bit (HBB). The START signal is SDA line from high to low, when SCL is high.
S C L
SRW Bit
The SRW bit means that the master device wants to
read from or write to the I2C Bus. The slave device
check this bit to understand itself if it is a transmitter or a
receiver. The SRW bit is set to ²1² means that the master wants to read data from the I2C Bus, so the slave device must write data to a bus as a transmitter. The SRW
is cleared to ²0² means that the master wants to write
data to the I2C Bus, so the slave device must read data
from the I2C Bus as a receiver.
S D A
Start Bit
Slave Address
The master must select a device for transferring the
data by sending the slave device address after the
START signal. All device in the I2C Bus will receive the
I2C Bus slave address (7 bits) to compare with its own
slave address (7 bits). If the slave address is matched,
the slave device will generate an interrupt and save the
following bit (8th bit) to SRW bit and sends an acknowledge bit (low level) to the 9th bit. The slave device also
sets the status flag (HAAS), when the slave address is
matched.
Rev. 1.21
26
December 29, 2008
HT46RU22
master sends a STOP signal to release the I2C Bus. The
data is stored in the HDR register. The transmitter must
write data to the HDR before transmit data and the receiver must read data from the HDR after receiving
data.
Acknowledge Bit
One of the slave device generates an acknowledge signal, when the slave address is matched. The master device can check this acknowledge bit to know if the slave
device accepts the calling address. If no acknowledge
bit, the master must send a STOP bit and end the communication. When the I2C Bus status register bit 6
HAAS is high, it means the address is matched, so the
slave must check SRW as a transmitter (set HTX) to ²1²
or as a receiver (clear HTX) to ²0².
S C L
S D A
S ta r t b it
S C L
S to p b it
D a ta
s ta b le
D a ta
a llo w
c h a n g e
Data Timing Diagram
S D A
Receive Acknowledge Bit
When the receiver wants to continue to receive the next
data byte, it generates an acknowledge bit (TXAK) at
the 9th clock. The transmitter checks the acknowledge
bit (RXAK) to continue to write data to the I2C Bus or
change to receive mode and dummy read the HDR register to release the SDA line and the master sends the
STOP signal.
Stop Bit
Data Byte
The data is 8 bits and is sent after the slave device has
acknowledges the slave address. The first bit is MSB
and the 8th bit is LSB. The receiver sends the acknowledge signal (²0²) and continues to receive the next 1
byte data. If the transmitter checks and there¢s no acknowledge signal, then it release the SDA line, and the
Rev. 1.21
27
December 29, 2008
HT46RU22
which can also be used as a general purpose I/O pin,
if the pin is not configured as a receiver, which occurs
if the RXEN bit in the UCR2 register is equal to zero.
Along with the UARTEN bit, the TXEN and RXEN bits,
if set, will automatically setup these I/O pins to their respective TX output and RX input conditions and disable any pull-high resistor option which may exist on
the RX pin.
UART Bus Serial Interface
The HT46RU22 devices contain an integrated full-duplex asynchronous serial communications UART interface that enables communication with external devices
that contain a serial interface. The UART function has
many features and can transmit and receive data serially by transferring a frame of data with eight or nine
data bits per transmission as well as being able to detect
errors when the data is overwritten or incorrectly
framed. The UART function possesses its own internal
interrupt which can be used to indicate when a reception
occurs or when a transmission terminates.
· UART data transfer scheme
The block diagram shows the overall data transfer
structure arrangement for the UART. The actual data
to be transmitted from the MCU is first transferred to
the TXR register by the application program. The data
will then be transferred to the Transmit Shift Register
from where it will be shifted out, LSB first, onto the TX
pin at a rate controlled by the Baud Rate Generator.
Only the TXR register is mapped onto the MCU Data
Memory, the Transmit Shift Register is not mapped
and is therefore inaccessible to the application program.
Data to be received by the UART is accepted on the
external RX pin, from where it is shifted in, LSB first, to
the Receiver Shift Register at a rate controlled by the
Baud Rate Generator. When the shift register is full,
the data will then be transferred from the shift register
to the internal RXR register, where it is buffered and
can be manipulated by the application program. Only
the RXR register is mapped onto the MCU Data Memory, the Receiver Shift Register is not mapped and is
therefore inaccessible to the application program.
It should be noted that the actual register for data
transmission and reception, although referred to in the
text, and in application programs, as separate TXR
and RXR registers, only exists as a single shared register in the Data Memory. This shared register known
as the TXR/RXR register is used for both data transmission and data reception.
· UART features
The integrated UART function contains the following
features:
¨
Full-duplex, asynchronous communication
¨
8 or 9 bits character length
¨
Even, odd or no parity options
¨
One or two stop bits
¨
Baud rate generator with 8-bit prescaler
¨
Parity, framing, noise and overrun error detection
¨
Support for interrupt on address detect
(last character bit=1)
¨
Separately enabled transmitter and receiver
¨
2-byte Deep Fifo Receive Data Buffer
¨
Transmit and receive interrupts
¨
Interrupts can be initialized by the following
conditions:
-
Transmitter Empty
-
Transmitter Idle
-
Receiver Full
-
Receiver Overrun
-
Address Mode Detect
· UART status and control registers
There are five control registers associated with the
UART function. The USR, UCR1 and UCR2 registers
control the overall function of the UART, while the
BRG register controls the Baud rate. The actual data
to be transmitted and received on the serial interface
is managed through the TXR/RXR data registers.
· UART external pin interfacing
To communicate with an external serial interface, the
internal UART has two external pins known as TX and
RX. The TX pin is the UART transmitter pin, which can
be used as a general purpose I/O pin if the pin is not
configured as a UART transmitter, which occurs when
the TXEN bit in the UCR2 control register is equal to
zero. Similarly, the RX pin is the UART receiver pin,
T r a n s m itte r S h ift R e g is te r
M S B
R e c e iv e r S h ift R e g is te r
L S B
T X P in
C L K
T X R
R e g is te r
M S B
R X P in
L S B
C L K
B a u d R a te
G e n e ra to r
M C U
R X R
R e g is te r
B u ffe r
D a ta B u s
UART Data Transfer Scheme
Rev. 1.21
28
December 29, 2008
HT46RU22
· USR register
RXIF flag is cleared when the USR register is read
with RXIF set, followed by a read from the RXR register, and if the RXR register has no data available.
The USR register is the status register for the UART,
which can be read by the program to determine the
present status of the UART. All flags within the USR
register are read only.
Further explanation on each of the flags is given below:
¨
¨
¨
TXIF
The TXIF flag is the transmit data register empty
flag. When this read only flag is ²0² it indicates that
the character is not transferred to the transmit shift
registers. When the flag is ²1² it indicates that the
transmit shift register has received a character from
the TXR data register. The TXIF flag is cleared by
reading the UART status register (USR) with TXIF
set and then writing to the TXR data register. Note
that when the TXEN bit is set, the TXIF flag bit will
also be set since the transmit buffer is not yet full.
TIDLE
The TIDLE flag is known as the transmission complete flag. When this read only flag is ²0² it indicates
that a transmission is in progress. This flag will be
set to ²1² when the TXIF flag is ²1² and when there
is no transmit data, or break character being transmitted. When TIDLE is ²1² the TX pin becomes idle.
The TIDLE flag is cleared by reading the USR register with TIDLE set and then writing to the TXR register. The flag is not generated when a data character,
or a break is queued and ready to be sent.
RXIF
The RXIF flag is the receive register status flag.
When this read only flag is ²0² it indicates that the
RXR read data register is empty. When the flag is
²1² it indicates that the RXR read data register contains new data. When the contents of the shift register are transferred to the RXR register, an interrupt
is generated if RIE=1 in the UCR2 register. If one or
more errors are detected in the received word, the
appropriate receive-related flags NF, FERR, and/or
PERR are set within the same clock cycle. The
b 7
P E R R
¨
RIDLE
The RIDLE flag is the receiver status flag. When this
read only flag is ²0² it indicates that the receiver is
between the initial detection of the start bit and the
completion of the stop bit. When the flag is ²1² it indicates that the receiver is idle. Between the completion of the stop bit and the detection of the next
start bit, the RIDLE bit is ²1² indicating that the
UART is idle.
¨
OERR
The OERR flag is the overrun error flag, which indicates when the receiver buffer has overflowed.
When this read only flag is ²0² there is no overrun error. When the flag is ²1² an overrun error occurs
which will inhibit further transfers to the RXR receive
data register. The flag is cleared by a software sequence, which is a read to the status register USR
followed by an access to the RXR data register.
¨
FERR
The FERR flag is the framing error flag. When this
read only flag is ²0² it indicates no framing error.
When the flag is ²1² it indicates that a framing error
has been detected for the current character. The
flag can also be cleared by a software sequence
which will involve a read to the USR status register
followed by an access to the RXR data register.
¨
NF
The NF flag is the noise flag. When this read only
flag is ²0² it indicates a no noise condition. When
the flag is ²1² it indicates that the UART has detected noise on the receiver input. The NF flag is set
during the same cycle as the RXIF flag but will not
be set in the case of an overrun. The NF flag can be
cleared by a software sequence which will involve a
read to the USR status register, followed by an access to the RXR data register.
b 0
N F
F E R R
O E R R
R ID L E
R X IF
T ID L E
T X IF
U S R
R e g is te r
T r a n s m it d a ta r e g is te r e m p ty
1 : c h a r a c te r tr a n s fe r r e d to tr a n s m it s h ift r e g is te r
0 : c h a r a c te r n o t tr a n s fe r r e d to tr a n s m it s h ift r e g is te r
T r a n s m is s io n id le
1 : n o tr a n s m is s io n in p r o g r e s s
0 : tr a n s m is s io n in p r o g r e s s
R e c e iv e R X R r e g is te r s ta tu s
1 : R X R r e g is te r h a s a v a ila b le d a ta
0 : R X R r e g is te r is e m p ty
R e c e iv e r s ta tu s
1 : r e c e iv e r is id le
0 : d a ta b e in g r e c e iv e d
O v e rru n e rro r
1 : o v e rru n e rro r d e te c te d
0 : n o o v e rru n e rro r d e te c te d
F r a m in g e r r o r fla g
1 : fr a m in g e r r o r d e te c te d
0 : n o fr a m in g e r r o r
N o is e fla g
1 : n o is e d e te c te d
0 : n o n o is e d e te c te d
P a r ity e r r o r fla g
1 : p a r ity e r r o r d e te c te d
0 : n o p a r ity e r r o r d e te c te d
Rev. 1.21
29
December 29, 2008
HT46RU22
¨
used, if the bit is equal to ²0² then only one stop bit is
used.
