HONEYWELL-ACC 2C206

Manual Switches
Pushbutton Switches and Indicators
Series 2
BARRIER MOUNT
Display screen
(page 115)
Housing
(next page)
Mounting barrier
(next page)
FEATURES
1 Easy-to-assemble modules provide
thousands of display/control
combinations
1 Up to 4 incandescent lamps
1 1, 2, 3, or 4-section display
1 Transmitted or projected color
1 Integral hold-in coil option provides
remote released contacts. Pull-in coils
(flange mount only) enable remote
actuation
1 Switch guard accessory.
CHANGE LAMPS OR FILTERS
FROM PANEL FRONT
Switch unit
(page 114)
Mounting barriers attach to either the long
or short sides of the housing. They have
spring clips which grip the panel. Mounting barriers also separate display screens
to protect against inadvertent operation.
Multiple units can be attached together in
a strip and snapped into a panel slot; or
they can be mounted individually.
FLANGE MOUNT
Display screen
(page 115)
Housing
(page 113)
Without tool. Remove display screen/
lampholder assembly from 2C200 operator-indicator (or 2F200 indicator). Unit is
keyed to maintain proper orientation
when replacing. Use only flange base
T-13⁄4 lamps with 2C200 and 2F200 devices.
LAMPS AND FILTERS
Order lamps and filters for projected color
from page 111.
Flange mount units have mounting clips
ready-attached to the housing. They can
be individually installed or replaced; and
Pushbuttons
Switch
unit
(page 114)
enable use of an overlay panel, if desired.
Groupings can be separated by optional
spacing barriers.
MODULES ASSEMBLE EASILY
All modules are ordered as separate
items which snap together for easy assembly.
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
105
Manual Switches
Pushbuttons Switches and Indicators
Series 2
BARRIER MOUNT MODULES
Barrier mount assemblies are identical in
panel appearance. Operator-indicator
housings have spring clips for attaching
switch modules. This feature is not provided with indicator housings.
Barriers are necessary for mounting.
They can be specified for attachment to
the long or short side of the housing, as
stated in the order guides.
BARRIER MOUNT HOUSING ORDER GUIDE
See ‘‘Application Data’’ for typical bailing circuits for coil-equipped modules.
Barriers
Attach On:
Barriers on long sides
No. of
Lamp Sockets
Tool Not Required
Operator-Indicator
Indicator Only
Long Sides
of Housing
2 (A & C)
4 (A-D)
2C207
2C209
Short Sides
of Housing
2 (A & C)
4 (A-D)
2C201
2C203
2F203
MOUNTING BARRIER ORDER GUIDE
For strip mounting, specify one more barrier than the number of units in the group.
Mounting Barrier
Type
For Panel
Thickness
Catalog Listings
Gray
Black
Attach to
Long Sides
.06-.19 in. (1,52-4,83 mm)
2B2
2B4
Attach to
Short Sides
.06-.19 in. (1,52-4,83 mm)
2B1
2B3
Note: Panels .19 in. (1,52 mm) thick require the .06-.19 in. (1,52-4,83 mm) type barriers.
Barriers on short sides
106
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Manual Switches
Pushbutton Switches and Indicators
Series 2
FLANGE MOUNT MODULES
Flange mount assemblies are identical in
panel appearance. Operator-indicator
housings have spring clips for switch
modules attachment (not provided with
indicator housings).
Barriers are not required, since the panel
mounting clips are ready-attached to
flange sides of the housings. However,
spacing barriers can be used for colorcoding. They also aid in preventing inadvertent operation of two screens with one
push.
Mounting dimensions on page 114.
Flanges on long sides
FLANGE MOUNT HOUSING ORDER GUIDE
See ‘‘Application Data’’ for typical bailing circuits for coil-equipped modules.
Flanges On:
Long Sides of
Housing
No. of Lamp
Sockets
2 (A & C)
4 (A-D)
Tool Not Required
OperatorIndicator
Indicator Only
2C204
2C206
2F206
SPACING BARRIER ORDER GUIDE
For .06-31 in. (1,5-7,9 mm) thick panels.
Spacing Barrier
Type
For Long Flange Housing
Catalog Listings
Gray
Black
2B9
2B18
Pushbuttons
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
107
Manual Switches
Pushbutton Switches and Indicators
SWITCH MODULES
Series 2
Interchangeable type 2D switch modules
attach to spring clips on the bottom of
operator-indicator housings. There is a
wide selection of circuitry, electrical ratings, operating actions and terminations.
