GPFC110 Commercial 110 Watt Global Performance Switchers 110 WATT GLOBAL PERFORMANCE SWITCHERS FEATURES: • 3.1 watts/cu.in. power density • Compact size (6.3” x 3.75” x 1.62”; meets 1U height) • Power factor corrected to IEC 1000-3-2 Class A • Less than 300 μA leakage • EMI compliance to CISPR 22, FCC Class B • Approved to UL1950, IEC950 and CSA 22.2 No. 950 • 2-year warranty • marked to LVD • RoHS Compliant Model Available (G suffix) SPECIFICATIONS Ac Input 85-264 Vac, 47-63 Hz single phase. EMI/EMC Compliance All models include built-in EMI filtering to meet the EMC requirements below. Input Current Maximum input current 2.3 A at 90 Vac, 60 Hz with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2. EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics EN55022 Class B; FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. EN61000-3-2 Class A Hold-up Time 25 ms minimum from loss of ac input at full load, nominal line (115 Vac). Output Power 110 W fan cooled, 75 W convection. Peak ratings are for 60 s maximum duration, 10% duty cycle. Total Regulation Total regulation is the maximum deviation from the nominal voltage for all steady-state loading conditions. Inrush Current Inrush 240 Vac is less than 37 A, averaged over the first ac half-cycle under cold start conditions. Limiting provided by internal thermistors. Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Recovery after fault is automatic. Fan Output An additional output, same as Vout, suitable for powering a dc fan is included in all models. The output is protected by an internal resistor in the event of an overload. Output Noise 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Power Fail TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage drops more than 4% below nominal voltage upon loss of ac power. The signal is factory set to trip when input power can no longer sustain the output. Transient Response 500 μs typical response time for return to within 0.5% of final value for a 50% load step change, ∆i/∆ t< 0.2 A/μs. Maximum voltage deviation is 3.5%. Load must not go below stated minimum. Remote Sense Provided as a standard feature. Capable of compensating for 0.25 V total of cabling losses in voltage. Open sense lead protection. Overvoltage Protection OVP crowbar reduces output voltage below nominal rating in less than 50 ms. Voltage Adjustment: Main output ±5%. Input Protection Internal ac fuse provided on all models. Fuse does not blow on overload or short circuit—fuse blows only if catastrophic failure occurs in the unit. Temperature Coefficient 0.03%/°C typical on all outputs. Environmental Designed for 0 to 50°C operation at full rated output power; derate output current and total output power by 2.5% per °C above 50°C. See Environmental and Packaging Specifications on the next page. Commercial Safety Approvals All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB certificate available. Exceeds FCC and CISPR22 Class B conducted emissions requirement All specifications are typical at nominal input, full load at 25OC unless otherwise stated Commercial Model Output No. Output Output Minimum (A) Output Maximum (A) Output Maximum (B) Total Regulation OVP Setpoint Notes GPFC 110-5 1 5.1 v 0A 11 A 15 A 2% 6.2 ± 0.6 V C GPFC 110-12 1 12 V 0A 6.7 A 9.2 A 2% 14 ± 1.1 V C GPFC 110-15 1 15 V 0A 5.3 A 7.3 A 2% 18.5 ± 1.5 V C GPFC 110-24 1 24 V 0A 3.4 A 4.6 A 2% 28 ± 2.5 V C GPFC110-28 1 28 V 0A 2.9 A 3.9 A 2% 34 ± 2.8 V C GPFC110-48 1 48 V 0A 1.7 A 2.3 A 2% 55 ± 4 V C Notes: A. With unrestricted convection cooling. B. With 26cfm airflow. C. Add “G” suffix to part number for RoHS compliant model. GPFC110 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) See Individual Specs. -40 to +85°C Humidity (A) 0 to 95% RH 0 to 95% RH Shock (B) 20 gpk 40 gpk Altitude -500 to 10,000 ft -500 to 40,000 ft Vibration (C) 1.5 g rms’ 0.003 g /Hz 5 g rms’ 0.026 g2/Hz 2 A. B. C. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. SL Power Electronics., 6050 King Drive, Bldg A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: [email protected] Rev. 8/12 Data Sheet © 2009 SL Power Electronics Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.