2014-01-14 Silicon NPN Phototransistor NPN-Silizium-Fototransistor Version 1.1 SFH 310, SFH 310 FA SFH 310 SFH 310 FA Features: Besondere Merkmale: • Spectral range of sensitivity: 450 nm ... 1100 nm (SFH 310), 740 nm ... 1100 nm (SFH 310 FA) • Package: 3mm Radial (T 1), Epoxy • Special: high photosensitivity • Spektraler Bereich der Fotoempfindlichkeit: 450 nm ... 1100 nm (SFH 310), 740 nm ... 1100 nm (SFH 310 FA) • Gehäuse: 3mm Radial (T 1), Harz • Besonderheit: hohe Fotoempfindlichkeit Applications Anwendungen • Photointerrupters • Industrial electronics • For control and drive circuits • Lichtschranken • Industrieelektronik • Messen / Steuern / Regeln Ordering Information Bestellinformation Type: Photocurrent Ordering Code Typ: Fotostrom Bestellnummer λ = 950 nm, Ee = 0.5 mW/cm2, VCE = 5 V IPCE [µA] SFH 310 630 ... 3200 Q62702P0874 SFH 310-2/3 630 ... 2000 Q62702P3595 SFH 310 FA 400 ... 3200 Q62702P1673 SFH 310 FA-2/3 630 ... 2000 Q62702P3596 Note: Only one bin within one packing unit (variation less than 2:1) Anm.: Nur eine Gruppe pro Verpackungseinheit (Streuung kleiner 2:1) 2014-01-14 1 Version 1.1 SFH 310, SFH 310 FA Maximum Ratings (TA = 25 °C) Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating and storage temperature range Betriebs- und Lagertemperatur Top; Tstg Collector-emitter voltage Kollektor-Emitter-Spannung SFH 310 SFH 310 FA -40 ... 100 °C VCE 35 V Collector current Kollektorstrom IC 50 mA Collector surge current Kollektorspitzenstrom (τ < 10 µs) ICS 100 mA Total power dissipation Verlustleistung Ptot 165 mW Thermal resistance Wärmewiderstand RthJA 450 K/W Characteristics (TA = 25 °C) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit SFH 310 SFH 310 FA Wavelength of max. sensitivity Wellenlänge der max. Fotoempfindlichkeit λS max 880 890 nm Spectral range of sensitivity Spektraler Bereich der Fotoempfindlichkeit λ10% 450 ... 1100 740 ... 1100 nm Radiant sensitive area Bestrahlungsempfindliche Fläche A Dimensions of chip area Abmessung der Chipfläche LxW 2014-01-14 2 0.11 mm2 0.5 x 0.5 mm x mm Version 1.1 SFH 310, SFH 310 FA Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit SFH 310 SFH 310 FA Half angle Halbwinkel ϕ ± 25 ° Capacitance Kapazität (VCE = 0 V, f = 1 MHz, E = 0) CCE 7.5 pF Dark current Dunkelstrom (VCE = 10 V, E = 0) ICE0 1 (≤ 50) nA 2014-01-14 3 Version 1.1 SFH 310, SFH 310 FA Grouping (TA = 25 °C, λ = 950 nm) Gruppierung Group Min Photocurrent Max Photocurrent Typ Photocurrent Rise and fall time Gruppe Min Fotostrom Max Fotostrom Typ Fotostrom Ee = 0.5 mW/cm2, VCE = 5 V Ee = 0.5 mW/cm2, VCE = 5 V SFH 310: IC = 1 mA, EV = 1000 lx, Std. VCC = 5 V, Light A, VCE = 5 V RL = 1 kΩ Anstiegs- und Abfallzeit IPCE, min [µA] IPCE, max [µA] IPCE [µA] tr, tf [µs] -2 630 1250 3000 5 -3 1000 2000 4800 8 -4 1600 3200 7700 12 Group Collector-emitter saturation voltage Gruppe Kollektor-Emitter Sättigungsspannung IC = IPCEmin x 0.3, Ee = 0.5 mW/cm2 VCEsat [mV] -2 150 -3 150 -4 150 Note.: IPCEmin is the min. photocurrent of the specified group. Anm.: IPCEmin ist der minimale Fotostrom der jeweiligen Gruppe. 