For mounting dimensions, see page 115.
SM SUBMINIATURE MULTI-SPDT SWITCH MODULES
Momentary action
SM switch modules offer a choice of two
momentary action styles, one with a pronounced touch-feedback, the other with
low operating force for rapid repeat ac-
Alternate action
tuation. Also available with alternateaction and combination momentary/
alternate action modules. Extra length
turret solder terminals.
ELECTRICAL RATING
Silver contacts:
30 VDC: 5 amps res. sea level or 50,000 ft,
3 amps ind. sea level, 2.5 amps 50,000 ft.
Max. inrush, 24 amps.
UL and CSA rating for basic switch: 5
amps, 125 or 250 VAC.
Gold contacts:
30 VDC: 0.5 amp ind., 1 amp res., sea level
and 50,000 ft. Max. inrush, 2 amps.
SM SWITCH MODULE ORDER GUIDE
No. of
SPDT Circuits
Momentary Action
Touch-Feedback Type
Silver Contacts
Alternate Action
Low Force Type
Silver Contacts
1
2
4
2D100
2D2
2D9
2D118
2D26
2D33
V3 COMPACT SPDT/DPDT SWITCH MODULES
ELECTRICAL RATING
30 VDC: 10 amps ind.* sea level, 6 amps
ind.,* 50,000 ft. Motor load, 6 amps.** UL
and CSA rating for basic switch: 10 amps,
1⁄3 Hp, 125 or 250 VAC; 1⁄2 amp, 125 VDC;
1⁄4 amp, 250 VDC.
* Inductive currents in accordance with AN3179.
** Motor load rating based on starting current.
V3 SWITCH MODULE ORDER GUIDE
No. of SPDT
Circuits
Momentary Action
1
2D70
2
2D72
V3 switch modules have screw terminals
with lockwashers. Quick-connect terminals (not shown) are also available. When
used with short-flange operator indicators, add spacing barriers to prevent
interference.
108
Honeywell 1 H Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Manual Switches
Pushbutton Switches and Indicators
Series 2
SINGLE-SECTION/
ONE-PIECE SCREENS ORDER GUIDE
ONE-PIECE DISPLAY
SCREEN OPTIONS
Single-section
These translucent solid color display
screens are single-section/one piece
construction
Colors
Standard
Red
2A1
Yellow
2A2
Green
2A3
White
2A5
THREE-PIECE DISPLAY
SCREEN OPTIONS
Single-section
These screens have transparent colored
or colorless caps, transparent colorless
legend inserts and translucent colored
bases.
SINGLE-SECTION/THREE-PIECE
SCREENS ORDER GUIDE
Color
Colorless
Caps
Red
2A81
Yellow
2A82
Green
2A85
White
2A70
Amber
2A114
NOTE:
Add –L to catalog listing if button is to be
legended.
Pushbuttons
Silicone rubber baffles prevent light spillage
from one section to another. Screen caps and
legend inserts are transparent colorless. Bases
are translucent colored.
For more information on 2, 3, and 4-section
display screens, contact the MICRO SWITCH
Application Center.
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
109
Manual Switches
Pushbutton Switches and Indicators
110
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Series 2
Manual Switches
Pushbutton Switches and Indicators
LEGEND INFORMATION
Honeywell MICRO SWITCH Division provides legend service on the inserts supplied with three-piece screens only. To
specify your needs, add -L to the catalog
listings (example: 2A81-L) and use Legend Order Sheet (Form FO-62308),
shown on facing page. Reproduce it on
your office copier.
On any one insert, only one size of type is
provided in either black or white. After
legending, the insert is assembled to the
display screen. The type face used is
‘‘Modified Gothic’’.
Series 2
SCREEN/LEGEND COLORS
The chart below shows recommended
display screen and legend color combinations for optimum legibility.
Legend Lettering
Screen
Color
Black
White
Red
x
Green
x
Yellow
x
Amber
x
White
x
x
LAMPS
T-13⁄4 incandescent lamps are available
from MICRO SWITCH in 28 volt versions.
Use of neon lamps is not recommended.