PERR
The PERR flag is the parity error flag. When this
read only flag is ²0² it indicates that a parity error
has not been detected. When the flag is ²1² it indicates that the parity of the received word is incorrect. This error flag is applicable only if Parity mode
(odd or even) is selected. The flag can also be
cleared by a software sequence which involves a
read to the USR status register, followed by an access to the RXR data register.
· UCR1 register
The UCR1 register together with the UCR2 register
are the two UART control registers that are used to set
the various options for the UART function, such as
overall on/off control, parity control, data transfer bit
length etc.
Further explanation on each of the bits is given below:
¨
TX8
This bit is only used if 9-bit data transfers are used,
in which case this bit location will store the 9th bit of
the transmitted data, known as TX8. The BNO bit is
used to determine whether data transfers are in
8-bit or 9-bit format.
¨
RX8
This bit is only used if 9-bit data transfers are used,
in which case this bit location will store the 9th bit of
the received data, known as RX8. The BNO bit is
used to determine whether data transfers are in
8-bit or 9-bit format.
¨
TXBRK
The TXBRK bit is the Transmit Break Character bit.
When this bit is ²0² there are no break characters
and the TX pin operates normally. When the bit is
²1² there are transmit break characters and the
transmitter will send logic zeros. When equal to ²1²
after the buffered data has been transmitted, the
transmitter output is held low for a minimum of a
13-bit length and until the TXBRK bit is reset.
¨
STOPS
This bit determines if one or two stop bits are to be
used. When this bit is equal to ²1² two stop bits are
b 7
U A R T E N
¨
PRT
This is the parity type selection bit. When this bit is
equal to ²1² odd parity will be selected, if the bit is
equal to ²0² then even parity will be selected.
¨
PREN
This is parity enable bit. When this bit is equal to ²1²
the parity function will be enabled, if the bit is equal
to ²0² then the parity function will be disabled.
¨
BNO
This bit is used to select the data length format,
which can have a choice of either 8-bits or 9-bits. If
this bit is equal to ²1² then a 9-bit data length will be
selected, if the bit is equal to ²0² then an 8-bit data
length will be selected. If 9-bit data length is selected then bits RX8 and TX8 will be used to store
the 9th bit of the received and transmitted data respectively.
¨
UARTEN
The UARTEN bit is the UART enable bit. When the
bit is ²0² the UART will be disabled and the RX and
TX pins will function as General Purpose I/O pins.
When the bit is ²1² the UART will be enabled and
the TX and RX pins will function as defined by the
TXEN and RXEN control bits. When the UART is
disabled it will empty the buffer so any character remaining in the buffer will be discarded. In addition,
the baud rate counter value will be reset. When the
UART is disabled, all error and status flags will be
reset. The TXEN, RXEN, TXBRK, RXIF, OERR,
FERR, PERR, and NF bits will be cleared, while the
TIDLE, TXIF and RIDLE bits will be set. Other control bits in UCR1, UCR2, and BRG registers will remain unaffected. If the UART is active and the
UARTEN bit is cleared, all pending transmissions
and receptions will be terminated and the module
will be reset as defined above. When the UART is
re-enabled it will restart in the same configuration.
b 0
B N O
P R E N
P R T
S T O P S
T X B R K
R X 8
T X 8
U C R 1 R e g is te r
T r a n s m it d a ta b it 8 ( w r ite o n ly )
R e c e iv e d a ta b it 8 ( r e a d o n ly )
T r a n s m it b r e a k c h a r a c te r
1 : tr a n s m it b r e a k c h a r a c te r s
0 : n o b re a k c h a ra c te rs
D e fin e s th e n u m b e r o f s to p b its
1 : tw o s to p b its
0 : o n e s to p b it
P a r ity ty p e b it
1 : o d d p a r ity fo r p a r ity g e n e r a to r
0 : e v e n p a r ity fo r p a r ity g e n e r a to r
P a r ity e n a b le b it
1 : p a r ity fu n c tio n e n a b le d
0 : p a r ity fu n c tio n d is a b le d
N u m b e r o f d a ta tr a n s fe r b its
1 : 9 - b it d a ta tr a n s fe r
0 : 8 - b it d a ta tr a n s fe r
U A R T e n a b le b it
1 : e n a b le U A R T , T X & R X p in s a s U A R T p in s
0 : d is a b le U A R T , T X & R X p in s a s I/O p o r t p in s
Rev. 1.21
30
December 29, 2008
HT46RU22
· UCR2 register
to ²0² and if the MCU is in the Power Down Mode,
any edge transitions on the RX pin will not wake-up
the device.
The UCR2 register is the second of the two UART
control registers and serves several purposes. One of
its main functions is to control the basic enable/disable operation of the UART Transmitter and Receiver
as well as enabling the various UART interrupt
sources. The register also serves to control the baud
rate speed, receiver wake-up enable and the address
detect enable.
Further explanation on each of the bits is given below:
¨
ADDEN
The ADDEN bit is the address detect mode bit.
When this bit is ²1² the address detect mode is enabled. When this occurs, if the 8th bit, which corresponds to RX7 if BNO=0, or the 9th bit, which
corresponds to RX8 if BNO=1, has a value of ²1²
then the received word will be identified as an address, rather than data. If the corresponding interrupt is enabled, an interrupt request will be
generated each time the received word has the address bit set, which is the 8 or 9 bit depending on the
value of BNO. If the address bit is ²0² an interrupt
will not be generated, and the received data will be
discarded.
¨
TEIE
This bit enables or disables the transmitter empty
interrupt. If this bit is equal to ²1² when the transmitter empty TXIF flag is set, due to a transmitter
empty condition, the UART interrupt request flag
will be set. If this bit is equal to ²0² the UART interrupt request flag will not be influenced by the condition of the TXIF flag.
¨
¨
TIIE
This bit enables or disables the transmitter idle interrupt. If this bit is equal to ²1² when the transmitter
idle TIDLE flag is set, the UART interrupt request
flag will be set. If this bit is equal to ²0² the UART interrupt request flag will not be influenced by the
condition of the TIDLE flag.
BRGH
The BRGH bit selects the high or low speed mode
of the Baud Rate Generator. This bit, together with
the value placed in the BRG register, controls the
Baud Rate of the UART. If this bit is equal to ²1² the
high speed mode is selected. If the bit is equal to ²0²
the low speed mode is selected.
¨
¨
RIE
This bit enables or disables the receiver interrupt. If
this bit is equal to ²1² when the receiver overrun
OERR flag or receive data available RXIF flag is
set, the UART interrupt request flag will be set. If
this bit is equal to ²0² the UART interrupt will not be
influenced by the condition of the OERR or RXIF
flags.
¨
WAKE
This bit enables or disables the receiver wake-up
function. If this bit is equal to ²1² and if the MCU is in
the Power Down Mode, a low going edge on the RX
input pin will wake-up the device. If this bit is equal
RXEN
The RXEN bit is the Receiver Enable Bit. When this
bit is equal to ²0² the receiver will be disabled with
any pending data receptions being aborted. In addition the buffer will be reset. In this situation the RX
pin can be used as a general purpose I/O pin. If the
RXEN bit is equal to ²1² the receiver will be enabled
and if the UARTEN bit is equal to ²1² the RX pin will
be controlled by the UART. Clearing the RXEN bit
during a transmission will cause the data reception
to be aborted and will reset the receiver. If this occurs, the RX pin can be used as a general purpose
I/O pin.
b 7
T X E N
b 0
R X E N
B R G H
A D D E N
W A K E
R IE
T IIE
T E IE
U C R 2 R e g is te r
T r a n s m itte r e m p ty in te r r u p t e n a b le
1 : T X IF in te r r u p t r e q u e s t e n a b le
0 : T X IF in te r r u p t r e q u e s t d is a b le
T r a n s m itte r id le in te r r u p t e n a b le
1 : T ID L E in te r r u p t r e q u e s t e n a b le
0 : T ID L E in te r r u p t r e q u e s t d is a b le
R e c e iv e r in te r r u p t e n a b le
1 : R X IF in te r r u p t r e q u e s t e n a b le
0 : R X IF in te r r u p t r e q u e s t d is a b le
D e fin e s th e R X w a k e u p e n a b le
1 : R X w a k e u p e n a b le ( fa llin g e d g e )
0 : R X w a k e u p d is a b le
A d d re s s d e te c t m o d e
1 : e n a b le
0 : d is a b le
H ig h b a u d r a te s e le c t b it
1 : h ig h s p e e d
0 : lo w s p e e d
R e c e iv e r e n a b le b it
1 : r e c e iv e r e n a b le
0 : r e c e iv e r d is a b le
T r a n s m itte r e n a b le b it
1 : tr a n s m itte r e n a b le
0 : tr a n s m itte r d is a b le
Rev. 1.21
31
December 29, 2008
HT46RU22
¨
TXEN
The TXEN bit is the Transmitter Enable Bit. When
this bit is equal to ²0² the transmitter will be disabled
with any pending transmissions being aborted. In
addition the buffer will be reset. In this situation the
TX pin can be used as a general purpose I/O pin. If
the TXEN bit is equal to ²1² the transmitter will be
enabled and if the UARTEN bit is equal to ²1² the
TX pin will be controlled by the UART. Clearing the
TXEN bit during a transmission will cause the transmission to be aborted and will reset the transmitter.
If this occurs, the TX pin can be used as a general
purpose I/O pin.
By programming the BRGH bit which allows selection
of the related formula and programming the required
value in the BRG register, the required baud rate can
be setup. Note that because the actual baud rate is
determined using a discrete value, N, placed in the
BRG register, there will be an error associated between the actual and requested value. The following
example shows how the BRG register value N and the
error value can be calculated.
Calculating the register and error values
For a clock frequency of 8MHz, and with BRGH set to
²0² determine the BRG register value N, the actual
baud rate and the error value for a desired baud rate
of 9600.
From the above table the desired baud rate BR
fSYS
=
[64 (N + 1)]
fSYS
Re-arranging this equation gives N =
-1
(BRx64)
8000000
- 1 = 12.0208
Giving a value for N =
(9600x 64)
· Baud rate generator
To setup the speed of the serial data communication,
the UART function contains its own dedicated baud
rate generator. The baud rate is controlled by its own
internal free running 8-bit timer, the period of which is
determined by two factors. The first of these is the
value placed in the BRG register and the second is the
value of the BRGH bit within the UCR2 control register. The BRGH bit decides, if the baud rate generator
is to be used in a high speed mode or low speed
mode, which in turn determines the formula that is
used to calculate the baud rate. The value in the BRG
register determines the division factor, N, which is
used in the following baud rate calculation formula.
