RECTRON MP3505_11

MP3505
THRU
MP3510
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 35 Amperes
FEATURES
*
*
*
*
Superior thermal design
400 amperes surge rating
1/4" universal faston terminal
Hole thru for # 10 screw
1.142 (29)
1.102 (28)
.732 (18.6)
.693 (17.6)
1.102 (28)
.634 (16.1)
1.142 (29)
.673 (17.1)
.732 (18.6)
.693 (17.6)
Hole for # 10
screw Min. F.
.200 (5.08)
Hole for # 10
screw Min. F.
.200 (5.08)
1.142 (29)
1.102 (28)
1.142 (29)
1.102 (28)
.673 (17.1)
.634 (16.1)
.469 (11.9)
.429 (10.9)
.480 (12.2)
.425 (10.8)
F. .043 (1.1)
F. .039 (1.0)
* Epoxy: Device has UL flammability classification 94V-O
* UL listed on recognized component directory, file #E94233
MIN. .787 (20.0)
MAX.
.311(7.9)
MECHANICAL DATA
MAX.
.311(7.9)
MP-35 / MP-35W
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.583 (14.8)
.543 (13.8)
Ratings at 25 o C ambient temperature unless otherwise specified.
resistive or inductive load.
.32 x .252 (0.81 x 6.35)
.732 (18.6)
.693 (17.6)
MP-35
MP-35W
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
MP3505
MP351
MP352
MP354
MP356
MP358
MP3510
UNITS
Maximum Recurrent Peak Reverse Voltage
RATINGS
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T C = 55 o C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squarad Time
RMS isolation voltage from case to lead
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
IO
35
Amps
I FSM
400
Amps
I2t
663.7
A 2 /Sec
VISO
2500
Volts
R q JC
1.4
R q JA
19
T J, T STG
-55 to + 150
0
C/ W
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 17.5A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25 o C
@T A = 100 o C
SYMBOL
MP3505
VF
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
3. Suffix "W" for wire type.
MP351
MP352
MP354
1.1
MP356
MP358
MP3510
UNITS
Volts
5.0
500
uAmps
2011-02
REV:C
30
20
10
5
2
1
0.5
0.2
0
Pulse test
per one diode
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( MP3505 THRU MP3510 )
100
TA = 25 OC
10
1.0
0.1
0
INSTANTANEOUS FORWARD VOLTAGE, (V)
0
400
8.3ms 8.3ms
1 cycle
non-repetitive
Tj=25
300
200
100
0
0
1
2
5
10
20
50
100
NUMBER OF CYCLE
FIG.3 SURGE FORWARD CURRENT CAPABILITY
40
60
80
100
120
140
FIG.2 TYPICAL REVERSE CHARACTERISTICS
AVERAGE FORWARD CURRENT, (A)
sine wave
IFSM
PEAK FORWARD SURGE CURRENT, (A)
FIG.1 TYPICAL INSTANTANEOUS FORWARD
CHARACTERITICS
500
20
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
50
40
30
20
10
0
10
30
50
70
90
110
130
150
HEAT SINK TEMPERATURE, (OC)
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
170
Marking Description
+
AC
Part No.
MP35X
Rectron Logo
VYWW
Year – code:
(Y:Last digit of year)
Voltage-code
05-------50V
1-------100V
2-------200V
4-------400V
6-------600V
8-------800V
10-----1000V
UL Logo
Week – code:
(WW:01~52)
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
MP-35(W)
-B
EA PER BOX
50
INNER BOX SIZE
(mm)
203*205*57
CARTON SIZE
(mm)
450*220*255
EA PER CARTON
400
GROSS
WEIGHT(Kg)
7.7 (8.26)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.