Series AM60U-Z 60 Watt | DC-DC Converter FEATURES: Wide Input 2:1 Range No Minimum Load Required Soft Start Efficiency up to 91% Adjustable Output Voltage Remote ON/OFF Function Operating temperature -40oC to + 85oC Over Load, Voltage, Temperature & Short Circuit Protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 3.3 5 12 15 3.3 5 12 15 14 12 5 4 14 12 5 4 1600 1600 1600 1600 1600 1600 1600 1600 91 91 90 90 91 91 91 91 AM60U-2403SZ AM60U-2405SZ AM60U-2412SZ AM60U-2415SZ AM60U-4803SZ AM60U-4805SZ AM60U-4812SZ AM60U-4815SZ Add suffix “-K” for optional heatsink NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 24 48 18-36 36-75 π(Pi) Network 20 Filter Start up time Absolute Maximum Rating Peak Input Voltage time Input reflected ripple current Under Voltage Lockout (On/Off) CNTL On / OFF Maximum Units VDC ms 24 48 ~0.7~50 ~0.7~100 100 VDC ms mA p-p 20 (24V model) 17.8 16 (48V model) 33.5 30.5 ON: 3 ~12Vdc or Open Circuit OFF: 0 ~ 1.2Vdc or Short pin 2 & 3 (idle current 5mA typical) VDC VDC Isolation Specifications Parameters Tested I/O voltage Case Input & Output Resistance Capacitance Conditions Typical 3 sec 3 sec Rated Units 1600 1600 VDC VDC MOhm pF >1000 2000 Output Specifications Parameters Voltage accuracy Over voltage protection Over load protection Short Circuit protection Short circuit restart Thermal shutdown Line voltage regulation www.aimtec.com F 051e R12.A Conditions Typical ±1 Zener Diode Clamp 135 Continuous Auto-Restart 120 ±0.5 Hiccup On Case Tel: +1 514 620 2722 1 of 5 Maximum Units % % ºC % of Vin Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM60U-Z 60 Watt | DC-DC Converter Output Specifications (continued) Parameters Load voltage regulation Temperature coefficient Ripple & Noise Conditions Typical 0% to 100% Full Load ±0.5 ±0.02 75 100 ±3 250 ±10 20MHz Bandwidth (3.3 & 5V) 20MHz Bandwidth (12 & 15V) Transient Response Deviation Transient Recovery Voltage adjustment range Maximum Units % %/oC mV p-p % of Max µsec % General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Conditions Typical 100% load With derating above 40 oC (see graph below) 270 Maximum KHz o -40 to +85 C o -40 to +125 110 Above 40 oC Units 2 Free Air Convection 95 Nickel – coated Copper 70 2.00 x 2.00 x 0.40 inches 50.81 x 50.81 10.14 mm >110 000 hrs ( MIL-HDBK-217 F at +25 oC) 1.5mm from case for 10 sec 260 C C %/ oC o % RH g o C Safety Specifications Parameters Standards Designed to meet IEC 60950-1:2001 and EN55022:2006 + A1:2007, Class B Internal EMI Filter designed to meet EN55022 Class A Pin Out Specifications Pin 1 2 3 4 5 6 7 8 Single +V Input -V Input On/Off Control -Sense +Sense +V Output -V Output Trim www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM60U-Z 60 Watt | DC-DC Converter Dimensions 4 50.80 (2.00) 1 5 6 3 7 10.16 (0.40) 27.90 (1.10) 2 8 2.54 (0.10) Printed Face 32.98 (1.30) Bottom View 5.08 5.08 (0.20) 7.62 (0.20) 7.62 (0.30) (0.30) 5.08 (0.20) 50.80 (2.00) 2.54 (0.1) 45.72 (1.80) 10.20 (0.40) Dimensions mm(inch) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) 6.00 (0.24) Ø 1.00 (0.04) Dimensions with Optional Heatsink Notes: Add “-K” suffix for ordering, heatsink is affixed with thermally dissipative adhesive tape. See derating graph for temperature performance. Heatsink material is anodized (black) aluminum, adds weight 22g to total mass (70g). Thermal impedance of converter is: without heatsink 11Ԩ/W and 8.4Ԩ/W with heatsink. www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM60U-Z 60 Watt | DC-DC Converter Derating Extended temperature performance can be achieved with optional heatsink. (add suffix “–K” to part number) Trimming AM60U-xx03SZ AM60U-xx05SZ % Trim Trim-up KΩ Trimdown KΩ % Trim Trim-up KΩ Trimdown KΩ 1 544.6 315.9 1 244.5 230.6 2 184.0 172.3 2 113.8 106.2 3 103.3 112.5 3 70.6 64.3 4 5 67.7 47.7 79.8 59.2 4 5 49.1 36.3 43.3 30.6 6 34.8 44.9 6 27.7 22.2 7 25.9 34.5 7 21.6 16.2 8 19.3 26.6 8 17.0 11.7 9 14.2 20.4 9 13.4 8.1 10 10.3 15.3 10 10.6 5.3 www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM60U-Z 60 Watt | DC-DC Converter AM60U-xx12SZ AM60U-xx15SZ % Trim Trim-up KΩ Trimdown KΩ % Trim Trim-up KΩ Trimdown KΩ 1 371.4 327.4 1 347.3 433.8 2 183.6 142.1 2 178.5 174.9 3 117.6 83.9 3 115.2 100.9 4 83.9 55.5 4 82.1 65.9 5 63.5 38.6 5 61.7 45.5 6 49.8 27.4 6 47.9 32.1 7 8 39.9 32.5 19.5 13.5 7 8 37.9 30.3 22.6 15.6 9 26.7 8.9 9 24.4 10.2 10 22.1 5.3 10 19.7 5.8 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.A Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only