Note that N is the decimal value placed in the BRG
register and has a range of between 0 and 255.
UCR2 BRGH Bit
Baud Rate
0
1
fSYS
[64 (N + 1)]
fSYS
[16 (N + 1)]
To obtain the closest value, a decimal value of 12
should be placed into the BRG register. This gives an
actual or calculated baud rate value of
8000000
BR =
= 9615
[64(12 + 1)]
Therefore the error is equal to = 0.16%
The following tables show actual values of baud rate and error values for the two values of BRGH.
Baud
Rate
K/BPS
Baud Rates for BRGH=0
fSYS=8MHz
fSYS=7.159MHz
fSYS=4MHz
fSYS=3.579545MHz
BRG
Kbaud
Error
BRG
Kbaud
Error
BRG
Kbaud
Error
BRG
Kbaud
Error
0.3
¾
¾
¾
¾
¾
¾
207
0.300
0.00
185
0.300
0.00
1.2
103
1.202
0.16
92
1.203
0.23
51
1.202
0.16
46
1.19
-0.83
2.4
51
2.404
0.16
46
2.38
-0.83
25
2.404
0.16
22
2.432
1.32
4.8
25
4.807
0.16
22
4.863
1.32
12
4.808
0.16
11
4.661
-2.9
9.6
12
9.615
0.16
11
9.322
-2.9
6
8.929
-6.99
5
9.321
-2.9
19.2
6
17.857
-6.99
5
18.64
-2.9
2
20.83
8.51
2
18.643
-2.9
38.4
2
41.667
8.51
2
37.29
-2.9
1
¾
¾
1
¾
¾
57.6
1
62.5
8.51
1
55.93
-2.9
0
62.5
8.51
0
55.93
-2.9
115.2
0
125
8.51
0
111.86
-2.9
¾
¾
¾
¾
¾
¾
Baud Rates and Error Values for BRGH = 0
Rev. 1.21
32
December 29, 2008
HT46RU22
Baud
Rate
K/BPS
Baud Rates for BRGH=1
fSYS=8MHz
fSYS=7.159MHz
fSYS=4MHz
fSYS=3.579545MHz
BRG
Kbaud
Error
BRG
Kbaud
Error
BRG
Kbaud
Error
BRG
Kbaud
Error
0.3
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
¾
1.2
¾
¾
¾
¾
¾
¾
207
1.202
0.16
185
1.203
0.23
2.4
207
2.404
0.16
185
2.405
0.23
103
2.404
0.16
92
2.406
0.23
4.8
103
4.808
0.16
92
4.811
0.23
51
4.808
0.16
46
4.76
-0.83
9.6
51
9.615
0.16
46
9.520
-0.832
25
9.615
0.16
22
9.727
1.32
19.2
25
19.231
0.16
22
19.454
1.32
12
19.231
0.16
11
18.643
-2.9
38.4
12
38.462
0.16
11
37.287
-2.9
6
35.714
-6.99
5
37.286
-2.9
57.6
8
55.556
-3.55
7
55.93
-2.9
3
62.5
8.51
3
55.930
-2.9
115.2
3
125
8.51
3
111.86
-2.9
1
125
8.51
1
111.86
-2.9
250
1
250
0
¾
¾
¾
0
250
0
¾
¾
¾
Baud Rates and Error Values for BRGH = 1
· Setting up and controlling the UART
¨
¨
Clearing the UARTEN bit will disable the TX and RX
pins and allow these two pins to be used as normal
I/O pins. When the UART function is disabled the
buffer will be reset to an empty condition, at the
same time discarding any remaining residual data.
Disabling the UART will also reset the error and status flags with bits TXEN, RXEN, TXBRK, RXIF,
OERR, FERR, PERR and NF being cleared while
bits TIDLE, TXIF and RIDLE will be set. The remaining control bits in the UCR1, UCR2 and BRG
registers will remain unaffected. If the UARTEN bit
in the UCR1 register is cleared while the UART is
active, then all pending transmissions and receptions will be immediately suspended and the UART
will be reset to a condition as defined above. If the
UART is then subsequently re-enabled, it will restart
again in the same configuration.
Introduction
For data transfer, the UART function utilizes a
non-return-to-zero, more commonly known as
NRZ, format. This is composed of one start bit, eight
or nine data bits, and one or two stop bits. Parity is
supported by the UART hardware, and can be
setup to be even, odd or no parity. For the most
common data format, 8 data bits along with no parity and one stop bit, denoted as 8, N, 1, is used as
the default setting, which is the setting at power-on.
The number of data bits and stop bits, along with the
parity, are setup by programming the corresponding
BNO, PRT, PREN, and STOPS bits in the UCR1
register. The baud rate used to transmit and receive
data is setup using the internal 8-bit baud rate generator, while the data is transmitted and received
LSB first. Although the UART¢s transmitter and receiver are functionally independent, they both use
the same data format and baud rate. In all cases
stop bits will be used for data transmission.
¨
Enabling/disabling the UART
The basic on/off function of the internal UART function is controlled using the UARTEN bit in the UCR1
register. As the UART transmit and receive pins, TX
and RX respectively, are pin-shared with normal I/O
pins, one of the basic functions of the UARTEN control bit is to control the UART function of these two
pins. If the UARTEN, TXEN and RXEN bits are set,
then these two I/O pins will be setup as a TX output
pin and an RX input pin respectively, in effect disabling the normal I/O pin function. If no data is being
transmitted on the TX pin then it will default to a
logic high value.
Rev. 1.21
33
Data, parity and stop bit selection
The format of the data to be transferred, is composed of various factors such as data bit length,
parity on/off, parity type, address bits and the number of stop bits. These factors are determined by
the setup of various bits within the UCR1 register.
The BNO bit controls the number of data bits which
can be set to either 8 or 9, the PRT bit controls the
choice of odd or even parity, the PREN bit controls
the parity on/off function and the STOPS bit decides
whether one or two stop bits are to be used. The following table shows various formats for data transmission. The address bit identifies the frame as an
address character. The number of stop bits, which
can be either one or two, is independent of the data
length.
December 29, 2008
HT46RU22
Start
Bit
Data
Bits
Address
Bits
Parity
Bits
Stop
Bit
¨
Example of 8-bit Data Formats
1
8
0
0
1
1
7
0
1
1
7
1
0
1
1
1
Example of 9-bit Data Formats
1
9
0
0
1
1
8
0
1
1
1
8
11
0
1
Transmitting data
When the UART is transmitting data, the data is
shifted on the TX pin from the shift register, with the
least significant bit first. In the transmit mode, the
TXR register forms a buffer between the internal
bus and the transmitter shift register. It should be
noted that if 9-bit data format has been selected,
then the MSB will be taken from the TX8 bit in the
UCR1 register. The steps to initiate a data transfer
can be summarized as follows:
-
Make the correct selection of the BNO, PRT,
PREN and STOPS bits to define the required
word length, parity type and number of stop bits.
-
Setup the BRG register to select the desired baud
rate.
-
Set the TXEN bit to ensure that the TX pin is used
as a UART transmitter pin and not as an I/O pin.
-
Access the USR register and write the data that is
to be transmitted into the TXR register. Note that
this step will clear the TXIF bit.
-
This sequence of events can now be repeated to
send additional data.
Transmitter Receiver Data Format
The following diagram shows the transmit and receive
waveforms for both 8-bit and 9-bit data formats.
· UART transmitter
Data word lengths of either 8 or 9 bits, can be selected
by programming the BNO bit in the UCR1 register.
When BNO bit is set, the word length will be set to 9
bits. In this case the 9th bit, which is the MSB, needs
to be stored in the TX8 bit in the UCR1 register. At the
transmitter core lies the Transmitter Shift Register,
more commonly known as the TSR, whose data is obtained from the transmit data register, which is known
as the TXR register. The data to be transmitted is
loaded into this TXR register by the application program. The TSR register is not written to with new data
until the stop bit from the previous transmission has
been sent out. As soon as this stop bit has been transmitted, the TSR can then be loaded with new data
from the TXR register, if it is available. It should be
noted that the TSR register, unlike many other registers, is not directly mapped into the Data Memory area
and as such is not available to the application program
for direct read/write operations. An actual transmission of data will normally be enabled when the TXEN
bit is set, but the data will not be transmitted until the
TXR register has been loaded with data and the baud
rate generator has defined a shift clock source. However, the transmission can also be initiated by first
loading data into the TXR register, after which the
TXEN bit can be set. When a transmission of data begins, the TSR is normally empty, in which case a
transfer to the TXR register will result in an immediate
transfer to the TSR. If during a transmission the TXEN
bit is cleared, the transmission will immediately cease
and the transmitter will be reset. The TX output pin will
then return to having a normal general purpose I/O pin
function.
It should be noted that when TXIF=0, data will be inhibited from being written to the TXR register. Clearing the TXIF flag is always achieved using the
following software sequence:
1. A USR register access
2. A TXR register write execution
The read-only TXIF flag is set by the UART hardware and if set indicates that the TXR register is
empty and that other data can now be written into
the TXR register without overwriting the previous
data. If the TEIE bit is set then the TXIF flag will generate an interrupt.
During a data transmission, a write instruction to the
TXR register will place the data into the TXR register, which will be copied to the shift register at the
end of the present transmission. When there is no
data transmission in progress, a write instruction to
the TXR register will place the data directly into the
shift register, resulting in the commencement of
data transmission, and the TXIF bit being immediately set. When a frame transmission is complete,
which happens after stop bits are sent or after the
break frame, the TIDLE bit will be set. To clear the
TIDLE bit the following software sequence is used:
1. A USR register access
2. A TXR register write execution
Note that both the TXIF and TIDLE bits are cleared
by the same software sequence.
