AIMTEC AMSR1

Series AMSR1-78Z
Up to 5 Watt | DC-DC Switching Regulator
FEATURES:
3 Pin SIP package
Non-isolated regulated output
Short circuit protection
Pin-out compatible with LM78XX
Linear Regulators
•
•
•
•
Models
Single output
Model
Input Voltage
(V)
AMSR1-781.5Z
AMSR1-781.8Z
AMSR1-782.5Z
AMSR1-783.3Z
AMSR1-7805Z
4.75-18
4.75-18
4.75-18
4.75-18
6.50-18
Output
Voltage
(V)
•
•
•
•
Output
Current max
(mA)
1.5
1.8
2.5
3.3
5
No heatsink required
Operating temperature -40°C to +85°C
High efficiency Up To 94%
Low ripple and noise
Max
Capacitive
Load (uF)
1000
1000
1000
1000
1000
Efficiency
Vin Max
(%)
220
220
220
220
220
78
82
87
90
94
Efficiency
Vin Min
(%)
72
76
81
85
89
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Absolute Maximum Rating
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Minimum Load Current
Capacitive load
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
www.aimtec.com
F 051e R11.F
Nominal
Typical
Maximum
See the table above
Capacitor
-.0.3~20
Conditions
Vin=(LL-HL) at full load
10-100% load
±0.5
±0.6
±0.02
60
10
20MHz Bandwidth
Conditions
100% load
With derating above +60
VDC
VDC
Typical
±2
Units
Maximum
Units
220
%
%
%/oC
mV p-p
% of Iout max
uF
Maximum
Units
%
Continuous
Auto-Recovery
Typical
330
-40 to +125
KHz
o
C
o
C
o
C
-40 to +85
Free Air Convection
100
95
Non-conductive black plastic (UL94V-0 rated)
2
0.46 x 0.29 x 0.40 inches
11.70 x 7.40 x 10.20 mm
> 4300000 hrs (MIL-HDBK-217F, Ground Benign, t=+25 oC)
1.5 mm from case for 10sec
260
Tel: +1 514 620 2722
1 of 3
% RH
g
o
C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSR1-78Z
Up to 5 Watt | DC-DC Switching Regulator
Pin Out Specifications
Pin
Single
1
2
3
+Vin
GND
+Vout
Dimensions
Front
View
0.46
(11.70)
0.29
(7.50)
0.40
(10.20)
Side
View
0.16
(4.10)
1
2
3
0.02
(0.5)
0.02
(0.5)
Bottom
View
0.01
(0.25)
0.080 (2.00)
0 .13
(3.30)
0.1
0.1
(2.54) (2.54)
0.13
(3.30)
Derating
Free Air Convection
60 ºC
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R11.F
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMSR1-78Z
Up to 5 Watt | DC-DC Switching Regulator
Application Circuits
Recommended soft start circuit
+ Vout
+Vin
AMSR1-78Z
C1
C2
1mS
( Minimum)
GND
GND
- up use “soft start” Vin and C1 = 47 uF
To protect converter during power
C 2 = 10 uF ( optional )
Wide input isolated (up to 6000VDC) dual outputs with high efficiency
+Vin
AMSR1-78Z
C1
C2
DC
DC
+Vout
COM
-Vout
GND
Isolated Dual Outputs
Wide Input Range 6.5V to 18V
C1: Optional
C2: Required for Decoupling (further decoupling may be required
between the two converters).
Isolated (up to 6000VDC) single and regulated output
+Vin
DC
DC
C1
AMSR1-78Z
+Vout
C2
-Vout
GND
Isolated Single Output
Wide Input Range 6.5V to 18V
Point of Load Architecture
Improved Line/Load Regulation
C1: Required for Decoupling (further decoupling may be required
between the two converters).
C2: Optional
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R11.F
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only