NPN-Silizium-Fototransistor Silicon NPN Phototransistor Lead (Pb) Free Product - RoHS Compliant BPX 43 Wesentliche Merkmale Features • Speziell geeignet für Anwendungen im Bereich von 450 nm bis 1100 nm • Hohe Linearität • Hermetisch dichte Metallbauform (TO-18) mit Basisanschluss, geeignet bis 125 °C • Gruppiert lieferbar • Especially suitable for applications from 450 nm to 1100 nm • High linearity • Hermetically sealed metal package (TO-18) with base connection suitable up to 125 °C • Available in groups Anwendungen Applications • Lichtschranken für Gleich- und Wechsellichtbetrieb • Industrieelektronik • „Messen/Steuern/Regeln“ • Photointerrupters • Industrial electronics • For control and drive circuits Typ Type Bestellnummer Ordering Code Fotostrom , Ee= 0.5 mW/cm2, λ = 950 nm, VCE = 5 V Photocurrent Ipce (mA) BPX 43 Q62702P0016 > 0.8 BPX 43-3/4 1) Q62702P3581 1.25…4.0 BPX 43-4 Q62702P0016S004 2.0…4.0 BPX 43-4/5 1) Q62702P3582 > 2.0 BPX 43-5 Q 62702P0016S005 > 3.2 1) nur eine Gruppe in einer Verpackungseinheit (siehe “Kennwerte”) / only one bin within one packing unit (see “Characteristics”) 2007-04-02 1 BPX 43 Grenzwerte Maximum Ratings Bezeichnung Parameter Symbol Symbol Wert Value Einheit Unit Betriebs- und Lagertemperatur Operating and storage temperature range Top; Tstg – 40 … + 125 °C Kollektor-Emitterspannung Collector-emitter voltage VCE 50 V Kollektorstrom Collector current IC 50 mA Kollektorspitzenstrom, τ < 10 μs Collector surge current ICS 200 mA Emitter-Basisspannung Emitter-base voltage VEB 7 V Verlustleistung, TA = 25 °C Total power dissipation Ptot 220 mW Wärmewiderstand Thermal resistance RthJA 450 K/W 2007-04-02 2 BPX 43 Kennwerte (TA = 25 °C, λ = 950 nm) Characteristics Bezeichnung Parameter Symbol Symbol Wert Value Einheit Unit Wellenlänge der max. Fotoempfindlichkeit Wavelength of max. sensitivity λS max 880 nm Spektraler Bereich der Fotoempfindlichkeit S = 10% von Smax Spectral range of sensitivity S = 10% of Smax λ 450 … 1100 nm Bestrahlungsempfindliche Fläche Radiant sensitive area A 0.675 mm2 Abmessung der Chipfläche Dimensions of chip area L×B L×W 1×1 mm × mm Halbwinkel Half angle ϕ ± 15 Grad deg. IPCB IPCB 11 35 μA μA CCE CCB CEB 23 39 47 pF pF pF ICEO 20 (≤ 100) nA Fotostrom der Kollektor-Basis-Fotodiode Photocurrent of collector-base photodiode Ee = 0.5 mW/cm2, VCB = 5 V Ev = 1000 Ix, Normlicht/standard light A, VCB = 5 V Kapazität Capacitance VCE = 0 V, f = 1 MHz, E = 0 VCB = 0 V, f = 1 MHz, E = 0 VEB = 0 V, f = 1 MHz, E = 0 Dunkelstrom Dark current VCE = 25 V, E = 0 2007-04-02 3 BPX 43 Die Fototransistoren werden nach ihrer Fotoempfindlichkeit gruppiert und mit arabischen Ziffern gekennzeichnet. The phototransistors are grouped according to their spectral sensitivity and distinguished by arabian figures. Bezeichnung Parameter Symbol Symbol Wert Value -2 Fotostrom, λ = 950 nm Photocurrent Ee = 0.5 mW/cm2, VCE = 5 V IPCE Ev = 1000 Ix, Normlicht/standard light A, IPCE VCE = 5 V -3 -4 Einheit Unit -5 0.8 …1.6 1.25 …2.5 2.0…4.0 ≥ 3.2 3.8 6.0 9.5 15.0 mA mA Anstiegszeit/Abfallzeit Rise and fall time IC = 1 mA, VCC = 5 V, RL = 1 kΩ tr , t f 9 12 15 18 μs Kollektor-Emitter-Sättigungsspannung Collector-emitter saturation voltage IC = IPCEmin1) × 0.3 Ee = 0.5 mW/cm2 VCEsat 200 220 240 260 mV Stromverstärkung Current gain Ee = 0.5 mW/cm2, VCE = 5 V I PCE -----------I PCB 110 170 270 430 – 1) IPCEmin ist der minimale Fotostrom der jeweiligen Gruppe. 1) IPCEmin is the min. photocurrent of the specified group. 2007-04-02 4 BPX 43 Relative Spectral Sensitivity Srel = f (λ) Photocurrent IPCE = f (Ee), VCE = 5 V Total Power Dissipation Ptot = f (TA) Output Characteristics IC = f (VCE), IB = Parameter Output Characteristics IC = f (VCE), IB = Parameter Dark Current ICEO = f (VCE), E = 0 Photocurrent IPCE/IPCE25o = f (TA), VCE = 5 V Dark Current ICEO/ICEO25o = f (TA), VCE = 25 V, E = 0 Collector-Emitter Capacitance CCE = f (VCE), f = 1 MHz, E = 0 2007-04-02 5 BPX 43 Collector-Base Capacitance CCB = f (VCB), f = 1 MHz, E = 0 Emitter-Base Capacitance CEB = f (VEB), f = 1 MHz, E = 0 Directional Characteristics Srel = f (ϕ) 2007-04-02 6 BPX 43 Maßzeichnung Package Outlines ø4.6 (0.181) ø0.45 (0.018) ø4.8 (0.189) (2.7 (0.106)) 0.9 1.1 (0 (0 .04 .03 5) 14.5 (0.571) 5.1 (0.201) 12.5 (0.492) 4.8 (0.189) 6.2 (0.244) 3) E C B ø5.6 (0.220) ø5.3 (0.209) 5.4 (0.213) GMOY6019 Maße in mm (inch) / Dimensions in mm (inch) 2007-04-02 3) .0 04 5) ( 03 1.1 (0. 0.9 2.54 (0.100) spacing Radiant sensitive area Chip position 7 BPX 43 Lötbedingungen Soldering Conditions Wellenlöten (TTW) TTW Soldering (nach CECC 00802) (acc. to CECC 00802) OHLY0598 300 C T 10 s 250 Normalkurve standard curve 235 C ... 260 C Grenzkurven limit curves 2. Welle 2. wave 200 1. Welle 1. wave 150 ca 200 K/s 2 K/s 5 K/s 100 C ... 130 C 100 2 K/s 50 Zwangskühlung forced cooling 0 0 50 100 150 200 s 250 t Published by OSRAM Opto Semiconductors GmbH Wernerwerkstrasse 2, D-93049 Regensburg www.osram-os.com © All Rights Reserved. The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components 1 , may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS. 1 A critical component is a component usedin a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system. 2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered. 2007-04-02 8