P a r ity B it
S ta r t B it
B it 0
B it 1
B it 2
B it 3
B it 4
B it 5
B it 6
B it 7
S to p B it
N e x t
S ta rt
B it
8 -B it D a ta F o r m a t
P a r ity B it
S ta r t B it
B it 0
B it 1
B it 2
B it 3
B it 4
B it 5
B it 6
B it 7
B it 8
S to p B it
N e x t
S ta rt
B it
9 -B it D a ta F o r m a t
Rev. 1.21
34
December 29, 2008
HT46RU22
¨
-
Transmit break
If the TXBRK bit is set then break characters will be
sent on the next transmission. Break character
transmission consists of a start bit, followed by 13´
N ¢0¢ bits and stop bits, where N=1, 2, etc. If a break
character is to be transmitted then the TXBRK bit
must be first set by the application program, then
cleared to generate the stop bits. Transmitting a
break character will not generate a transmit interrupt. Note that a break condition length is at least 13
bits long. If the TXBRK bit is continually kept at a
logic high level then the transmitter circuitry will
transmit continuous break characters. After the application program has cleared the TXBRK bit, the
transmitter will finish transmitting the last break
character and subsequently send out one or two
stop bits. The automatic logic highs at the end of the
last break character will ensure that the start bit of
the next frame is recognized.
At this point the receiver will be enabled which will
begin to look for a start bit.
When a character is received the following sequence of events will occur:
Introduction
The UART is capable of receiving word lengths of either 8 or 9 bits. If the BNO bit is set, the word length
will be set to 9 bits with the MSB being stored in the
RX8 bit of the UCR1 register. At the receiver core lies
the Receive Serial Shift Register, commonly known
as the RSR. The data which is received on the RX
external input pin, is sent to the data recovery block.
The data recovery block operating speed is 16 times
that of the baud rate, while the main receive serial
shifter operates at the baud rate. After the RX pin is
sampled for the stop bit, the received data in RSR is
transferred to the receive data register, if the register
is empty. The data which is received on the external
RX input pin is sampled three times by a majority detect circuit to determine the logic level that has been
placed onto the RX pin. It should be noted that the
RSR register, unlike many other registers, is not directly mapped into the Data Memory area and as
such is not available to the application program for
direct read/write operations.
¨
Receiving data
When the UART receiver is receiving data, the data
is serially shifted in on the external RX input pin,
LSB first. In the read mode, the RXR register forms
a buffer between the internal bus and the receiver
shift register. The RXR register is a two byte deep
FIFO data buffer, where two bytes can be held in the
FIFO while a third byte can continue to be received.
Note that the application program must ensure that
the data is read from RXR before the third byte has
been completely shifted in, otherwise this third byte
will be discarded and an overrun error OERR will be
subsequently indicated. The steps to initiate a data
transfer can be summarized as follows:
-
Make the correct selection of BNO, PRT, PREN
and STOPS bits to define the word length, parity
type and number of stop bits.
-
Setup the BRG register to select the desired baud
rate.
Rev. 1.21
-
The RXIF bit in the USR register will be set when
RXR register has data available, at least one
more character can be read.
-
When the contents of the shift register have been
transferred to the RXR register, then if the RIE bit
is set, an interrupt will be generated.
-
If during reception, a frame error, noise error, parity error, or an overrun error has been detected,
then the error flags can be set.
The RXIF bit can be cleared using the following
software sequence:
1. A USR register access
2. An RXR register read execution
· UART receiver
¨
Set the RXEN bit to ensure that the RX pin is used
as a UART receiver pin and not as an I/O pin.
¨
¨
35
Receive break
Any break character received by the UART will be
managed as a framing error. The receiver will count
and expect a certain number of bit times as specified by the values programmed into the BNO and
STOPS bits. If the break is much longer than 13 bit
times, the reception will be considered as complete
after the number of bit times specified by BNO and
STOPS. The RXIF bit is set, FERR is set, zeros are
loaded into the receive data register, interrupts are
generated if appropriate and the RIDLE bit is set. If
a long break signal has been detected and the receiver has received a start bit, the data bits and the
invalid stop bit, which sets the FERR flag, the receiver must wait for a valid stop bit before looking
for the next start bit. The receiver will not make the
assumption that the break condition on the line is
the next start bit. A break is regarded as a character
that contains only zeros with the FERR flag set. The
break character will be loaded into the buffer and no
further data will be received until stop bits are received. It should be noted that the RIDLE read only
flag will go high when the stop bits have not yet
been received. The reception of a break character
on the UART registers will result in the following:
-
The framing error flag, FERR, will be set.
-
The receive data register, RXR, will be cleared.
-
The OERR, NF, PERR, RIDLE or RXIF flags will
possibly be set.
Idle status
When the receiver is reading data, which means it
will be in between the detection of a start bit and the
reading of a stop bit, the receiver status flag in the
USR register, otherwise known as the RIDLE flag,
will have a zero value. In between the reception of a
stop bit and the detection of the next start bit, the
RIDLE flag will have a high value, which indicates
the receiver is in an idle condition.
December 29, 2008
HT46RU22
¨
-
Receiver interrupt
The read only receive interrupt flag RXIF in the USR
register is set by an edge generated by the receiver.
An interrupt is generated if RIE=1, when a word is
transferred from the Receive Shift Register, RSR, to
the Receive Data Register, RXR. An overrun error
can also generate an interrupt if RIE=1.
No interrupt will be generated. However this bit
rises at the same time as the RXIF bit which itself
generates an interrupt.
Note that the NF flag is reset by a USR register read
operation followed by an RXR register read
operation.
¨
Framing Error - FERR Flag
The read only framing error flag, FERR, in the USR
register, is set if a zero is detected instead of stop
bits. If two stop bits are selected, both stop bits must
be high, otherwise the FERR flag will be set. The
FERR flag is buffered along with the received data
and is cleared on any reset.
¨
Parity Error - PERR Flag
The read only parity error flag, PERR, in the USR
register, is set if the parity of the received word is incorrect. This error flag is only applicable if the parity
is enabled, PREN = 1, and if the parity type, odd or
even is selected. The read only PERR flag is buffered along with the received data bytes. It is
cleared on any reset. It should be noted that the
FERR and PERR flags are buffered along with the
corresponding word and should be read before
reading the data word.
· Managing receiver errors
Several types of reception errors can occur within the
UART module, the following section describes the
various types and how they are managed by the
UART.
¨
Overrun Error - OERR flag
The RXR register is composed of a two byte deep
FIFO data buffer, where two bytes can be held in the
FIFO register, while a third byte can continue to be
received. Before this third byte has been entirely
shifted in, the data should be read from the RXR
register. If this is not done, the overrun error flag
OERR will be consequently indicated.
In the event of an overrun error occurring, the following will happen:
-
The OERR flag in the USR register will be set.
-
The RXR contents will not be lost.
-
The shift register will be overwritten.
· UART interrupt scheme
The UART internal function possesses its own internal interrupt and independent interrupt vector. Several
individual UART conditions can generate an internal
UART interrupt. These conditions are, a transmitter
data register empty, transmitter idle, receiver data
available, receiver overrun, address detect and an RX
pin wake-up. When any of these conditions are created, if the UART interrupt is enabled and the stack is
not full, the program will jump to the UART interrupt
vector where it can be serviced before returning to the
main program. Four of these conditions, have a corresponding USR register flag, which will generate a
UART interrupt if its associated interrupt enable flag in
-
An interrupt will be generated if the RIE bit is set.
The OERR flag can be cleared by an access to the
USR register followed by a read to the RXR register.
¨
Noise Error - NF Flag
Over-sampling is used for data recovery to identify
valid incoming data and noise. If noise is detected
within a frame the following will occur:
-
The read only noise flag, NF, in the USR register
will be set on the rising edge of the RXIF bit.
-
Data will be transferred from the Shift register to
the RXR register.
U S R R e g is te r
U C R 2 R e g is te r
0
T E IE
T r a n s m itte r E m p ty
F la g T X IF
1
IN T C 1
R e g is te r
U A R T In te rru p t
R e q u e s t F la g
U R F
0
T IIE
T r a n s m itte r Id le
F la g T ID L E
1
R e c e iv e r O v e r r u n
F la g O E R R
R e c e iv e r D a ta
A v a ila b le R X IF
E M I
0
R IE
O R
E U R I
IN T C 0
R e g is te r
1
0
A D D E N
1
0
1
R X P in
W a k e -u p
0
W A K E
R X 7 if B N O = 0
R X 8 if B N O = 1
1
U C R 2 R e g is te r
UART Interrupt Scheme
Rev. 1.21
36
December 29, 2008
HT46RU22
mode is enabled, then to ensure correct operation, the
parity function should be disabled by resetting the parity enable bit to zero.
the UCR2 register is set. The two transmitter interrupt
conditions have their own corresponding enable bits,
while the two receiver interrupt conditions have a
shared enable bit. These enable bits can be used to
mask out individual UART interrupt sources.
The address detect condition, which is also a UART
interrupt source, does not have an associated flag,
but will generate a UART interrupt when an address
detect condition occurs if its function is enabled by
setting the ADDEN bit in the UCR2 register. An RX pin
wake-up, which is also a UART interrupt source, does
not have an associated flag, but will generate a UART
interrupt if the microcontroller is woken up by a low going edge on the RX pin, if the WAKE and RIE bits in
the UCR2 register are set. Note that in the event of an
RX wake-up interrupt occurring, there will be a delay
of 1024 system clock cycles before the system resumes normal operation.
Note that the USR register flags are read only and
cannot be cleared or set by the application program,
neither will they be cleared when the program jumps
to the corresponding interrupt servicing routine, as is
the case for some of the other interrupts. The flags will
be cleared automatically when certain actions are
taken by the UART, the details of which are given in
the UART register section. The overall UART interrupt
can be disabled or enabled by the EURI bit in the
INTC1 interrupt control register to prevent a UART interrupt from occurring.
ADDEN
0
Ö
1
Ö
0
X
1
Ö
0
1
ADDEN Bit Function
· UART operation in power down mode
When the MCU is in the Power Down Mode the UART
will cease to function. When the device enters the
Power Down Mode, all clock sources to the module
are shutdown. If the MCU enters the Power Down
Mode while a transmission is still in progress, then the
transmission will be terminated and the external TX
transmit pin will be forced to a logic high level. In a
similar way, if the MCU enters the Power Down Mode
while receiving data, then the reception of data will
likewise be terminated. When the MCU enters the
Power Down Mode, note that the USR, UCR1, UCR2,
transmit and receive registers, as well as the BRG
register will not be affected.
The UART function contains a receiver RX pin
wake-up function, which is enabled or disabled by the
WAKE bit in the UCR2 register. If this bit, along with
the UART enable bit, UARTEN, the receiver enable
bit, RXEN and the receiver interrupt bit, RIE, are all
set before the MCU enters the Power Down Mode,
then a falling edge on the RX pin will wake-up the
MCU from the Power Down Mode. Note that as it
takes 1024 system clock cycles after a wake-up, before normal microcontroller operation resumes, any
data received during this time on the RX pin will be ignored.
