FUJI EDS2-9B

SHEATH TYPE THERMOCOUPLE
DATA SHEET
FTJ, K, E
This thermocouple is firmly sealed with high-purity oxidized
magnesium (insulating material) in a fine metallic protective
tube without air gaps, together with the thermocouple element.
Unlike ordinary type thermocouples, it provides excellent
sensitivity and vibration resistance, and is designed to permit easy bending work.
FEATURES
1. Thermocouple tube is very small in size, providing excellent sensitivity.
2. Adoption of integrated structure has improved the vibration resisting characteristic.
3. Easy bending work allows fabricating a long-sized thermocouple for easy measurement even in a place where ordinary type thermocouples cannot be used.
4. Thermocouple strand is not exposed to air, ensuring a
long life with minimum deterioration or breaks of wire,
unlike ordinary type thermocouples.
5. A variety of protective tube materials are available for selection according to applications.
6. Various types of terminals such as extension cable type,
connector type, exposed type, terminal box type, etc., are
also available for selection according to applications.
Class :
Class
Class 3 is permitted only
for FTK, FTE.
2
3
Note: Class 3 is applied only for low
temperature of less than 40˚C.
Temperature tolerance :
Symbol Class
SPECIFICATIONS
1
• Applied standard:
JIS C 1605-1995
• Thermocouple element:
Component material
K
J
K
E
+ foot
Iron
2
3
Component material
Kind
- foot
Alloy made
of copper
and nickel
Alloy made
of nickel
and chrome
Alloy made
of nickel
Alloy made
of nickel
and chrome
Alloy made
of copper
and nickel
(Note) "+foot " is connected to theterminal (+)
of instrument for measuring thermal
electromotive force, and ''- foot '' is
connected to opposite side.
Remarks
1
1
E
2
3
1
J
2
Measured
temperature
(˚C)
-40˚C or more, less than +375˚C
±1.5˚C
375˚C or more, less than 1000˚C
±0.004•|t|
-40˚C or more, less than +333˚C
±2.5˚C
333˚C or more, less than 1200˚C
±0.0075•|t|
-167˚C or more, less than +40˚C
±2.5˚C
Tolerance
-200˚C or more, less than -167˚C
±0.015•|t|
-40˚C or more, less than +375˚C
±1.5˚C
375˚C or more, less than 800˚C
±0.004•|t|
-40˚C or more, less than +333˚C
±2.5˚C
333˚C or more, less than 900˚C
±0.0075•|t|
-167˚C or more, less than +40˚C
±2.5˚C
-200˚C or more, less than -167˚C
±0.015•|t|
-40˚C or more, less than +375˚C
±1.5˚C
375˚C or more, less than 750˚C
±0.004•|t|
-40˚C or more, less than +333˚C
±2.5˚C
333˚C or more, less than 750˚C
±0.0075•|t|
Note: Tolerance means the maximum allowable limit of
the value calculated by subtracting the
temperature of the temperature measuring
junction from the temperature obtained by
converting the thermal electromotive force by the
reference thermal electromotive force.
|t| is the value indicated by temperature (˚C) that
is not related to + or - symbol of the measured
temperature.
EDS2-9b
Date
Jun. 6, 2006
FTJ, K, E
• Sheath material :
SUS347, SUS310S, SUS316 or Inconel
• Sheath outside diameter :
φ1.6, φ3.2, φ4.8 or φ6.4mm
• Mounting method :
Insertion type or screw-in type (with
mounting bracket)
Mounting screw size: R1 /8 (PT1 /8)or R1 /4
(PT1 /4)
• Insertion length :
100~9000mm (specified in 10mm base)
• Terminal structure :
Extension cable type, connector type, exposed type, terminal box type, and extension cable (with connector) type
• Temperature limit :
(Unit:˚C)
Sheath outside
diameter (mm)
Sheath
Kind material(*)
1.6
A
3.2
B
A
650
K
4.8
B
A
6.4
B
A
B
800 900 800 1000
750
E
650
–
750
–
800
–
800
–
J
450
–
650
–
750
–
750
–
(Note*) Sheath material
• Element structure :
Single-core: insulation type,
Twin-core: insulation type
Single-core; grounding type,
Twin-core: grounding type
(Note) Twin-core type : φ3.2mm or more
• Minimum bending radius :
5 times larger than sheath outside diameter
•Response characteristic :
See table below.
