SLPOWER GLD150

GLD150 Gold Performance Medical Switchers
150 Watt Multiple Output
PERFORMANCE MEDICAL SWITCHERS
FEATURES:
• Compact 4.5” x 7” x 1.7” size
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 μA leakage
• EMI compliance to CISPR11, FCC Class B
• Power fail and remote sense standard
• Medical Approved to UL2601-1, IEC601-1/60601-1
and CSA-C22.2 No. 601.1
• 2 year warranty
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
2.8 A line current maximum, at 90 Vac, 60 Hz with full rated load, power factor
.99 typical, .96 minimum. Input current harmonic content meets the requirements of IEC1000-3-2.
Output Power
150 W with convection cooling, 180 W with fan cooling. Peak ratings are for
60 s maximum duration, 10% duty cycle.
Efficiency
Minimum 80% at full rated load with 230 Vac Input. Approximately 3% less at
115 Vac.
Hold-Up Time
Outputs will remain within regulation limits for 25 ms minimum from loss of
ac input at full load, 10 ms before Power Fail indication.
Output Regulation
Total regulation is the maximum deviation from the nominal voltage for all
steady state loading conditions.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit.
Inhibit
Inhibit signal is pulled to the V1 output common to reduce average output voltage
to less than 5% of nominal.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the EMC requirements of IEC601-1.
Unless otherwise stated, all tests are done at full load and 115 and 230 Vac input.
EMI SPECIFICATIONS
COMPLIANCE LEVEL
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Conducted RF Susceptibility
Voltage Sags & Surges
EN55011, Class B; FCC Class B
EN61000-4-2, 6 kV contact 8 kV air
EN61000-4-3, 3V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-4-6, 3V
EN61000-4-11
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first ac halfcycle under cold
start conditions. Limiting provided by internal thermistors.
Fan Output
An additional 12 Vdc, 250 mA output suitable for powering a dc fan is included in
all models. The fan output is both current limited and thermally protected.
Minimum Load
No minimum load required to maintain output specifications.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit from prolonged over
temperature.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
Power Fail
TTL / CMOS compatible output goes low (<0.5 V) 8 ms before output voltage
drops more than 4% below nominal voltage upon loss of ac power.
Transient Response
Main Output - 500 μs typical response time for return to within 0.5% of final
value for a 50% load step change, di/dt< 0.2 A μs. Maximum voltage deviation is 3%.
Power Good
TTL / CMOS compatible output goes high more than 100 ms after V1 reaches
regulation and should assure that sufficient energy is stored in the input section to
provide normal power fail/shutdown.
Remote Sense
Standard feature on all models, includes open sense lead protection.
Medical Approvals
All models are Certified to be in compliance with the applicable requirements of
UL2601-1, CSA-C22.2 No. 601.1, IEC601-1/60601-1.
Overvoltage Protection
Built in on all models.
Input Protection
Internal ac fuses provided on both lines on all units.
Voltage Adjustment
Output Voltage is adjustable +/- 5% with user adjustable potentiometer.
Temperature Coefficient
0.03% / °C typical on all outputs.
Overshoot
Less than 2% overshoot at turn-on under all conditions, less than 1% overshoot at turn-off under all conditions.
Leakage Current
70 μA, 132 Vac @ 60 Hz normal conditions. Single fault conditions, 130 μA, 254 Vac
@ 50 Hz.
Design Verification Documents
The “Gold” series has undergone rigorous review and design analysis. The following product documentation is available upon request;
1. MTBF study
2. DVT Data
3. EMC / Susceptibility test results
All specifications are typical at nominal input, full load at 25OC unless otherwise stated
Medical
Model
RoHS
Suffix*
Output
Voltage
Output
Current (A)
Output
Current (B)
Voltage
Adjustment
Total
Regulation
OVP
Setpoint
Ripple
and Noise
GLD150-12
G
12 V
12.5 A
15 A
± 5%
GLD150-15
G
15 V
10 A
12 A
± 5%
2%
14 ± 1.1 V
1%
2%
18.5 ± 1.5 V
1%
GLD150-24
G
24 V
6.2 A
7.5 A
GLD150-28
G
28 V
5.3 A
6.4 A
± 5%
2%
28 ± 2.5 V
1%
± 5%
2%
34 ± 2.8 V
1%
GLD150-48
G
48 V
3.2 A
3.75 A
± 5%
2%
55 ± 4.0 V
1%
Notes:
* Add “G” suffix to part number for RoHS compliant model. Contact factory for availability.
A. Maximum continuous current rating for unrestricted convection cooling.
B. Maximum continuous current rating with 150 LFM air or peak rating.
C. Add “C” suffix for cover option and derate convection rating to 130 W.
GLD150 MECHANICAL SPECIFICATIONS
INPUT
J1
MOLEX P.C.B. HEADER P/N: 39-30-2056
PIN 1) AC GROUND
PIN 2) N/C
PIN 3) AC NEUTRAL
PIN 4) N/C
PIN 5) AC LINE
MATING CONNECTOR MOLEX P/N
HOUSING 39-01-4051
CONTACT 39-00-0182
SIGNALS
J2
AMP P.C.B. HEADER P/N 641215-6
PIN 1) INHIBIT
PIN 2) +SENSE
PIN 3) POWER GOOD
PIN 4) -SENSE
PIN 5) COMMON
PIN 6) POWER FAIL
MATING CONNECTOR AMP P/N
HOUSING 770602-6
CONTACT 770666-2
OUTPUT
J3
MOLEX P.C.B. HEADER P/N: 39-29-9085
PINS 3,4,7,8) +Vout
PINS 1,2,5,6) RETURN
MATING CONNECTOR MOLEX P/N
HOUSING 39-01-2080
CONTACT 39-00-0182
FAN
AMP P.C.B. HEADER P/N: 641215-2
PINS 1) RTN
PINS 2) +12V
MATING CONNECTOR AMP P/N
HOUSING 770602-2
CONTACT 770666-02
Cover option: P/N 08-30466-0150
Cover with fan option: P/N 09-150CF
ENVIRONMENTAL SPECIFICATIONS
OPERATING
NON-OPERATING
Temperature (A, D)
0 to +50°C
-40 to +85°C
Humidity (A)
0 to 95% RH
0 to 95% RH
Shock (B)
20 gpk
40 gpk
Altitude
-500 to 10,000 ft
-500 to 40,000 ft
Vibration (C)
1.5 g rms’ 0.003 g /Hz
5 g rms’ 0.026 g2/Hz
2
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3
orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1
hr./axis non-operating.
D. Derate output power to 50% at 70°C.
SL Power Electronics, Inc. 6050 King Drive, Bldg A, Ventura, CA, 93003, USA. Phone: (805) 486 4565 Fax: (805) 487 8911 Email: [email protected]. www.slpower.com Rev.
06/07. Data Sheet © 2006 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.