For a UART wake-up interrupt to occur, in addition to
the bits for the wake-up being set, the global interrupt
enable bit, EMI, and the UART interrupt enable bit,
EURI must also be set. If these two bits are not set
then only a wake up event will occur and no interrupt
will be generated. Note also that as it takes 1024 system clock cycles after a wake-up before normal
microcontroller resumes, the UART interrupt will not
be generated until after this time has elapsed.
· Address detect mode
Setting the Address Detect Mode bit, ADDEN, in the
UCR2 register, enables this special mode. If this bit is
enabled then an additional qualifier will be placed on
the generation of a Receiver Data Available interrupt,
which is requested by the RXIF flag. If the ADDEN bit
is enabled, then when data is available, an interrupt
will only be generated, if the highest received bit has a
high value. Note that the EURI and EMI interrupt enable bits must also be enabled for correct interrupt
generation. This highest address bit is the 9th bit if
BNO=1 or the 8th bit if BNO=0. If this bit is high, then
the received word will be defined as an address rather
than data. A Data Available interrupt will be generated
every time the last bit of the received word is set. If the
ADDEN bit is not enabled, then a Receiver Data Available interrupt will be generated each time the RXIF
flag is set, irrespective of the data last bit status. The
address detect mode and parity enable are mutually
exclusive functions. Therefore if the address detect
Rev. 1.21
Bit 9 if BNO=1, UART Interrupt
Bit 8 if BNO=0
Generated
37
December 29, 2008
HT46RU22
Options
The following shows ten kinds of options in the microcontroller. ALL the options must be defined to ensure proper system function.
No.
Options
1
OSC type selection.
This option is to decide if an RC or crystal oscillator is chosen as system clock.
2
WDT source selection.
There are three types of selection: On-chip RC oscillator, instruction clock or disable the WDT.
3
CLRWDT times selection.
This option defines how to clear the WDT by instruction. ²One time² means that the CLR WDT instruction can
clear the WDT. ²Two times² means only if both of the CLR WDT1 and CLR WDT2 instructions have been executed, then WDT can be cleared.
4
Wake-up selection.
This option defines the wake-up function activity. External I/O pins (PA only) all have the capability to wake-up
the chip from a HALT.
5
Pull-high selection.
This option is to decide whether a pull-high resistance is visible or not in the input mode of the I/O ports.
PA0~PA7, can be independently selected.
6
PFD selection.
PA3: Level output or PFD output
7
PWM selection: (7+1) or (6+2) mode
PD0: Level output or PWM output
8
WDT time-out period selection.
212/fS~213/fS, 213/fS~214/fS, 214/fS~215/fS, 215/fS~216/fS.
9
Low voltage reset selection: Enable or disable LVR function.
10
I2C Bus function: Enable or disable
Rev. 1.21
38
December 29, 2008
HT46RU22
Application Circuits
V
D D
V D D
P A 0 ~ P A 2
P A 3 /P F D
R e s e t
C ir c u it
1 0 0 k W
0 .1 m F
P A 4 /T M R
V
D D
P A 5 /IN T
R E S
P A 6 /S D A
V S S
P B 0 /A N 0
P B 7 /A N 7
0 .1 m F
4 7 0 p F
P A 7 /S C L
R
O S C
O S C 1
fS
Y S
/4
R C S y s te m O s c illa to r
3 0 k W < R O S C < 7 5 0 k W
O S C 2
~
C 1
P C 0 /T X
P C 1 /R X
O S C
C ir c u it
O S C 1
O S C 1
C 2
P D 0 /P W M
R 1
O S C 2
H T 4 6 R U 2 2
O S C 2
O S C
C r y s ta l/R e s o n a to r
S y s te m O s c illa to r
F o r R 1 , C 1 , C 2 s e e n o te
C ir c u it
Note: 1. Crystal/resonator system oscillators
For crystal oscillators, C1 and C2 are only required for some crystal frequencies to ensure oscillation. For
resonator applications C1 and C2 are normally required for oscillation to occur. For most applications it is not
necessary to add R1. However if the LVR function is disabled, and if it is required to stop the oscillator when
VDD falls below its operating range, it is recommended that R1 is added. The values of C1 and C2 should be
selected in consultation with the crystal/resonator manufacturer specifications.
2. Reset circuit
The reset circuit resistance and capacitance values should be chosen to ensure that VDD is stable and remains within its operating voltage range before the RES pin reaches a high level. Ensure that the length of
the wiring connected to the RES pin is kept as short as possible, to avoid noise interference.
3. For applications where noise may interfere with the reset circuit and for details on the oscillator external components, refer to Application Note HA0075E for more information.
Rev. 1.21
39
December 29, 2008
HT46RU22
Instruction Set
subtract instruction mnemonics to enable the necessary
arithmetic to be carried out. Care must be taken to ensure correct handling of carry and borrow data when results exceed 255 for addition and less than 0 for
subtraction. The increment and decrement instructions
INC, INCA, DEC and DECA provide a simple means of
increasing or decreasing by a value of one of the values
in the destination specified.
Introduction
Central to the successful operation of any
microcontroller is its instruction set, which is a set of program instruction codes that directs the microcontroller to
perform certain operations. In the case of Holtek
microcontrollers, a comprehensive and flexible set of
over 60 instructions is provided to enable programmers
to implement their application with the minimum of programming overheads.
Logical and Rotate Operations
For easier understanding of the various instruction
codes, they have been subdivided into several functional groupings.
The standard logical operations such as AND, OR, XOR
and CPL all have their own instruction within the Holtek
microcontroller instruction set. As with the case of most
instructions involving data manipulation, data must pass
through the Accumulator which may involve additional
programming steps. In all logical data operations, the
zero flag may be set if the result of the operation is zero.
Another form of logical data manipulation comes from
the rotate instructions such as RR, RL, RRC and RLC
which provide a simple means of rotating one bit right or
left. Different rotate instructions exist depending on program requirements. Rotate instructions are useful for
serial port programming applications where data can be
rotated from an internal register into the Carry bit from
where it can be examined and the necessary serial bit
set high or low. Another application where rotate data
operations are used is to implement multiplication and
division calculations.
Instruction Timing
Most instructions are implemented within one instruction cycle. The exceptions to this are branch, call, or table read instructions where two instruction cycles are
required. One instruction cycle is equal to 4 system
clock cycles, therefore in the case of an 8MHz system
oscillator, most instructions would be implemented
within 0.5ms and branch or call instructions would be implemented within 1ms. Although instructions which require one more cycle to implement are generally limited
to the JMP, CALL, RET, RETI and table read instructions, it is important to realize that any other instructions
which involve manipulation of the Program Counter Low
register or PCL will also take one more cycle to implement. As instructions which change the contents of the
PCL will imply a direct jump to that new address, one
more cycle will be required. Examples of such instructions would be ²CLR PCL² or ²MOV PCL, A². For the
case of skip instructions, it must be noted that if the result of the comparison involves a skip operation then
this will also take one more cycle, if no skip is involved
then only one cycle is required.
Branches and Control Transfer
Program branching takes the form of either jumps to
specified locations using the JMP instruction or to a subroutine using the CALL instruction. They differ in the
sense that in the case of a subroutine call, the program
must return to the instruction immediately when the subroutine has been carried out. This is done by placing a
return instruction RET in the subroutine which will cause
the program to jump back to the address right after the
CALL instruction. In the case of a JMP instruction, the
program simply jumps to the desired location. There is
no requirement to jump back to the original jumping off
point as in the case of the CALL instruction. One special
and extremely useful set of branch instructions are the
conditional branches. Here a decision is first made regarding the condition of a certain data memory or individual bits. Depending upon the conditions, the program
will continue with the next instruction or skip over it and
jump to the following instruction. These instructions are
the key to decision making and branching within the program perhaps determined by the condition of certain input switches or by the condition of internal data bits.
Moving and Transferring Data
The transfer of data within the microcontroller program
is one of the most frequently used operations. Making
use of three kinds of MOV instructions, data can be
transferred from registers to the Accumulator and
vice-versa as well as being able to move specific immediate data directly into the Accumulator. One of the most
important data transfer applications is to receive data
from the input ports and transfer data to the output ports.
Arithmetic Operations
The ability to perform certain arithmetic operations and
data manipulation is a necessary feature of most
microcontroller applications. Within the Holtek
microcontroller instruction set are a range of add and
Rev. 1.21
40
December 29, 2008
HT46RU22
Bit Operations
Other Operations
The ability to provide single bit operations on Data Memory is an extremely flexible feature of all Holtek
microcontrollers. This feature is especially useful for
output port bit programming where individual bits or port
pins can be directly set high or low using either the ²SET
[m].i² or ²CLR [m].i² instructions respectively. The feature removes the need for programmers to first read the
8-bit output port, manipulate the input data to ensure
that other bits are not changed and then output the port
with the correct new data. This read-modify-write process is taken care of automatically when these bit operation instructions are used.
In addition to the above functional instructions, a range
of other instructions also exist such as the ²HALT² instruction for Power-down operations and instructions to
control the operation of the Watchdog Timer for reliable
program operations under extreme electric or electromagnetic environments. For their relevant operations,
refer to the functional related sections.
Instruction Set Summary
The following table depicts a summary of the instruction
set categorised according to function and can be consulted as a basic instruction reference using the following listed conventions.
Table Read Operations
Table conventions:
Data storage is normally implemented by using registers. However, when working with large amounts of
fixed data, the volume involved often makes it inconvenient to store the fixed data in the Data Memory. To overcome this problem, Holtek microcontrollers allow an
area of Program Memory to be setup as a table where
data can be directly stored. A set of easy to use instructions provides the means by which this fixed data can be
referenced and retrieved from the Program Memory.