A: SUS347, SUS310S, SUS316
B: Inconel
Sheath thermocouple response characteristic
100
80
φ6.4mm
Response (%)
φ4.8mm
60
φ3.2mm
φ1.6mm
40
Type of
thermocouple
20
Sheath
thermocouple
(Grounding type: 20 to 100˚C in water)
0
0
2
4
6
8
Time (sec)
2
10
12
14
Ordinary
type
Time
constant (sec)
φ6.4
2.60
φ4.8
1.22
φ3.2
0.53
φ1.6
0.11
φ12
51
Code symbols
1 2 3 4 5 6 7 8
Sheath type J thermocouple F T J
4 -
Sheath type K thermocouple F T K
4 -
Sheath type E thermocouple F T E
4 -
9 10 11 12 13
Description
Element
Single-core
Twin-core
Single-core
Twin-core
Single-core
Twin-core
Single-core
Twin-core
Single-core
Twin-core
1
2
3
4
5
6
7
8
A
B
: insulation type,
: insulation type,
: grounding type,
: grounding type,
: insulation type,
: insulation type,
: grounding type,
: grounding type,
: insulation type,
: insulation type,
class 2
class 2
class 2
class 2
class 3
class 3
class 3
class 3
class 1
class 1
FTJ cannot be used.
Sheath outside diameter (mm)
φ1.6
φ3.2
φ4.8
φ6.4
1
2
3
4
Sheath material
SUS316
SUS347
SUS310S
Inconel
(Note) Combination of 4th, 5th and 6th codes is possible
but is limited as shown in the following table.
: Single-core element only
: Single-core and twin-core
W
L
R
X
External
Type Material
size
FTJ
SUS316
FTK
SUS310S
SUS316
SUS347
Inconel
FTE
SUS347
SUS316
φ1.6
φ3.2
φ4.8
φ6.4
Mounting method
Without mounting fitting
With mounting fitting R1/8 (PT1/8); sheath outside diameter φ6.4cannot be used.
With mounting fitting R1/4 (PT1/4)
0
1
2
Insertion length
Enter insertion length in the unit of ''cm''.
Example) 200mm / 020
1500mm / 150
Minimum length: 10cm, Maximum length: 900cm
Structure
Extension cable type
Exposed terminal type
Terminal box type
Connector type
Extension cable (with connector) type
L
D
G
P
Q
0
1
3
Z
Cable length
None (12th code: D, G, P)
1m cable
3m cable (12th code: L, Q)
Other
3
FTJ, K, E
Outline diagram (Unit: mm)
( Insertion diameter "d" can be selected from 1.6 , 3.2 , 4.8 , 6.4.)
74
L (as specified)
(82)
ød
ø4.3 hole
2×4
L (as specified)
Sheath thermocouple
ø8
40
ød
1000
Compensation lead wire
J
FT K
E
16
27
38
4A
5B
1
2
3
4
W
L
R
X
J
FT K
E
ø7.5
Sheath thermocouple
0
1 4
2
G3/8 (PF3/8)
16
27
38
4A
5B
1
2
3
4
W
L
R
X
0
1 4
2
G0
L 1
3
L (as specified)
ø6
L (as specified)
Sheath thermocouple
ød
54
43
Connector
J
FT K
E
Sheath thermocouple
J
FT K
E
16
27
38
4A
5B
1
2
3
4
W
L
R
X
0
1 4
2
ø17
ød
70
16
27
38
4A
5B
1
2
3
4
W
L
R
X
0
1 4
2
P0
D0
Compensation lead wire
L (as specified)
2×4
ø8
ød
40
H (as specified)
Sheath thermocouple
ø6
ø17
70
Connector
Connection diagram
J
FT K
E
Mounting fitting
(Supplied as specified)
16
27
38
4A
5B
1
2
3
4
W
L
R
X
0
1 4
2
Q 1
3
A(+)
B(-)
R1/8 (PT1/8) or R1/4 (PT1/4)
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
Instrumentation Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan