Click on Series name for product info on aimtec.com Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter FEATURES: AC-DC Constant Current or Constant Voltage LED Driver Input range 90-305VAC/47-440Hz High Efficiency up to 89% Operating temperature -40 to 80°C Dimmable via resistive 5 Years Limited Warranty Models Single output Max Output Power (W)① Output Voltage Range (V)③ Output Current (A)③ Input Voltage (VAC/Hz) Input Voltage (VDC) AMER150-50300AZ 150 36-50 0-3 90-305/47-440 130-430 AMER150-36420AZ 150 24-36 0-4.16 90-305/47-440 130-430 AMER150-24630AZ 151.2 12-24 0-6.3 90-305/47-440 130-430 Model Over Voltage Protection Over Current Protection Waterproof Case rated IP68 Power Factor Correction Short Circuit Protection Efficiency (%) Mode of Operation Constant Current Constant Voltage② Constant Current Constant Voltage② Constant Current Constant Voltage② 115 230 277 VAC VAC VAC 87 87 86 86 85 85 89 88 88 88 87 87 89 89 88 88 87 87 Add Suffix “-F” No dimming option Exceeding the maximum output power will permanently damage the converter ② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming option in this case. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMER150-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. ① Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current Power factor External fuse Start-up time www.aimtec.com F 052.1e R3.AF Conditions Typical 115 VAC 230 VAC 277 VAC 115 VAC 230 VAC 277 VAC I/O I/FG, O/FG 115 VAC 230 VAC 277 VAC Recommended slow blow type Maximum 2000 1000 900 50 75 90 0.25 3.5 0.98 0.94 0.92 3.5 900 Tel: +1 514 620 2722 1 of 11 Units mA mA mA A A A mA mA A ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Output Specifications Parameters Conditions Typical Maximum Units Current accuracy ±3 % Line regulation LL-HL ±2 % Load regulation 0-100% load ±3 % 200 mV p-p Ripple & Noise ④ Hold-up time (min) 40 ms 100-10 % Current adjustment range⑤ ④Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. ⑤Note: from 0% to 10% dimming adjustment signal instability may be present. Isolation Specifications Parameters Conditions I/O I/FG O/FG Tested voltage Isolation resistance Typical 3sec 500 VDC Maximum Units 3750 2000 500 VAC VAC VAC MΩ >1000 General Specifications Parameters Conditions Typical Switching frequency Maximum 100 Over current protection Over voltage protection Short circuit protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF KHz AMER150-50300AZ AMER150-36420AZ AMER150-24630AZ Refer to Constant Current vs. Constant Voltage Mode curve Auto recovery See derating table Units 3.07 4.27 6.37 A oC -40 to +80 100 oC oC % / oC -40 to +95 ±0.02 Free air convection Non condensing 95 Aluminum Epoxy (IP68 rated) UL1015 18AWG input & 14AWG output *20CM 900 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm >400,000 hrs (MIL-HDBK-217F at +25°C) % RH g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.AF cULus, CE UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13 Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Dimensions Wire connection: Wire Brown Blue Green Red Black Blue (Dimming) White (Dimming) www.aimtec.com F 052.1e R3.AF Connection AC L AC N Ground +V output -V Output + Vs dimming -Vs dimming Tel: +1 514 620 2722 3 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Analog (resistive) Dimming Application Circuit Model Number AMER150-50300AZ AMER150-36420AZ AMER150-24630AZ Maximum Pot Value (kΩ) 19.00 28.00 27.00 0-10V Dimming Application Circuit U1 0-10Vdc +Vs -Vs LTV-817C GND PWM (1KHz) Dimming Application Circuit www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 4 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Derating Efficiency vs. Input Voltage & Output Current (CC mode) AMER150-50300AZ www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 5 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter AMER150-36420AZ AMER150-24630AZ www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 6 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter PFC value vs. Output Load Current (CC mode) AMER150-50300AZ AMER150-36420AZ www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 7 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter AMER150-24630AZ Constant Current vs. Constant Voltage Mode AMER150-50300AZ www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 8 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter AMER150-36420AZ AMER150-24630AZ www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 9 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter Output Current vs. Radj AMER150-50300AZ AMER150-36420AZ www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 10 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER150-AZ up to 6.3A | AC-DC / DC-DC | LED Driver / Converter AMER150-24630AZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.AF Tel: +1 514 620 2722 11 of 11 Toll free: + 1 888 9 AIMTEC (924 6832) North America only