MEANWELL HDP

HDP-190
190W Dual Output with PFC Function
Features :
Universal AC input / Full range
Built-in active PFC function, PF 0.94
High efficiency up to 86%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
1U low profile 36mm
Conformal coated
ZVS technology to reduce power dissipation
LED indicator for power on
3 years warranty
SPECIFICATION
MODEL
HDP-190
OUTPUT NUMBER
V1
DC VOLTAGE
+3.8V
+2.8V
RATED CURRENT
33A
20A
CURRENT RANGE (max.)
0 ~ 40A
RATED POWER
181.4W (typ.)
OUTPUT POWER (max.)
OUTPUT
V2
0 ~ 22A
192W (max.)
192W continue. V1 total power output shall not exceed 160W (max. 40A) ; V2 total power output shall not exceed 66W (max. 22A)
(The V1 & V2 combine total power output shall not exceed 192W)
RIPPLE & NOISE (max.) Note.2 100mVp-p
100mVp-p
VOLTAGE ADJ. RANGE Note.6 3.6 ~ 4V
VOLTAGE TOLERANCE Note.3 2.0%
2.5 ~ 3V
2.0%
LINE REGULATION
0.5%
LOAD REGULATION
2.0%
0.5%
2.0%
SETUP, RISE TIME
1000ms, 50ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
VOLTAGE RANGE
Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
2500ms, 50ms/115VAC at full load
127 ~ 370VDC
POWER FACTOR (Typ.)
PF 0.94/230VAC
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
86%
2.7A/115VAC
1.1A/230VAC
INRUSH CURRENT (Typ.)
30A/115VAC
45A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC
V1+V2: 105 ~ 150% max. output power ; or V2: 125 ~ 170% rated current
OVERLOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
PF 0.98/115VAC at full load
Protection type: Hiccup mode, recovers automatically after fault condition is removed
V2: 3.22 ~ 3.78V
V1: 4.37 ~ 5.13V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, re-power on to recovery
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
OTHERS
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A
MTBF
111.3K hrs min.
DIMENSION
215*115*36mm (L*W*H)
0.95Kg; 15pcs/15.3Kg/0.7CUFT
PACKING
NOTE
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Output voltage between V1 and V2 should be higher than 0.8V(V1-V2 0.8V).
File Name:HDP-190-SPEC 2012-02-29
HDP-190
190W Dual Output with PFC Function
Mechanical Specification
Case No.206A
Unit:mm
215
204.5
97.5
150
32.5
24
15.85
SVR1
Terminal Pin No. Assignment :
Assignment Pin No.
AC/L
4,5
AC/N
6,7
8,9,10,11
FG
115
108
SVR1: V1(+3.8V)ADJ.
SVR2: V2(+2.8V)ADJ.
44.75
34.4
95
Assignment
V2(+2.8V)
V1(+3.8V)
COM
10
32.5
50
Pin No.
1
2
3
16
3.5
9.5
135
8.3
11
10 LED
9
8
7
4-M4 L=5mm
6 SVR2
5
4
3
2
5-M3 L=3mm
1
15
215
150
32.5
12.5
36
16max.
4-M4 L=5mm
Block Diagram
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
PFC fosc : 65KHz
PWM fosc : 80KHz
RECTIFIERS
&
PFC
POWER
SWITCHING
O.T.P.
O.L.P.
RECTIFIERS
&
FILTER
POWER
SWITCHING
DETECTION
CIRCUIT
FG
PFC
CONTROL
+V1
COM
PWM
CONTROL
O.V.P.
+V2
O.L.P.
PWM
CONTROL
DETECTION
CIRCUIT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
70
50
LOAD(%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
95
100
115
130
145
165
185
205
225
245
264
INPUT VOLTAGE (V) 60Hz
File Name:HDP-190-SPEC 2012-02-29