FUJI EDS2-24A

SHEATH TYPE PLATINUM RESISTANCE THERMOMETER BULB
DATA SHEET
FTH
This resistance thermometer bulb is firmly sealed with highpurity oxidized magnesium (insulating material) in a fine metallic protective tube. Unlike ordinary resistance thermometer bulbs, it provides excellent sensitivity and vibration resistance, and is designed to permit easy bending work.
FEATURES
SPECIFICATIONS
• Applied standard:
JIS C 1604 -1997
• Resistance element:
Nominal resistance; Pt100
Class; A, B
Rated current; 2mA
Allowable error due to temperature;
Class
Allowable error
A
±(0.15+0.002t)˚C
B
±(0.3+0.005t)˚C
Note:1) "t" is measured temperature expressed in (˚C) independent of +/–
symbols.
2) Allowable error is the maximum
limit of resistance value of resistance thermometer bulb obtained
by subtracting measured temperature from the temperature calculated according to the reference
resistance table.
• Protective tube material:
SUS316
• Sheath outside diameter:
φ4.8mm or φ6.4mm
• Mounting method:
Insertion type or screw-in type (with
mounting fitting)
Mounting fitting screw size; R1/8(PT1/8) or
R1/4(PT1/4)
• Insertion length:
100 to 9000mm(specified in the unit of
10mm)
• Terminal structure:
Extension cable type, connector type,
exposed terminal type, extension cable
(with connector) type
• Operating temperature range:
–200 to +500˚C
• Element structure:
Single-core, 3-wire system
• Minimum bending radius:
5 times the sheath outside diameter,
not bent up to 100mm from tip
• Response characteristic:
See next page.
Code symbols
F TH
W
Description
5 -
Element
Single-core, 3-wire system
(JPt100. class B)
Single-core, 3-wire system
(JPt100, class A)
1
7
Sheath outside diameter
φ4.8mm
φ6.4mm
3
4
Sheath material
SUS316
W
Mounting method
Insertion type
With mounting fitting R1/8(PT1/8)
With mounting fitting R1/4(PT1/4)
0
1
2
Insertion length
Enter insertion length in cm unit
(minimum length; 10cm, maximum
length; 900cm).
Example: 055 / 55cm
0 1 0
∼
1. Resistance thermometer bulb is very small in size, providing excellent sensitivity.
2. Adoption of integrated structure has improved the vibration resisting characteristic.
3. Easy bending work allows fabricating a long-sized resistance thermometer bulb for easy measurement even in a
place where ordinary type resistance thermometer bulb
cannot be used.
4. Various types of terminals such as extension cable type,
connector type, exposed type, terminal box type, etc., are
also available for selection according to applications.
5. Measurement range covers –200 to +500˚C.
9 0 0
Terminal structure
Extension cable type
Exposed terminal type
Terminal box type
Connector type
Extension cable(with connector)type
L
D
G
P
Q
0
1
3
Cable length
None (12th code D, G, P)
With 1m cable
With 3m cable (12th code L, Q)
EDS2-24a
Date
Jun. 14, 2002
FTH
< Resistance bulb time-lag >
55
L (as specified)
90
Mounting fitting shown at
lower left is supplied as
specified.
φ4.8 sheath type
80
φ6.4 sheath type
0
FTH 1 3 W 1 5
7 4
2
70
D0
Ordinary type, φ12 SUS304
protective tube
50
74
L (as specified)
Mounting fitting shown
at lower left is supplied
as specified.
G3/8 (PF3/8)
30
20
ø7.5
0
FTH 1 3 W 1 5
7 4
2
10
0
1
2
T=15sec
G0
3
T=1min10sec
70
Time lapse (min)
L (as specified)
ø8
0
ø4.8 or ø6.4
(as specified)
40
(82)
Temperature (˚C)
63.2
60
ø4.8 or ø6.4
(as specified)
50
100
Resistance thermometer bulb time-lag largely varies with
measurement conditions. The above shows an example of
measurement in 100°C warm water with sheath type
resistance thermometer bulb and ordinary type resistance
thermometer bulb.
ø4.8 or ø6.4
(as specified)
Note: "T" :Time constant
ø17
T=8sec
Connector
0
FTH 1 3 W 1 5
7 4
2
P0
Outline diagram (Unit: mm):
L (as specified)
40
Cabtyre cable
PVC cabtyre cable
Mounting fitting (supplied as specified)
R1/8 (PT1/8) or R1/4 (PT1/4)
0
FTH 1 3 W 1 5
7 4
2
ø10
ø8
L (as specified)
H (as specified)
70
ø6.5
ø17
40
ø4.8 or ø6.4
(as specified)
1000
ø10
ø6.5
ø4.8 or ø6.4
(as specified)
ø4.3 hole
Connector
0
FTH 1 3 W 1 5
7 4
2
Q 1
3
L1
3
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
Instrumentation Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.