Series AMEPR15D-AZ up to 1A | AC-DC / DC-DC LED driver FEATURES: • • • • • Models Single output Model AMEPR15D-5030AZ+Suffix ② AMEPR15D-4835AZ+Suffix ② AMEPR15D-3650AZ+Suffix ② AMEPR15D-2470AZ+Suffix ② AMEPR15D-15100AZ+Suffix ② ① AC-DC or DC-DC Constant current LED Driver Input range 90-264VAC/47-440Hz High Efficiency up to 83% Operating temperature -20 to 80°C Total Harmonic Distortion < 20% Max Output Power (W) ① 15 15.8 18 16.8 15 Output Voltage Range (V) 36-50 30-48 24-36 12-24 8-15 No Load Output Voltage (V max.) Output Current (A) 62 62 52 34 23 0.3 0.35 0.5 0.7 1 • • • • • Over Temperature Protection IP20 or IP67 Case Active PFC with TRIAC dimmable② SCP, Over Load Protection Leading or Trailing Edge Triac Input Voltage (VAC/Hz) Input Voltage (VDC) Efficiency (%) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 83 83 82 81 80 Exceeding the maximum output power will permanently damage the converter ②Model Nomenclature for Ordering: Add Suffix “-UD” Add Suffix “-UW” Add Suffix “-110D” Add Suffix “-220D” Add Suffix “-110W” Add Suffix “-220W” Universal AC input 90-264VAC(no TRIAC dimming with this option),IP20 Universal AC input 90-264VAC(no TRIAC dimming with this option),IP67 AC input 90-135VAC, IP20 AC input 180-264VAC, IP20 AC input 90-135VAC, IP67 AC input 180-264VAC, IP67 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Inrush current <2ms Leakage current AC current Power Factor External fuse Start up time Output Specifications Parameters Conditions 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC Typical 10 20 0.2 0.25 0.23 0.1 200 Conditions Typical Current accuracy ±5 Line regulation LL-HL ±7 Load regulation 0-100% load ±5 20MHz Bandwidth 1 Ripple & Noise ③ Hold-up time 1 Minimum Load Voltage See the models table ③ Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end. www.aimtec.com F 052.1e R3.H Tel: +1 514 620 2722 1 of 5 Maximum Units A mA A 0.9 0.9 250V/1A Maximum ms Units % % % V p-p ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC / DC-DC LED driver Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance General Specifications Parameters Switching frequency Over load protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Wires Environment Approval Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Maximum Units 3000 Typical 65 110% of Iout 110% of Vout Continuous Auto recovery >105°C -20 to +80 With derating over 55°C Dimensions (L X H X W) MTBF Shock >1000 Conditions Weight Test Typical 3sec -40 to +95 ±0.02 Free air convection Plastic UL1015 20AWG * 10CM IP20 170 IP67 220 133 x 33 x 30mm (5.24 x 1.30 x 1.18 inch) >400,000 hrs (MIL-HDBK-217F at +25°C) VAC MΩ Maximum Units KHz o 100 95 C C o C % / oC o % RH g Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards Standards www.aimtec.com F 052.1e R3.H cULus, CE, FCC EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024 Radiated and Conducted Emission FCC Part 15 Subpart B, Class B, ANSI C63.4 :2003 EMI - Conducted and radiated emission EN 55022 Harmonic Current Emissions IEC/EN 61000-3-2, (EN60555-2) Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Surge Immunity IEC 61000-4-5 RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC / DC-DC LED driver Dimensions Temperature graph Free Air Convection 55 º C Output Power % 100 80 Safe Operating Area 60 40 20 0 - 25 - 20 www.aimtec.com F 052.1e R3.H 0 20 40 60 80 Ambient Temperature º C 100 Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC / DC-DC LED driver Triac Dimming Feature Triac Device LED Lighting Application LED Driver AC Line (Brown) Aimtec Neutral (Blue) Red (+) Black (-) Earth Ground Triac Dimming Notes: A- The triac device can be installed on either Line or Neutral B- Aimtec LED drivers have been designed to function with a wide range of available Triac devices, however the following list of Triac devices have been tested and are recommended by Aimtec. 1) Company: LUTRON Series: SKYLARK Model: SF-10P-WH (input voltage: 120Vac) Model: SF-12P-277-WH (input voltage 277Vac) 2) Company LUTRON Series: DIVA Model: DVF-103P-WH (input voltage: 120Vac) Model: DVF-103P-277-WH (input voltage: 277Vac) 3) Company BERKER Model: 2867 10 (input voltage:230Vac) If the power voltage range is 90~135Vac, triac suggested use model SF-10P-WH or DVF-103P-WH. If the power voltage range is 180~260Vac, triac suggested use model SF-12P-277-WH or DVF-103P-277-WH. www.aimtec.com F 052.1e R3.H Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEPR15D-AZ up to 1A | AC-DC / DC-DC LED driver Triac Dimming Performance AMEPR15D-2470AZ Triac dimming performance is typical as with other models, for specific details on other model performance, please see the Aimtec Triac Dimming Application note at www.aimtec.com NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 052.1e R3.H Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only