Mnemonic
x: Bits immediate data
m: Data Memory address
A: Accumulator
i: 0~7 number of bits
addr: Program memory address
Description
Cycles
Flag Affected
1
1Note
1
1
1Note
1
1
1Note
1
1Note
1Note
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
Z, C, AC, OV
C
1
1
1
1Note
1Note
1Note
1
1
1
1Note
1
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
1
1Note
1
1Note
Z
Z
Z
Z
Arithmetic
ADD A,[m]
ADDM A,[m]
ADD A,x
ADC A,[m]
ADCM A,[m]
SUB A,x
SUB A,[m]
SUBM A,[m]
SBC A,[m]
SBCM A,[m]
DAA [m]
Add Data Memory to ACC
Add ACC to Data Memory
Add immediate data to ACC
Add Data Memory to ACC with Carry
Add ACC to Data memory with Carry
Subtract immediate data from the ACC
Subtract Data Memory from ACC
Subtract Data Memory from ACC with result in Data Memory
Subtract Data Memory from ACC with Carry
Subtract Data Memory from ACC with Carry, result in Data Memory
Decimal adjust ACC for Addition with result in Data Memory
Logic Operation
AND A,[m]
OR A,[m]
XOR A,[m]
ANDM A,[m]
ORM A,[m]
XORM A,[m]
AND A,x
OR A,x
XOR A,x
CPL [m]
CPLA [m]
Logical AND Data Memory to ACC
Logical OR Data Memory to ACC
Logical XOR Data Memory to ACC
Logical AND ACC to Data Memory
Logical OR ACC to Data Memory
Logical XOR ACC to Data Memory
Logical AND immediate Data to ACC
Logical OR immediate Data to ACC
Logical XOR immediate Data to ACC
Complement Data Memory
Complement Data Memory with result in ACC
Increment & Decrement
INCA [m]
INC [m]
DECA [m]
DEC [m]
Rev. 1.21
Increment Data Memory with result in ACC
Increment Data Memory
Decrement Data Memory with result in ACC
Decrement Data Memory
41
December 29, 2008
HT46RU22
Mnemonic
Description
Cycles
Flag Affected
Rotate Data Memory right with result in ACC
Rotate Data Memory right
Rotate Data Memory right through Carry with result in ACC
Rotate Data Memory right through Carry
Rotate Data Memory left with result in ACC
Rotate Data Memory left
Rotate Data Memory left through Carry with result in ACC
Rotate Data Memory left through Carry
1
1Note
1
1Note
1
1Note
1
1Note
None
None
C
C
None
None
C
C
Move Data Memory to ACC
Move ACC to Data Memory
Move immediate data to ACC
1
1Note
1
None
None
None
Clear bit of Data Memory
Set bit of Data Memory
1Note
1Note
None
None
Jump unconditionally
Skip if Data Memory is zero
Skip if Data Memory is zero with data movement to ACC
Skip if bit i of Data Memory is zero
Skip if bit i of Data Memory is not zero
Skip if increment Data Memory is zero
Skip if decrement Data Memory is zero
Skip if increment Data Memory is zero with result in ACC
Skip if decrement Data Memory is zero with result in ACC
Subroutine call
Return from subroutine
Return from subroutine and load immediate data to ACC
Return from interrupt
2
1Note
1note
1Note
1Note
1Note
1Note
1Note
1Note
2
2
2
2
None
None
None
None
None
None
None
None
None
None
None
None
None
Read table (current page) to TBLH and Data Memory
Read table (last page) to TBLH and Data Memory
2Note
2Note
None
None
No operation
Clear Data Memory
Set Data Memory
Clear Watchdog Timer
Pre-clear Watchdog Timer
Pre-clear Watchdog Timer
Swap nibbles of Data Memory
Swap nibbles of Data Memory with result in ACC
Enter power down mode
1
1Note
1Note
1
1
1
1Note
1
1
None
None
None
TO, PDF
TO, PDF
TO, PDF
None
None
TO, PDF
Rotate
RRA [m]
RR [m]
RRCA [m]
RRC [m]
RLA [m]
RL [m]
RLCA [m]
RLC [m]
Data Move
MOV A,[m]
MOV [m],A
MOV A,x
Bit Operation
CLR [m].i
SET [m].i
Branch
JMP addr
SZ [m]
SZA [m]
SZ [m].i
SNZ [m].i
SIZ [m]
SDZ [m]
SIZA [m]
SDZA [m]
CALL addr
RET
RET A,x
RETI
Table Read
TABRDC [m]
TABRDL [m]
Miscellaneous
NOP
CLR [m]
SET [m]
CLR WDT
CLR WDT1
CLR WDT2
SWAP [m]
SWAPA [m]
HALT
Note:
1. For skip instructions, if the result of the comparison involves a skip then two cycles are required,
if no skip takes place only one cycle is required.
2. Any instruction which changes the contents of the PCL will also require 2 cycles for execution.
3. For the ²CLR WDT1² and ²CLR WDT2² instructions the TO and PDF flags may be affected by
the execution status. The TO and PDF flags are cleared after both ²CLR WDT1² and
²CLR WDT2² instructions are consecutively executed. Otherwise the TO and PDF flags
remain unchanged.
Rev. 1.21
42
December 29, 2008
HT46RU22
Instruction Definition
ADC A,[m]
Add Data Memory to ACC with Carry
Description
The contents of the specified Data Memory, Accumulator and the carry flag are added. The
result is stored in the Accumulator.
Operation
ACC ¬ ACC + [m] + C
Affected flag(s)
OV, Z, AC, C
ADCM A,[m]
Add ACC to Data Memory with Carry
Description
The contents of the specified Data Memory, Accumulator and the carry flag are added. The
result is stored in the specified Data Memory.
Operation
[m] ¬ ACC + [m] + C
Affected flag(s)
OV, Z, AC, C
ADD A,[m]
Add Data Memory to ACC
Description
The contents of the specified Data Memory and the Accumulator are added. The result is
stored in the Accumulator.
Operation
ACC ¬ ACC + [m]
Affected flag(s)
OV, Z, AC, C
ADD A,x
Add immediate data to ACC
Description
The contents of the Accumulator and the specified immediate data are added. The result is
stored in the Accumulator.
Operation
ACC ¬ ACC + x
Affected flag(s)
OV, Z, AC, C
ADDM A,[m]
Add ACC to Data Memory
Description
The contents of the specified Data Memory and the Accumulator are added. The result is
stored in the specified Data Memory.
Operation
[m] ¬ ACC + [m]
Affected flag(s)
OV, Z, AC, C
AND A,[m]
Logical AND Data Memory to ACC
Description
Data in the Accumulator and the specified Data Memory perform a bitwise logical AND operation. The result is stored in the Accumulator.
Operation
ACC ¬ ACC ²AND² [m]
Affected flag(s)
Z
AND A,x
Logical AND immediate data to ACC
Description
Data in the Accumulator and the specified immediate data perform a bitwise logical AND
operation. The result is stored in the Accumulator.
Operation
ACC ¬ ACC ²AND² x
Affected flag(s)
Z
ANDM A,[m]
Logical AND ACC to Data Memory
Description
Data in the specified Data Memory and the Accumulator perform a bitwise logical AND operation. The result is stored in the Data Memory.
Operation
[m] ¬ ACC ²AND² [m]
Affected flag(s)
Z
Rev. 1.21
43
December 29, 2008
HT46RU22
CALL addr
Subroutine call
Description
Unconditionally calls a subroutine at the specified address. The Program Counter then increments by 1 to obtain the address of the next instruction which is then pushed onto the
stack. The specified address is then loaded and the program continues execution from this
new address. As this instruction requires an additional operation, it is a two cycle instruction.
Operation
Stack ¬ Program Counter + 1
Program Counter ¬ addr
Affected flag(s)
None
CLR [m]
Clear Data Memory
Description
Each bit of the specified Data Memory is cleared to 0.
Operation
[m] ¬ 00H
Affected flag(s)
None
CLR [m].i
Clear bit of Data Memory
Description
Bit i of the specified Data Memory is cleared to 0.
Operation
[m].i ¬ 0
Affected flag(s)
None
CLR WDT
Clear Watchdog Timer
Description
The TO, PDF flags and the WDT are all cleared.
Operation
WDT cleared
TO ¬ 0
PDF ¬ 0
Affected flag(s)
TO, PDF
CLR WDT1
Pre-clear Watchdog Timer
Description
The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunction with CLR WDT2 and must be executed alternately with CLR WDT2 to have effect. Repetitively executing this instruction without alternately executing CLR WDT2 will have no
effect.
Operation
WDT cleared
TO ¬ 0
PDF ¬ 0
Affected flag(s)
TO, PDF
CLR WDT2
Pre-clear Watchdog Timer
Description
The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunction with CLR WDT1 and must be executed alternately with CLR WDT1 to have effect. Repetitively executing this instruction without alternately executing CLR WDT1 will have no
effect.
Operation
WDT cleared
TO ¬ 0
PDF ¬ 0
Affected flag(s)
TO, PDF
Rev. 1.21
44
December 29, 2008
HT46RU22
CPL [m]
Complement Data Memory
Description
Each bit of the specified Data Memory is logically complemented (1¢s complement). Bits
which previously contained a 1 are changed to 0 and vice versa.
Operation
[m] ¬ [m]
Affected flag(s)
Z
CPLA [m]
Complement Data Memory with result in ACC
Description
Each bit of the specified Data Memory is logically complemented (1¢s complement). Bits
which previously contained a 1 are changed to 0 and vice versa. The complemented result
is stored in the Accumulator and the contents of the Data Memory remain unchanged.
Operation
ACC ¬ [m]
Affected flag(s)
Z
DAA [m]
Decimal-Adjust ACC for addition with result in Data Memory
Description
Convert the contents of the Accumulator value to a BCD ( Binary Coded Decimal) value resulting from the previous addition of two BCD variables. If the low nibble is greater than 9 or
if AC flag is set, then a value of 6 will be added to the low nibble. Otherwise the low nibble
remains unchanged. If the high nibble is greater than 9 or if the C flag is set, then a value of
6 will be added to the high nibble. Essentially, the decimal conversion is performed by adding 00H, 06H, 60H or 66H depending on the Accumulator and flag conditions. Only the C
flag may be affected by this instruction which indicates that if the original BCD sum is
greater than 100, it allows multiple precision decimal addition.
Operation
[m] ¬ ACC + 00H or
[m] ¬ ACC + 06H or
[m] ¬ ACC + 60H or
[m] ¬ ACC + 66H
Affected flag(s)
C
DEC [m]
Decrement Data Memory
Description
Data in the specified Data Memory is decremented by 1.
Operation
[m] ¬ [m] - 1
Affected flag(s)
Z
DECA [m]
Decrement Data Memory with result in ACC
Description
Data in the specified Data Memory is decremented by 1. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged.
Operation
ACC ¬ [m] - 1
Affected flag(s)
Z
HALT
Enter power down mode
Description
This instruction stops the program execution and turns off the system clock. The contents
of the Data Memory and registers are retained. The WDT and prescaler are cleared. The
power down flag PDF is set and the WDT time-out flag TO is cleared.