Light output is approximately 30% of an
incandescent lamp. Also, a neon lamp
will not illuminate blue or green filters or
display screens due to the absence of
these colors from the neon light spectrum.
LAMP ORDER GUIDE
Rating
Catalog
Listing
Base
Style
2E1
Flange
Type
No.
327
Life/Voltage†
Volts
Amps
Life in
Hours
28
.040
1000
Volts
Expected
Life (Hrs.)
24.0
26.0
30.0
7,500
2,800
400
LAMP POLICY
The 28 volt lamps are offered as a convenience to customers. Honeywell MICRO
SWITCH Division does not extend any
warranty as to such lamps, and cannot
guarantee to provide lamps from specific
manufacturers. Any technical or quality
questions regarding such lamps should
be directed to the lamp manufacturer.
† These are experimental continuous life test results supplied by a lamp manufacturer for reference only.
Intermittent operation may reduce these figures as much as 50%. Ratings are based on median values of
current and life.
COLOR FILTERS FOR PROJECTED
COLOR
Projected color is achieved by using
white buttons and color filters over clear
lamps. When lamps are lighted, white
button takes on color projected by the
filters.
FILTER ORDER GUIDE
Wattage should not exceed 2.4 watts (2 lamps) per switch, for continuous illumination.
Red
Green
Amber
White*
2G12
2G14
2G16
2G17
* Has blue tint to compensate for high yellow content of incandescent lamps at low voltages.
Filters used with type 2C200 and 2F200
housings (no-tool relamping) slip over
lamp sockets in lampholder.
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
111
Pushbuttons
Filter Style
For Type 2C200 and
2F200 Housings
Manual Switches
Pushbutton Switches and Indicators
SWITCH GUARD ACCESSORY
A hinged cover on the switch guard helps
avoid inadvertent operation of the display
screen. It is installed in place of the transparent slide-on cap furnished with threepiece screen. Note: When used with pullin coil devices, specify the 2C200 operator-indicator housings which have the
no-tool relamping feature.
Key:
0,0 = mm
0.00 = inches
Barrier mount assembly with guard installed. (Can also be used with all flange
mount units.)
Guard requires a ‘‘lift-to-push’’ response
to operate switch normally.
Order Catalog Listing
112
2H20
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Series 2
Manual Switches
Pushbutton Switches and Indicators
Series 2
MOUNTING DIMENSIONS (For reference only)
Long barrier operator-indicators
Short barrier operator-indicators
Short barrier indicators
Long barrier indicators
Mounting barriers
Long
Key:
0,0 = mm
0.00 = inches.
A
Panel Thickness
1,5/.06
4,6/.18
1,5-4,81/.06-.19
4,8-7,9/.19-.31
Length Of Panel Cutout*
Type of Indicator or
Operator-Indicator
Number of Units
1
2
3
4
5
6
7
Short
Barrier
mm
36,09
68,00
99,87
131,72
163,60
195,48
227,36
in.
1.421
2.677
3.932
5.186
6.441
7.696
8.951
Long
Barrier
mm
30,00
55,78
81,58
106,34
133,12
159,90
184,68
in.
1.181
2.196
3.212
4.226
5.241
6.256
7.271
* Nominal dimensions, ±0,25 mm/0.10 in. (In 5% of
the cases, the cutout will be undersized for the buildup of assembled units and will require enlargement.
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
113
Pushbuttons
Short
Manual Switches
Pushbutton Switches and Indicators
Series 2
MOUNTING DIMENSIONS (For reference only)
Long flange
operator-indicators
Long flange indicators
Spacing barriers
Short
Long
Key:
0,0 = mm
0.00 = inches.
Length Of Panel Cutout*
Add 4,19 mm/.165 in. to length for each optional spacing barrier used.
Type of Indicator or
Operator-Indicator
Long
Flange
Number of Units
1
2
3
4
5
6
7
mm
27,94
55,75
83,57
111,36
139,17
166,98
194,77
in.
1.1
2.195
3.290
4.384
5.479
6.574
7.668
* Nominal dimensions, ±0,25 mm/0.10 in. (In 5% of
the cases, the cutout will be undersized for the
build-up of assembled units and will require
enlargement.
114
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
Manual Switches
Pushbutton Switches and Indicators
Series 2
MOUNTING DIMENSIONS (For reference only)
SM Switch Modules
V3 Switch Modules
Pushbuttons
Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
115