RBU1501M THRU RBU1507M SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 15.0 Amperes FEATURES Low leakage Low forward voltage Surge overload rating : 250 amperes peak Mounting position: Any Ideal for printed circuit boards High forward surge current capability RBU MECHANICAL DATA .880 (22.3) .860 (21.8) * Epoxy: Device has UL flammability classification 94V-O * UL list the recognized component directory,file #E94233 .140 (3.56) .130 (3.30) .512 (13.0) .740 (18.8) .720 (18.3) .160 (4.1) .140 (3.5) .080 (2.03) .060 (1.52) * * * * * * .085 (2.16) .075 (1.90) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS o Ratings at 25 C ambient temperature unless otherwise specified. resistive or inductive load. .210 (5.33) .190 (4.83) .080 (2.03) .065 (1.65) .050 (1.27) .040 (1.02) .710 (18.0) .690 (17.5) .100 (2.54) .085 (2.16) .022 (0.56) .018 (0.46) Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS SYMBOL RBU1501M RBU1502M RBU1503M RBU1504M RBU1505M RBU1506M RBU1507M UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current o at T C = *100 C (Note 4) Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time Isolation Voltage of case Typical Thermal Resistance (Note 1) Operating and Storage Temperature Range Volts IO 15.0 Amps I FSM 250 Amps I 2t 259.3 2 A /S VISO 1600 V AC R θJC 1.5 R θ JA 22 T J, T STG -55 to + 150 0 C/ W 0 C ELECTRICAL CHARACTERISTICS(@TA=25 C unless otherwise noted) O CHARACTERISTICS Maximum Instantaneous Forward Voltage at 7.5A DC Maximum DC Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 o C SYMBOL RBU1501M RBU1502M RBU1503M RBU1504M RBU1505M RBU1506M RBU1507M VF IR NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 3. Equivalent to Vishay's GBU10 Series. 4. "*" Heat Sink Temperature. 5. Available in Halogen-free epoxy by adding suffix -HF after the part nbr. 1.1 5.0 100 UNITS Volts uAmps 2013-04 REV: A 60 10 50 POWER DISSIPATION, (W) 30 20 TC= 150 OC (TYP) 5 TC= 25 OC (TYP) 2 1 0.5 0.2 0.2 0.4 0.6 0.8 1 1.2 1.4 30 20 10 0 4 12 16 20 AVERAGE RECTIFIED FORWARD CURRENT, (A) FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERITICS FIG.2 POWER DISSIPATION 4 sine wave 300 0 250 8.3ms 8.3ms 1 cycle non-repetitive Tj=25 200 150 100 50 1 2 5 10 20 50 3 P.C.B soldering land 5mmf sine wave R-load free in air 2 1 0 100 0 40 80 120 160 AMBIENT TEMPERATURE, (OC) FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE FIG.3 SURGE FORWARD CURRENT CAPABILITY 15 THERMAL RESISTANCE (OC/W) 1.2 12 9 heatsink Tc Tc 6 3 0 10 24 on glass-epoxi substrate NUMBER OF CYCLE AVERAGE FORWARD CURRENT, (A) 8 INSTANTANEOUS FORWARD VOLTAGE, (V) 350 0 sine wave TJ = 150 OC 40 0 1.6 AVERAGE FORWARD CURRENT, (A) 0 Pulse test per one diode IFSM PEAK FORWARD SURGE CURRENT, (A) INSTANTANEOUS FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RBU1501M THRU RBU1507M ) sine wave R-load on heatsink 30 50 70 90 110 130 150 HEAT SINK TEMPERATURE, (OC) FIG.5 TYPICAL FORWARD CURRENT DERATING CURVE 170 with thermal compound 1.0 0.8 0.6 0.4 0.2 0 2 3 4 5 6 7 MOUNTING TORQUE (kg.cm) FIG.6 CONTACT THERMAL RESISTANCE fcf 8 Marking Description Rectron Logo RBU150XM Part No. Voltage-code UL Logo V Y WW Year – code: (Y:Last digit of year A:2010, B: 2011...) Week – code: (WW:01~52) 1-------50V 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS TUBE PACK PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE (mm) (mm) RBU -C 1,000 490*135*110 510*293*131 EA PER CARTON WEIGHT(Kg) 2,000 13.62 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.