Operation
TO ¬ 0
PDF ¬ 1
Affected flag(s)
TO, PDF
Rev. 1.21
45
December 29, 2008
HT46RU22
INC [m]
Increment Data Memory
Description
Data in the specified Data Memory is incremented by 1.
Operation
[m] ¬ [m] + 1
Affected flag(s)
Z
INCA [m]
Increment Data Memory with result in ACC
Description
Data in the specified Data Memory is incremented by 1. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged.
Operation
ACC ¬ [m] + 1
Affected flag(s)
Z
JMP addr
Jump unconditionally
Description
The contents of the Program Counter are replaced with the specified address. Program
execution then continues from this new address. As this requires the insertion of a dummy
instruction while the new address is loaded, it is a two cycle instruction.
Operation
Program Counter ¬ addr
Affected flag(s)
None
MOV A,[m]
Move Data Memory to ACC
Description
The contents of the specified Data Memory are copied to the Accumulator.
Operation
ACC ¬ [m]
Affected flag(s)
None
MOV A,x
Move immediate data to ACC
Description
The immediate data specified is loaded into the Accumulator.
Operation
ACC ¬ x
Affected flag(s)
None
MOV [m],A
Move ACC to Data Memory
Description
The contents of the Accumulator are copied to the specified Data Memory.
Operation
[m] ¬ ACC
Affected flag(s)
None
NOP
No operation
Description
No operation is performed. Execution continues with the next instruction.
Operation
No operation
Affected flag(s)
None
OR A,[m]
Logical OR Data Memory to ACC
Description
Data in the Accumulator and the specified Data Memory perform a bitwise logical OR operation. The result is stored in the Accumulator.
Operation
ACC ¬ ACC ²OR² [m]
Affected flag(s)
Z
Rev. 1.21
46
December 29, 2008
HT46RU22
OR A,x
Logical OR immediate data to ACC
Description
Data in the Accumulator and the specified immediate data perform a bitwise logical OR operation. The result is stored in the Accumulator.
Operation
ACC ¬ ACC ²OR² x
Affected flag(s)
Z
ORM A,[m]
Logical OR ACC to Data Memory
Description
Data in the specified Data Memory and the Accumulator perform a bitwise logical OR operation. The result is stored in the Data Memory.
Operation
[m] ¬ ACC ²OR² [m]
Affected flag(s)
Z
RET
Return from subroutine
Description
The Program Counter is restored from the stack. Program execution continues at the restored address.
Operation
Program Counter ¬ Stack
Affected flag(s)
None
RET A,x
Return from subroutine and load immediate data to ACC
Description
The Program Counter is restored from the stack and the Accumulator loaded with the
specified immediate data. Program execution continues at the restored address.
Operation
Program Counter ¬ Stack
ACC ¬ x
Affected flag(s)
None
RETI
Return from interrupt
Description
The Program Counter is restored from the stack and the interrupts are re-enabled by setting the EMI bit. EMI is the master interrupt global enable bit. If an interrupt was pending
when the RETI instruction is executed, the pending Interrupt routine will be processed before returning to the main program.
Operation
Program Counter ¬ Stack
EMI ¬ 1
Affected flag(s)
None
RL [m]
Rotate Data Memory left
Description
The contents of the specified Data Memory are rotated left by 1 bit with bit 7 rotated into bit
0.
Operation
[m].(i+1) ¬ [m].i; (i = 0~6)
[m].0 ¬ [m].7
Affected flag(s)
None
RLA [m]
Rotate Data Memory left with result in ACC
Description
The contents of the specified Data Memory are rotated left by 1 bit with bit 7 rotated into bit
0. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged.
Operation
ACC.(i+1) ¬ [m].i; (i = 0~6)
ACC.0 ¬ [m].7
Affected flag(s)
None
Rev. 1.21
47
December 29, 2008
HT46RU22
RLC [m]
Rotate Data Memory left through Carry
Description
The contents of the specified Data Memory and the carry flag are rotated left by 1 bit. Bit 7
replaces the Carry bit and the original carry flag is rotated into bit 0.
Operation
[m].(i+1) ¬ [m].i; (i = 0~6)
[m].0 ¬ C
C ¬ [m].7
Affected flag(s)
C
RLCA [m]
Rotate Data Memory left through Carry with result in ACC
Description
Data in the specified Data Memory and the carry flag are rotated left by 1 bit. Bit 7 replaces
the Carry bit and the original carry flag is rotated into the bit 0. The rotated result is stored in
the Accumulator and the contents of the Data Memory remain unchanged.
Operation
ACC.(i+1) ¬ [m].i; (i = 0~6)
ACC.0 ¬ C
C ¬ [m].7
Affected flag(s)
C
RR [m]
Rotate Data Memory right
Description
The contents of the specified Data Memory are rotated right by 1 bit with bit 0 rotated into
bit 7.
Operation
[m].i ¬ [m].(i+1); (i = 0~6)
[m].7 ¬ [m].0
Affected flag(s)
None
RRA [m]
Rotate Data Memory right with result in ACC
Description
Data in the specified Data Memory and the carry flag are rotated right by 1 bit with bit 0 rotated into bit 7. The rotated result is stored in the Accumulator and the contents of the Data
Memory remain unchanged.
Operation
ACC.i ¬ [m].(i+1); (i = 0~6)
ACC.7 ¬ [m].0
Affected flag(s)
None
RRC [m]
Rotate Data Memory right through Carry
Description
The contents of the specified Data Memory and the carry flag are rotated right by 1 bit. Bit 0
replaces the Carry bit and the original carry flag is rotated into bit 7.
Operation
[m].i ¬ [m].(i+1); (i = 0~6)
[m].7 ¬ C
C ¬ [m].0
Affected flag(s)
C
RRCA [m]
Rotate Data Memory right through Carry with result in ACC
Description
Data in the specified Data Memory and the carry flag are rotated right by 1 bit. Bit 0 replaces the Carry bit and the original carry flag is rotated into bit 7. The rotated result is
stored in the Accumulator and the contents of the Data Memory remain unchanged.
Operation
ACC.i ¬ [m].(i+1); (i = 0~6)
ACC.7 ¬ C
C ¬ [m].0
Affected flag(s)
C
Rev. 1.21
48
December 29, 2008
HT46RU22
SBC A,[m]
Subtract Data Memory from ACC with Carry
Description
The contents of the specified Data Memory and the complement of the carry flag are subtracted from the Accumulator. The result is stored in the Accumulator. Note that if the result
of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or
zero, the C flag will be set to 1.
Operation
ACC ¬ ACC - [m] - C
Affected flag(s)
OV, Z, AC, C
SBCM A,[m]
Subtract Data Memory from ACC with Carry and result in Data Memory
Description
The contents of the specified Data Memory and the complement of the carry flag are subtracted from the Accumulator. The result is stored in the Data Memory. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is
positive or zero, the C flag will be set to 1.
Operation
[m] ¬ ACC - [m] - C
Affected flag(s)
OV, Z, AC, C
SDZ [m]
Skip if decrement Data Memory is 0
Description
The contents of the specified Data Memory are first decremented by 1. If the result is 0 the
following instruction is skipped. As this requires the insertion of a dummy instruction while
the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program
proceeds with the following instruction.
Operation
[m] ¬ [m] - 1
Skip if [m] = 0
Affected flag(s)
None
SDZA [m]
Skip if decrement Data Memory is zero with result in ACC
Description
The contents of the specified Data Memory are first decremented by 1. If the result is 0, the
following instruction is skipped. The result is stored in the Accumulator but the specified
Data Memory contents remain unchanged. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not
0, the program proceeds with the following instruction.
Operation
ACC ¬ [m] - 1
Skip if ACC = 0
Affected flag(s)
None
SET [m]
Set Data Memory
Description
Each bit of the specified Data Memory is set to 1.
Operation
[m] ¬ FFH
Affected flag(s)
None
SET [m].i
Set bit of Data Memory
Description
Bit i of the specified Data Memory is set to 1.
Operation
[m].i ¬ 1
Affected flag(s)
None
Rev. 1.21
49
December 29, 2008
HT46RU22
SIZ [m]
Skip if increment Data Memory is 0
Description
The contents of the specified Data Memory are first incremented by 1. If the result is 0, the
following instruction is skipped. As this requires the insertion of a dummy instruction while
the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program
proceeds with the following instruction.
Operation
[m] ¬ [m] + 1
Skip if [m] = 0
Affected flag(s)
None
SIZA [m]
Skip if increment Data Memory is zero with result in ACC
Description
The contents of the specified Data Memory are first incremented by 1. If the result is 0, the
following instruction is skipped. The result is stored in the Accumulator but the specified
Data Memory contents remain unchanged. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not
0 the program proceeds with the following instruction.
Operation
ACC ¬ [m] + 1
Skip if ACC = 0
Affected flag(s)
None
SNZ [m].i
Skip if bit i of Data Memory is not 0
Description
If bit i of the specified Data Memory is not 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two
cycle instruction. If the result is 0 the program proceeds with the following instruction.
Operation
Skip if [m].i ¹ 0
Affected flag(s)
None
SUB A,[m]
Subtract Data Memory from ACC
Description
The specified Data Memory is subtracted from the contents of the Accumulator. The result
is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will
be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1.
Operation
ACC ¬ ACC - [m]
Affected flag(s)
OV, Z, AC, C
SUBM A,[m]
Subtract Data Memory from ACC with result in Data Memory
Description
The specified Data Memory is subtracted from the contents of the Accumulator. The result
is stored in the Data Memory. Note that if the result of subtraction is negative, the C flag will
be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1.
Operation
[m] ¬ ACC - [m]
Affected flag(s)
OV, Z, AC, C
SUB A,x
Subtract immediate data from ACC
Description
The immediate data specified by the code is subtracted from the contents of the Accumulator. The result is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will
be set to 1.
Operation
ACC ¬ ACC - x
Affected flag(s)
OV, Z, AC, C
Rev. 1.21
50
December 29, 2008
HT46RU22
SWAP [m]
Swap nibbles of Data Memory
Description
The low-order and high-order nibbles of the specified Data Memory are interchanged.
Operation
[m].3~[m].0 « [m].7 ~ [m].4
Affected flag(s)
None
SWAPA [m]
Swap nibbles of Data Memory with result in ACC
Description
The low-order and high-order nibbles of the specified Data Memory are interchanged. The
result is stored in the Accumulator. The contents of the Data Memory remain unchanged.
