XFGM Data sheet Pre-amplified/5V Excitation/Gauge ■Features On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Surface mount package ■Ordering Information XFGM-6 025KP G SR Terminal leads configuration Model Surface mount package Length of the pressure port 3:3mm 6:6mm Measurable pressure range(kPa) -100 to 100 0 to -100 0 to 25 0 to 50 0 to 100 0 to 200 0 to 1000 Pressure type G:Gauge(Positive pressure) GV:Gauge Pressure(Negative pressure) GW:Gauge Pressure(Positive/Negative pressure) Rated Pressure KP:kPa MP:MPa Weight (grams) Weight (grams) 0.3 0.35 Part number 3mm pressure port 6mm pressure port XFGM-3100KPGWSR XFGM-6100KPGWSR XFGM-3100KPGVSR XFGM-6100KPGVSR XFGM-3025KPGSR XFGM-6025KPGSR XFGM-3050KPGSR XFGM-6050KPGSR XFGM-3100KPGSR XFGM-6100KPGSR XFGM-3200KPGSR XFGM-6200KPGSR XFGM-3001MPGSR XFGM-6001MPGSR RoHS compliance ■Specifications 100KPGW Model Recommended operating conditions Pressure type Rated pressure Measurable pressure range Temperature range Pressure media Supply voltage(constant) +/-100 -100 to100 100KPGV -100 0 to -100 025KPG 050KPG 100KPG 200KPG Gauge pressure 50 100 200 0 to 50 0 to 100 0 to 200 0 to 85 Non-corrosive gases only (No liquid) 5+/-0.25 25 0 to 25 Absolute maximum rating Maximum load pressure Twice of rated pressure 8 -40 to 125 -40 to 125 30 to 80 (Non dew condition) Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25deg.C) Power consumption 10mA max. Output impedance 10Ω max. Source current 0.2mA max. Sink current 2mA max. Response time 2 (for the reference) Output span voltage 4.5 Offset voltage *1 *2 *3 0.2+/-0.1125 (at 0 kPa ) Output voltage at full scale *1 *4 *5 4.7+/-0.1125 (at rated pressure) Accuracy *1 +/-2.5 Maximum excitation voltage Operating temperature Storage temperature Operating humidity *1 Excluding input voltage error. *2 0.2+/-0.1125V(at -100kPa ) *4 4.7+/-0.1125V(at +100kPa) 0-85deg.C *3 0.2+/-0.1125V(at 0kPa) *5 4.7+/-0.1125V(at -100kPa) 1 001MPG 1000 0 to 1000 1.5 times of rating pressure Unit kPa kPa deg.C VDC VDC deg.C deg.C %RH mA Ω mA mA msec. V V V %FS/0-85deg.C XFGM Data sheet Pre-amplified/5V Excitation/Gauge ■Outline dimensions■ 2-φ1.1 2 XFGM Data sheet Pre-amplified/5V Excitation/Gauge ■Connection diagram■ View from Lavel Marking ■Transfer Function■ Vout = Vs×( P×α+β) ± (Pressure Error×Temperature Error Multiplier×α×Vs) Vs=Vcc=5.0V P=Input pressure(kPa) Model XFGM-3100KPGWSR XFGM-3100KPGVSR XFGM-3025KPGSR XFGM-3050KPGSR XFGM-3100KPGSR XFGM-3200KPGSR XFGM-3001MPGSR XFGM-6100KPGWSR XFGM-6100KPGVSR XFGM-6025KPGSR XFGM-6050KPGSR XFGM-6100KPGSR XFGM-6200KPGSR XFGM-6001MPGSR Measurable pressure range(kPa) -100 to 100 0 to -100 0 to 25 0 to 50 0 to 100 0 to 200 0 to 1000 Temperature Error Multiplier 3 α β Pressure Error (kPa) 0.0045 -0.009 0.036 0.018 0.009 0.0045 0.0009 0.49 0.04 0.04 0.04 0.04 0.04 0.04 5 2.5 0.625 1.25 2.5 5 25 XFGM Data sheet Pre-amplified/5V Excitation/Gauge ■Output characteristics■ XFGM-3100KPGVSR XFGM-3025KPGSR XFGM-3050KPGSR XFGM-3100KPGSR XFGM-3200KPGSR XFGM-3001MPGSR XFGM-6100KPGVSR XFGM-6025KPGSR XFGM-6050KPGSR XFGM-6100KPGSR XFGM-6200KPGSR XFGM-6001MPGSR ↑Output voltage(mV) Output voltage at full scale 4.7V Output span voltage Offset voltage 0.2V Rated pressure 0kPa Atomospheric pressure XFGM-3100KPGWSR →Pressure(kPa) ↑Output voltage(mV) XFGM-6100KPGWSR Output voltage at full scale 4.7V Output span voltage Offset voltage 0.2V -100kPa 0kPa Atomospheric pressure Note ; +100kPa →Pressure(kPa) Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag. If the sensors expose to an atmosphere, the pins will be black by sulfuration. Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress such as mounting, installation and etc. over longtime using. 4 XFGM Data sheet Pre-amplified/5V Excitation/Gauge Reflow Soldering process recommendation profile Package Surface Temperature (Degree C) 230 210 150 Room Temp. Time a a: Rump up rate b: Pre-heating c: Rump up rate d: Heating e: Rump down rate Note ; b c d e 1 or 2 deg.C/sec. 150 to 180 deg.C,within 60 to120sec. 1 to 2 deg.C/sec. max.230 deg.C,max.10sec. 210 deg.C,within 30sec. 1 or 2 deg.C/sec. 1 ) Temperature means Surface temperature of the sensor package. 2 ) Reflow process max. 2 times. 3 ) Do not wash the sensor. 4 ) Do not put the solder and flux on the sensor package. If you have any questions regarding technical issues or specifications, please contact us. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected] 5