SLPOWER GPFC110-24

GPFC110 Commercial
110 Watt Global Performance Switchers
110 WATT GLOBAL PERFORMANCE SWITCHERS
FEATURES:
• 3.1 watts/cu.in. power density
• Compact size (6.3” x 3.75” x 1.62”;
meets 1U height)
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 μA leakage
• EMI compliance to CISPR 22, FCC Class B
• Approved to UL1950, IEC950 and
CSA 22.2 No. 950
• 2-year warranty
•
marked to LVD
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
85-264 Vac, 47-63 Hz single phase.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the EMC requirements below.
Input Current
Maximum input current 2.3 A at 90 Vac, 60 Hz with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2.
EMI SPECIFICATIONS
COMPLIANCE LEVEL
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A
Hold-up Time
25 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
110 W fan cooled, 75 W convection. Peak ratings are for 60 s maximum duration, 10% duty cycle.
Total Regulation
Total regulation is the maximum deviation from the nominal voltage for all
steady-state loading conditions.
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold
start conditions. Limiting provided by internal thermistors.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic.
Fan Output
An additional output, same as Vout, suitable for powering a dc fan is included in all
models. The output is protected by an internal resistor in the event of an overload.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
Power Fail
TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage
drops more than 4% below nominal voltage upon loss of ac power. The signal is
factory set to trip when input power can no longer sustain the output.
Transient Response
500 μs typical response time for return to within 0.5% of final value for a 50%
load step change, ∆i/∆ t< 0.2 A/μs. Maximum voltage deviation is 3.5%. Load
must not go below stated minimum.
Remote Sense
Provided as a standard feature. Capable of compensating for 0.25 V total of
cabling losses in voltage. Open sense lead protection.
Overvoltage Protection
OVP crowbar reduces output voltage below nominal rating in less than 50 ms.
Voltage Adjustment: Main output ±5%.
Input Protection
Internal ac fuse provided on all models. Fuse does not blow on overload or
short circuit—fuse blows only if catastrophic failure occurs in the unit.
Temperature Coefficient
0.03%/°C typical on all outputs.
Environmental
Designed for 0 to 50°C operation at full rated output power; derate output current
and total output power by 2.5% per °C above 50°C. See Environmental and Packaging Specifications on the next page.
Commercial Safety Approvals
All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB
certificate available. Exceeds FCC and CISPR22 Class B conducted emissions
requirement
All specifications are typical at nominal input, full load at 25OC unless otherwise stated
Commercial
Model
Output No.
Output
Output
Minimum (A)
Output
Maximum (A)
Output
Maximum (B)
Total
Regulation
OVP Setpoint
Notes
GPFC 110-5
1
5.1 v
0A
11 A
15 A
2%
6.2 ± 0.6 V
C
GPFC 110-12
1
12 V
0A
6.7 A
9.2 A
2%
14 ± 1.1 V
C
GPFC 110-15
1
15 V
0A
5.3 A
7.3 A
2%
18.5 ± 1.5 V
C
GPFC 110-24
1
24 V
0A
3.4 A
4.6 A
2%
28 ± 2.5 V
C
GPFC110-28
1
28 V
0A
2.9 A
3.9 A
2%
34 ± 2.8 V
C
GPFC110-48
1
48 V
0A
1.7 A
2.3 A
2%
55 ± 4 V
C
Notes:
A. With unrestricted convection cooling.
B. With 26cfm airflow.
C. Add “G” suffix to part number for RoHS compliant model.
GPFC110 MECHANICAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
OPERATING
NON-OPERATING
Temperature (A)
See Individual Specs.
-40 to +85°C
Humidity (A)
0 to 95% RH
0 to 95% RH
Shock (B)
20 gpk
40 gpk
Altitude
-500 to 10,000 ft
-500 to 40,000 ft
Vibration (C)
1.5 g rms’ 0.003 g /Hz
5 g rms’ 0.026 g2/Hz
2
A.
B.
C.
Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction,
3 orthogonal axes, total 6 shocks.
Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.
SL Power Electronics., 6050 King Drive, Bldg A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: [email protected] Rev. 8/12 Data Sheet © 2009
SL Power Electronics Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.