RECTRON RS2001M_10

RS2001M
THRU
RS2007M
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 20 Amperes
FEATURES
Low leakage
Low forward voltage
Surge overload rating : 300 amperes peak
Mounting position: Any
Ideal for printed circuit boards
High forward surge current capability
RS-20M
.189 (4.8)
.173 (4.4)
.197 (5)
.165 (4.2)
.150 (3.8)
.106 (2.7)
.096 (2.3)
.087 (2.2)
.071 (1.8)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.800 (20.3)
.775 (19.7)
* Epoxy: Device has UL flammability classification 94V-O
* UL list the recognized component directory,file #E94233
f .138 (3.5)
.126 (3.2)
.150 (3.8)
.134 (3.4)
1.193 (30.3)
1.169 (29.7)
.441 (11.2)
.425 (10.8)
MECHANICAL DATA
.114 (2.9)
.098 (2.5)
.708 (18.0)
.669 (17.0)
*
*
*
*
*
*
.043 (1.1)
.035 (0.9)
Ratings at 25 o C ambient temperature unless otherwise specified.
resistive or inductive load.
.031 (0.8)
.023 (0.6)
.402 (10.2) .303 (7.7) .303 (7.7)
.386 (9.8) .287 (7.3) .287 (7.3)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS
SYMBOL
RS2001M RS2002M RS2003M RS2004M RS2005M RS2006M RS2007M
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T C = 55 o C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squared Time
IO
20
Amps
I FSM
300
Amps
2
373.3
A 2S
I T
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
R q JC
1.5
R q JA
22
T J, T STG
-55 to + 150
0
C/ W
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 10A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25 o C
@T A = 100 o C
SYMBOL
RS2001M RS2002M RS2003M RS2004M RS2005M RS2006M RS2007M
UNITS
VF
1.1
Volts
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
5.0
100
uAmps
2010-01
REV:A
30
20
60
10
50
POWER DISSIPATION, (W)
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( RS2001M THRU RS2007M )
TC= 150 OC (TYP)
5
TC= 25 OC (TYP)
2
1
0.5
0.2
0
Pulse test
per one diode
0.2
0.4
0.6
0.8
1
1.2
1.4
40
30
20
10
0
1.6
sine wave
TJ = 150 OC
0
INSTANTANEOUS FORWARD VOLTAGE, (V)
0
8.3ms 8.3ms
200
1 cycle
non-repetitive
T j=25
100
0
0
1
2
5
10
20
50
1
0
100
s oldering land 5mmf
s ine wave
R -load
free in air
2
0
40
THERMAL RESISTANCE (OC/W)
AVERAGE FORWARD CURRENT, (A)
heats ink
Tc
Tc
8
s ine wave
R -load
on heats ink
90
110
120
160
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
1.0
70
80
AMBIENT TEMPERATURE, (OC)
16
50
24
P .C .B
1.2
30
20
3
20
0
10
16
on glas s -epoxi s ubs trate
FIG.3 SURGE FORWARD CURRENT CAPABILITY
4
12
4
NUMBER OF CYCLE
12
8
FIG.2 POWER DISSIPATION
AVERAGE FORWARD CURRENT, (A)
s ine wave
IF S M
PEAK FORWARD SURGE CURRENT, (A)
FIG.1 TYPICAL INSTANTANEOUS FORWARD
CHARACTERITICS
300
4
AVERAGE RECTIFIED FORWARD CURRENT, (A)
130
HEAT SINK TEMPERATURE, (OC)
150
FIG.5 TYPICAL FORWARD CURRENT
DERATING CURVE
170
with thermal compound
0.8
0.6
0.4
0.2
0
2
3
4
5
6
7
MOUNTING TORQUE (kg.cm)
FIG.6 CONTACT THERMAL RESISTANCE fcf
8
Marking Description
Rectron Logo
Part No.
RS200XM
Voltage-code
UL Logo
V Y WW
Year – code:
(Y:Last digit of year)
Week – code:
(WW:01~52)
1-------50V
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7-------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
EA PER BOX
INNER BOX SIZE
CARTON SIZE
PACKING CODE
RS-20M
-B
300
230*190*46
410*243*157
1,800
13.37
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE
CARTON SIZE
EA PER CARTON
WEIGHT(Kg)
RS-20M
-C
600
490*135*110
510*293*131
1,200
13.12
(mm)
(mm)
EA PER CARTON
GROSS
WEIGHT(Kg)
PACKAGE
TUBE PACK
(mm)
(mm)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.