Operation
ACC.3 ~ ACC.0 ¬ [m].7 ~ [m].4
ACC.7 ~ ACC.4 ¬ [m].3 ~ [m].0
Affected flag(s)
None
SZ [m]
Skip if Data Memory is 0
Description
If the contents of the specified Data Memory is 0, the following instruction is skipped. As
this requires the insertion of a dummy instruction while the next instruction is fetched, it is a
two cycle instruction. If the result is not 0 the program proceeds with the following instruction.
Operation
Skip if [m] = 0
Affected flag(s)
None
SZA [m]
Skip if Data Memory is 0 with data movement to ACC
Description
The contents of the specified Data Memory are copied to the Accumulator. If the value is
zero, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the
program proceeds with the following instruction.
Operation
ACC ¬ [m]
Skip if [m] = 0
Affected flag(s)
None
SZ [m].i
Skip if bit i of Data Memory is 0
Description
If bit i of the specified Data Memory is 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two
cycle instruction. If the result is not 0, the program proceeds with the following instruction.
Operation
Skip if [m].i = 0
Affected flag(s)
None
TABRDC [m]
Read table (current page) to TBLH and Data Memory
Description
The low byte of the program code (current page) addressed by the table pointer (TBLP) is
moved to the specified Data Memory and the high byte moved to TBLH.
Operation
[m] ¬ program code (low byte)
TBLH ¬ program code (high byte)
Affected flag(s)
None
TABRDL [m]
Read table (last page) to TBLH and Data Memory
Description
The low byte of the program code (last page) addressed by the table pointer (TBLP) is
moved to the specified Data Memory and the high byte moved to TBLH.
Operation
[m] ¬ program code (low byte)
TBLH ¬ program code (high byte)
Affected flag(s)
None
Rev. 1.21
51
December 29, 2008
HT46RU22
XOR A,[m]
Logical XOR Data Memory to ACC
Description
Data in the Accumulator and the specified Data Memory perform a bitwise logical XOR operation. The result is stored in the Accumulator.
Operation
ACC ¬ ACC ²XOR² [m]
Affected flag(s)
Z
XORM A,[m]
Logical XOR ACC to Data Memory
Description
Data in the specified Data Memory and the Accumulator perform a bitwise logical XOR operation. The result is stored in the Data Memory.
Operation
[m] ¬ ACC ²XOR² [m]
Affected flag(s)
Z
XOR A,x
Logical XOR immediate data to ACC
Description
Data in the Accumulator and the specified immediate data perform a bitwise logical XOR
operation. The result is stored in the Accumulator.
Operation
ACC ¬ ACC ²XOR² x
Affected flag(s)
Z
Rev. 1.21
52
December 29, 2008
HT46RU22
Package Information
24-pin SKDIP (300mil) Outline Dimensions
A
A
1 3
2 4
B
1 3
2 4
B
1 2
1
1 2
1
H
H
C
C
D
D
E
F
I
G
E
F
I
G
Fig2. 1/2 Lead Packages
Fig1. Full Lead Packages
· MS-001d (see fig1)
Symbol
Dimensions in mil
Min.
Nom.
Max.
A
1230
¾
1280
B
240
¾
280
C
115
¾
195
D
115
¾
150
E
14
¾
22
F
45
¾
70
G
¾
100
¾
H
300
¾
325
I
¾
¾
430
· MS-001d (see fig2)
Symbol
Rev. 1.21
Dimensions in mil
Min.
Nom.
Max.
A
1160
¾
1195
B
240
¾
280
C
115
¾
195
D
115
¾
150
E
14
¾
22
F
45
¾
70
G
¾
100
¾
H
300
¾
325
I
¾
¾
430
53
December 29, 2008
HT46RU22
· MO-095a (see fig2)
Symbol
A
Rev. 1.21
Dimensions in mil
Min.
Nom.
Max.
1145
¾
1185
B
275
¾
295
C
120
¾
150
D
110
¾
150
E
14
¾
22
F
45
¾
60
G
¾
100
¾
H
300
¾
325
I
¾
¾
430
54
December 29, 2008
HT46RU22
24-pin SOP (300mil) Outline Dimensions
1 3
2 4
A
B
1 2
1
C
C '
G
H
D
E
a
F
· MS-013
Symbol
Rev. 1.21
Dimensions in mil
Min.
Nom.
Max.
A
393
¾
419
B
256
¾
300
C
12
¾
20
C¢
598
¾
613
D
¾
¾
104
E
¾
50
¾
F
4
¾
12
G
16
¾
50
H
8
¾
13
a
0°
¾
8°
55
December 29, 2008
HT46RU22
24-pin SSOP (150mil) Outline Dimensions
1 3
2 4
A
B
1 2
1
C
C '
G
H
D
E
Symbol
Rev. 1.21
a
F
Dimensions in mil
Min.
Nom.
Max.
A
228
¾
244
B
150
¾
157
C
8
¾
12
C¢
335
¾
346
D
54
¾
60
E
¾
25
¾
F
4
¾
10
G
22
¾
28
H
7
¾
10
a
0°
¾
8°
56
December 29, 2008
HT46RU22
Product Tape and Reel Specifications
Reel Dimensions
D
T 2
A
C
B
T 1
SOP 24W
Symbol
Description
Dimensions in mm
A
Reel Outer Diameter
330.0±1.0
B
Reel Inner Diameter
100.0±1.5
C
Spindle Hole Diameter
13.0+0.5/-0.2
D
Key Slit Width
T1
Space Between Flange
T2
Reel Thickness
2.0±0.5
24.8+0.3/-0.2
30.2±0.2
SSOP 24S (150mil)
Symbol
Description
Dimensions in mm
A
Reel Outer Diameter
330.0±1.0
B
Reel Inner Diameter
100.0±1.5
C
Spindle Hole Diameter
13.0+0.5/-0.2
D
Key Slit Width
T1
Space Between Flange
T2
Reel Thickness
Rev. 1.21
2.0±0.5
16.8+0.3/-0.2
22.2±0.2
57
December 29, 2008
HT46RU22
Carrier Tape Dimensions
P 0
D
P 1
t
E
F
W
C
D 1
P
B 0
K 0
A 0
R e e l H o le
IC p a c k a g e p in 1 a n d th e r e e l h o le s
a r e lo c a te d o n th e s a m e s id e .
SOP 24W
Symbol
W
Description
Dimensions in mm
Carrier Tape Width
24.0±0.3
P
Cavity Pitch
12.0±0.1
E
Perforation Position
1.75±0.1
F
Cavity to Perforation (Width Direction)
D
Perforation Diameter
1.55+0.10/-0.00
D1
Cavity Hole Diameter
1.50+0.25/-0.00
11.5±0.1
P0
Perforation Pitch
4.0±0.1
P1
Cavity to Perforation (Length Direction)
2.0±0.1
A0
Cavity Length
10.9±0.1
B0
Cavity Width
15.9±0.1
K0
Cavity Depth
3.1±0.1
t
Carrier Tape Thickness
0.35±0.05
C
Cover Tape Width
21.3±0.1
SSOP 24S (150mil)
Symbol
W
Description
Dimensions in mm
16.0+0.3/-0.1
Carrier Tape Width
P
Cavity Pitch
E
Perforation Position
F
Cavity to Perforation (Width Direction)
D
Perforation Diameter
1.5+0.1/-0.0
D1
Cavity Hole Diameter
1.50+0.25/-0.00
P0
Perforation Pitch
8.0±0.1
1.75±0.10
7.5±0.1
4.0±0.1
P1
Cavity to Perforation (Length Direction)
2.0±0.1
A0
Cavity Length
6.5±0.1
B0
Cavity Width
9.5±0.1
K0
Cavity Depth
2.1±0.1
t
Carrier Tape Thickness
0.30±0.05
C
Cover Tape Width
13.3±0.1
Rev. 1.21
58
December 29, 2008
HT46RU22
Holtek Semiconductor Inc. (Headquarters)
No.3, Creation Rd. II, Science Park, Hsinchu, Taiwan
Tel: 886-3-563-1999
Fax: 886-3-563-1189
http://www.holtek.com.tw
Holtek Semiconductor Inc. (Taipei Sales Office)
4F-2, No. 3-2, YuanQu St., Nankang Software Park, Taipei 115, Taiwan
Tel: 886-2-2655-7070
Fax: 886-2-2655-7373
Fax: 886-2-2655-7383 (International sales hotline)
Holtek Semiconductor Inc. (Shanghai Sales Office)
G Room, 3 Floor, No.1 Building, No.2016 Yi-Shan Road, Minhang District, Shanghai, China 201103
Tel: 86-21-5422-4590
Fax: 86-21-5422-4705
http://www.holtek.com.cn
Holtek Semiconductor Inc. (Shenzhen Sales Office)
5F, Unit A, Productivity Building, Gaoxin M 2nd, Middle Zone Of High-Tech Industrial Park, ShenZhen, China 518057
Tel: 86-755-8616-9908, 86-755-8616-9308
Fax: 86-755-8616-9722
Holtek Semiconductor Inc. (Beijing Sales Office)
Suite 1721, Jinyu Tower, A129 West Xuan Wu Men Street, Xicheng District, Beijing, China 100031
Tel: 86-10-6641-0030, 86-10-6641-7751, 86-10-6641-7752
Fax: 86-10-6641-0125
Holtek Semiconductor Inc. (Chengdu Sales Office)
709, Building 3, Champagne Plaza, No.97 Dongda Street, Chengdu, Sichuan, China 610016
Tel: 86-28-6653-6590
Fax: 86-28-6653-6591
Holtek Semiconductor (USA), Inc. (North America Sales Office)
46729 Fremont Blvd., Fremont, CA 94538, USA
Tel: 1-510-252-9880
Fax: 1-510-252-9885
http://www.holtek.com
Copyright Ó 2008 by HOLTEK SEMICONDUCTOR INC.
The information appearing in this Data Sheet is believed to be accurate at the time of publication. However, Holtek assumes no responsibility arising from the use of the specifications described. The applications mentioned herein are used
solely for the purpose of illustration and Holtek makes no warranty or representation that such applications will be suitable
without further modification, nor recommends the use of its products for application that may present a risk to human life
due to malfunction or otherwise. Holtek¢s products are not authorized for use as critical components in life support devices
or systems. Holtek reserves the right to alter its products without prior notification. For the most up-to-date information,
please visit our web site at http://www.holtek.com.tw.
Rev. 1.21
59
December 29, 2008