AIMTEC AM60U-Z

Series AM60U-Z
60 Watt | DC-DC Converter
FEATURES:








Wide Input 2:1 Range
No Minimum Load Required
Soft Start
Efficiency up to 91%
Adjustable Output Voltage
Remote ON/OFF Function
Operating temperature -40oC to + 85oC
Over Load, Voltage, Temperature & Short Circuit
Protection
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (A)
Isolation
(VDC)
Efficiency
(%)
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
3.3
5
12
15
3.3
5
12
15
14
12
5
4
14
12
5
4
1600
1600
1600
1600
1600
1600
1600
1600
91
91
90
90
91
91
91
91
AM60U-2403SZ
AM60U-2405SZ
AM60U-2412SZ
AM60U-2415SZ
AM60U-4803SZ
AM60U-4805SZ
AM60U-4812SZ
AM60U-4815SZ
Add suffix “-K” for optional heatsink
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
24
48
18-36
36-75
π(Pi) Network
20
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Input reflected ripple current
Under Voltage Lockout (On/Off)
CNTL On / OFF
Maximum
Units
VDC
ms
24
48
~0.7~50
~0.7~100
100
VDC
ms
mA p-p
20
(24V model) 17.8
16
(48V model) 33.5
30.5
ON: 3 ~12Vdc or Open Circuit
OFF: 0 ~ 1.2Vdc or Short pin 2 & 3 (idle current 5mA typical)
VDC
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Case Input & Output
Resistance
Capacitance
Conditions
Typical
3 sec
3 sec
Rated
Units
1600
1600
VDC
VDC
MOhm
pF
>1000
2000
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Over load protection
Short Circuit protection
Short circuit restart
Thermal shutdown
Line voltage regulation
www.aimtec.com
F 051e R12.A
Conditions
Typical
±1
Zener Diode Clamp
135
Continuous
Auto-Restart
120
±0.5
Hiccup
On Case
Tel: +1 514 620 2722
1 of 5
Maximum
Units
%
%
ºC
% of Vin
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM60U-Z
60 Watt | DC-DC Converter
Output Specifications (continued)
Parameters
Load voltage regulation
Temperature coefficient
Ripple & Noise
Conditions
Typical
0% to 100% Full Load
±0.5
±0.02
75
100
±3
250
±10
20MHz Bandwidth (3.3 & 5V)
20MHz Bandwidth (12 & 15V)
Transient Response Deviation
Transient Recovery
Voltage adjustment range
Maximum
Units
%
%/oC
mV p-p
% of Max
µsec
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Conditions
Typical
100% load
With derating above 40 oC
(see graph below)
270
Maximum
KHz
o
-40 to +85
C
o
-40 to +125
110
Above 40 oC
Units
2
Free Air Convection
95
Nickel – coated Copper
70
2.00 x 2.00 x 0.40 inches
50.81 x 50.81 10.14 mm
>110 000 hrs ( MIL-HDBK-217 F at +25 oC)
1.5mm from case for 10 sec
260
C
C
%/ oC
o
% RH
g
o
C
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1:2001 and EN55022:2006 + A1:2007, Class B
Internal EMI Filter designed to meet EN55022 Class A
Pin Out Specifications
Pin
1
2
3
4
5
6
7
8
Single
+V Input
-V Input
On/Off Control
-Sense
+Sense
+V Output
-V Output
Trim
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM60U-Z
60 Watt | DC-DC Converter
Dimensions
4
50.80
(2.00)
1
5
6
3
7
10.16
(0.40)
27.90
(1.10)
2
8
2.54
(0.10)
Printed Face
32.98
(1.30)
Bottom View
5.08
5.08
(0.20) 7.62 (0.20) 7.62
(0.30)
(0.30)
5.08
(0.20)
50.80
(2.00)
2.54
(0.1)
45.72
(1.80)
10.20
(0.40)
Dimensions mm(inch)
Case Tolerance ±0.50 (±0.02)
Pin Pitch Tolerance ±0.35 (±0.014)
6.00
(0.24)
Ø 1.00
(0.04)
Dimensions with Optional Heatsink
Notes: Add “-K” suffix for ordering, heatsink is affixed with thermally dissipative adhesive tape.
See derating graph for temperature performance. Heatsink material is anodized (black) aluminum, adds weight 22g to total
mass (70g). Thermal impedance of converter is: without heatsink 11Ԩ/W and 8.4Ԩ/W with heatsink.
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM60U-Z
60 Watt | DC-DC Converter
Derating
Extended temperature performance can be achieved with optional heatsink. (add suffix “–K” to part number)
Trimming
AM60U-xx03SZ
AM60U-xx05SZ
% Trim
Trim-up
KΩ
Trimdown KΩ
% Trim
Trim-up
KΩ
Trimdown KΩ
1
544.6
315.9
1
244.5
230.6
2
184.0
172.3
2
113.8
106.2
3
103.3
112.5
3
70.6
64.3
4
5
67.7
47.7
79.8
59.2
4
5
49.1
36.3
43.3
30.6
6
34.8
44.9
6
27.7
22.2
7
25.9
34.5
7
21.6
16.2
8
19.3
26.6
8
17.0
11.7
9
14.2
20.4
9
13.4
8.1
10
10.3
15.3
10
10.6
5.3
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM60U-Z
60 Watt | DC-DC Converter
AM60U-xx12SZ
AM60U-xx15SZ
% Trim
Trim-up
KΩ
Trimdown KΩ
% Trim
Trim-up
KΩ
Trimdown KΩ
1
371.4
327.4
1
347.3
433.8
2
183.6
142.1
2
178.5
174.9
3
117.6
83.9
3
115.2
100.9
4
83.9
55.5
4
82.1
65.9
5
63.5
38.6
5
61.7
45.5
6
49.8
27.4
6
47.9
32.1
7
8
39.9
32.5
19.5
13.5
7
8
37.9
30.3
22.6
15.6
9
26.7
8.9
9
24.4
10.2
10
22.1
5.3
10
19.7
5.8
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.A
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only