Series AM30E-Z 30Watt | DC-DC Converter FEATURES: Models Single output Model • • • • • • Wide 2:1 Input Range 1600 VDC I/O Isolation Adjustable Output Voltage Soft Start Over Current & Over Voltage Protection Over Temperature Protection Input Voltage (V) • • • • • Output Voltage (V) Output Current max (A) 3.3 5 5.1 12 15 3.3 5 5.1 12 15 3.3 5 5.1 12 15 8 6 6 2.5 2 8 6 6 2.5 2 8 6 6 2.5 2 Output Voltage (V) Output Current max (mA) AM30E-1203SZ 9-18 AM30E-1205SZ 9-18 AM30E-1205.1SZ 9-18 AM30E-1212SZ 9-18 AM30E-1215SZ 9-18 AM30E-2403SZ 18-36 AM30E-2405SZ 18-36 AM30E-2405.1SZ 18-36 AM30E-2412SZ 18-36 AM30E-2415SZ 18-36 AM30E-4803SZ 36-75 AM30E-4805SZ 36-75 AM30E-4805.1SZ 36-75 AM30E-4812SZ 36-75 AM30E-4815SZ 36-75 Add suffix “-K” for optional heat sink Models Dual output Model Input Voltage (V) Efficiency up to 92% Temperature Range -40ºC to +75ºC Remote On/Off Function Continuous Short Circuit Protection No Minimum Load Required Maximum Capacitive Load (uF) Efficiency (%) 20000 14000 14000 2000 2000 20000 14000 14000 2000 2000 20000 14000 14000 2000 2000 89 91 92 91 92 91 92 92 92 92 90 91 91 91 91 Maximum Capacitive Load (uF) Efficiency (%) AM30E-1205DZ 9-18 ±5 ±3 ±3000 89 AM30E-1212DZ 9-18 ±12 ±1.25 ±1300 90 AM30E-1215DZ 9-18 ±15 ±1 ±1300 91 AM30E-2405DZ 18-36 ±5 ±3 ±3000 90 AM30E-2412DZ 18-36 ±12 ±1.25 ±1300 91 AM30E-2415DZ 18-36 ±15 ±1 ±1300 91 AM30E-4805DZ 36-75 ±5 ±3 ±3000 90 AM30E-4812DZ 36-75 ±12 ±1.25 ±1300 90 AM30E-4815DZ 36-75 ±15 ±1 ±1300 90 Add suffix “-K” for optional heat sink NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating www.aimtec.com F 051e R12.E Nominal 12 24 48 12 24 48 Typical 9-18 18-36 36-75 π (Pi) Network 30 -0.7 ~ 25 -0.7 ~ 50 -0.7 ~ 100 Tel: +1 514 620 2722 1 of 5 Maximum Units VDC ms VDC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30E-Z 30Watt | DC-DC Converter Input Specifications (continued) Parameters Nominal Peak Input Voltage time On/Off control Maximum Units 100 ms ON: 3 ~12VDC or open circuit ; OFF - 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3 12V ON/OFF 8.6 / 7.9 24V ON/OFF 17.8 / 16 VDC 48V ON/OFF 33.5 / 30.5 Under voltage lockout Isolation Specifications Parameters Tested I/O voltage Case/Input tested voltage Resistance Capacitance Conditions Typical 3 sec 3 sec Output Specifications Parameters Cross Regulation (Dual Output Models) Over voltage protection Over current protection Short Circuit protection Short circuit restart Thermal shutdown Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Voltage adjustment range (single) Minimum Load Current General Specifications Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation Rated 1600 1600 1000 1500 Conditions Voltage accuracy Parameters Typical Typical 25% load on one output 100% load on second load ±5 20MHz Bandwidth Conditions Typical 330 -40 to +125 VDC VDC MOhm pF Units % % Zener diode clamp 150 Continuous Auto-Recovery 115 ±0.5 ±0.5 ±1 ±0.02 100 ±10 0 On Case HL-LL 0 – 100% load 0 – 100% load 100% load Derating above 50 Maximum ±1 Units % ºC % % % %/oC mV p-p % % of Max Maximum -40 to +75 2 Free Air Convection 105 95 Nickel coated Copper 31 2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm >435,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours 1.5mm from case for 10 sec 260 250 ±3 Units KHz o C o C o C o %/ C % RH g o C mS % Safety Specifications Parameters Agency Approvals Standards www.aimtec.com F 051e R12.E CE EN55022 Class A IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria A (external 220uF/100V cap required) Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30E-Z 30Watt | DC-DC Converter Safety Specifications (continued) Parameters IEC61000-4-5, Perf. Criteria A (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A NOTE: also designed to meet IEC/EN 60950-1 Pin Out Specifications Pin 1 2 3 4 5 6 Single + V Input - V Input On/Off Control + V Output -V Output Trim Dual + V Input - V Input On/Off Control + V Output Common - V Output Dimensions 4 1 5 Bottom View 3 6 2.54 (0.10) 5.08 (0.20) 10.16 (0.40) 2.54 (0.10) Diameter 1.00 (0.04) 10.16 (0.40) 25.40 (1.00) 2 10.16 (0.40) 2.54 (0.10) 5.08 (0.20) 5.08 (0.20) 50.80 (2.00) 10.16 (0.40) Single and Dual Output Models Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) Dimensions with Optional Heat Sink 50.8 (2.0) SIDE 25.4 (1.0) 16.3 (0.64) END Notes: Add “-K” suffix for ordering, heat sink is affixed with thermally dissipative adhesive tape. See derating graph for temperature performance. Heat sink material is anodized (black) aluminum, adds weight 11.2g to total mass (42.2g). Thermal impedance of converter is: with heat sink 10℃/W and 12℃/W without heat sink. www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30E-Z 30Watt | DC-DC Converter Derating Free Air Convection 50 ºC Output Power % 100 60 ºC Heatsink 80 60 Safe Operating Area 40 20 0 -40 -25 0 20 40 50 60 75 80 100 Ambient Temperature º C Extended temperature performance can be achieved with optional heat sink. (add suffix “–K” to part number) Trimming Control ON/OFF +V input On/Off Control -V input 4 DC/DC Converter 5 6 7 Positive logic turns on the module during high logic and off during low logic. Module can be controlled by an external switch between the On/Off CTRL terminal and –Vinput terminal. The switch can be either open collector or open drain www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30E-Z 30Watt | DC-DC Converter Recommended Circuits C1 100uF, 100V L 12uH C2 1206, 470pF, 2KV Conducted/Radiated Emissions Dual Output Conducted/Radiated Emissions Single Output L C1 L +V output +V input C1 DC/DC Converter +V output +V input DC/DC Converter Load Load -V output -V input -V input -V output Load Common C2 C2 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.E Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only