2014-01-14 4 Version 1.1 SFH 310, SFH 310 FA Relative Spectral Sensitivity Relative spektrale Empfindlichkeit SFH 310 FA Srel = f(λ) Relative Spectral Sensitivity Relative spektrale Empfindlichkeit SFH 310 Srel = f(λ) 100 OHF04042 Srel % 100 Srel % 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 400 500 600 700 800 900 0 400 500 600 700 800 900 nm 1100 nm 1100 λ λ Photocurrent Fotostrom IPCE = f(VCE), Ee = Parameter Photocurrent Fotostrom IPCE = f(Ee), VCE = 5 V 2014-01-14 OHF04075 5 Version 1.1 SFH 310, SFH 310 FA Dark Current Dunkelstrom ICEO = f(VCE), E = 0 Photocurrent Fotostrom IPCE / IPCE(25°C) = f(TA), VCE = 5 V Ι PCE OHF04049 10 1 nA OHF01524 1.6 I CEO Ι PCE 25 1.4 1.2 10 0 1.0 0.8 0.6 10 -1 0.4 0.2 0 -25 0 25 50 10 -2 75 C 100 TA 0 5 10 15 20 25 30 V 35 VCE Collector-Emitter Capacitance Kollektor-Emitter Kapazität CCE = f(VCE), f = 1 MHz, E = 0 Dark Current Dunkelstrom ICEO = f(TA), E = 0 OHF04050 10 4 nA OHF04051 8 pF C CE 7 I CEO 10 3 6 10 2 5 10 1 4 3 10 0 2 10 -1 1 10 -2 -25 0 25 50 0 -3 10 75 ˚C 100 TA 2014-01-14 10 -2 10 -1 10 0 10 1 V 10 2 VCE 6 Version 1.1 SFH 310, SFH 310 FA Total Power Dissipation Verlustleistung Ptot = f(TA) Directional Characteristics Winkeldiagramm Srel = f(ϕ) 2014-01-14 7 Version 1.1 SFH 310, SFH 310 FA Package Outline Maßzeichnung 4.8 (0.189) 4.4 (0.173) 1.8 (0.071) 1.2 (0.047) Collector ø2.9 (0.114) ø2.7 (0.106) 1.1 (0.043) 0.9 (0.035) 0.4 (0.016) 0.8 (0.031) 0.4 (0.016) 0.7 (0.028) 0.4 (0.016) 0.6 (0.024) 2.54 (0.100) spacing Area not flat 3.1 (0.122) 3.7 (0.146) 0.6 (0.024) 3.5 (0.138) 6.1 (0.240) 0.4 (0.016) 5.7 (0.224) 29.0 (1.142) 27.0 (1.063) GEXY6710 Dimensions in mm (inch). / Maße in mm (inch). 2014-01-14 3.4 (0.134) 8 Version 1.1 SFH 310, SFH 310 FA TTW Soldering Wellenlöten (TTW) IEC-61760-1 TTW / IEC-61760-1 TTW OHA04645 300 10 s max., max. contact time 5 s per wave ˚C T 250 235 ˚C - 260 ˚C First wave Second wave Continuous line: typical process Dotted line: process limits ΔT < 150 K 200 Cooling Preheating ca. 3.5 K/s typical 150 ca. 2 K/s 130 ˚C 120 ˚C 100 ˚C 100 ca. 5 K/s Typical 50 0 0 20 40 60 80 100 120 140 160 180 200 220 s 240 t 2014-01-14 9 Version 1.1 SFH 310, SFH 310 FA Disclaimer Disclaimer Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. 2014-01-14 10 Version 1.1 SFH 310, SFH 310 FA Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. 2014-01-14 11