DATASHEET 56V MODULE FEATURES AND BENEFITS TYPICAL APPLICATIONS Standard rackmount configurations Up to 10KW in half rack, 4U module UL registered component Datacenter UPS Hospital UPS Industrial Process Equipment Backup Power for graceful shutdown Transition power for motorgenerator set or fuel cells PRODUCT SPECIFICATIONS ELECTRICAL Rated Capacitance BMOD0130 P056 B03 130 F 1 Minimum Capacitance, initial Maximum ESR DC, initial 130 F 1 8.1 mΩ 1 Rated Voltage Absolute Maximum Voltage 56 V 62 V 14 Maximum Continuous Current (ΔT = 15 C) o 61 A 2 Maximum Continuous Current (ΔT = 40oC)2 99 A Maximum Peak Current, 1 second (non repetitive) 1,800 A Standby Current, maximum (Passive Balancing)4 120 mA 3 Maximum Series Voltage 750 V TEMPERATURE Operating Temperature (Ambient temperature) Minimum -40oC Maximum 40oC Storage Temperature (Stored uncharged) Minimum -40oC Maximum 70oC Page 1 Document number: 1017119.2 maxwell.com DATASHEET 56V MODULE PRODUCT SPECIFICATIONS (Cont’d) PHYSICAL BMOD0130 Mass, typical 18 kg Power Terminals M8/M10 Recommended Torque - Terminal 20/30 Nm Telcordia GR-63-CORE Zone 4 Vibration Specification Shock Specification - Environmental Protection IP30 Cooling Natural Convection MONITORING / CELL VOLTAGE MANAGEMENT Internal Temperature Sensor N/A Temperature Interface N/A Cell Voltage Monitoring Overvoltage Alarm Connector Deutsch DTM Cell Voltage Management Passive POWER & ENERGY Usable Specific Power, Pd5 Impedance Match Specific Power, Pmax 2,600 W/kg 5,400 W/kg 6 Specific Energy, Emax7 Stored Energy 3.1 Wh/kg 56.6 Wh 8 LIFE High Temperature1 8 years Capacitance Change 20% ESR Change 100% (at Rated Voltage & Maximum Operating Temperature) (% decrease from minimum initial value) (% increase from maximum initial value) Room Temperature1 14 years Capacitance Change 20% ESR Change 100% (at Rated Voltage & 25oC) (% decrease from minimum initial value) (% increase from maximum initial value) Page 2 Document number: 1017119.2 maxwell.com DATASHEET 56V MODULE PRODUCT SPECIFICATIONS (Cont’d) BMOD0130 Cycle Life1,9 1,000,000 cycles Capacitance Change 20% ESR Change 100% Test Current 100 A (% decrease from minimum initial value) (% increase from maximum initial value) Shelf Life 1,10 2 years (Stored uncharged up to a maximum storage temperature) SAFETY Short Circuit Current, typical 6,900 A (Current possible with short circuit from rated voltage. Do not use as an operating current.) Factory High-Pot Test13 3,500 V DC RoHS UL810a (750 V) Certifications TYPICAL CHARACTERISTICS THERMAL CHARACTERISTICS Thermal Resistance N/A Thermal Resistance 0.50oC/W (Rma, Module Case to Ambient), typical (Rca, All Cell Cases to Ambient), typical Thermal Capacitance (Cth), typical 2 16,460 J/oC ESR AND CAPACITANCE VS TEMPERATURE 180% Capacitance DC ESR Percentage change from value at 25°C 170% 160% 150% 140% 130% 120% 110% 100% 90% 80% -60 -40 -20 0 20 40 60 Temperature (°C) Page 3 Document number: 1017119.2 maxwell.com 80 DATASHEET 56V MODULE NOTES 1. Capacitance and ESRDC measured at 25°C per Document Number 1007239 available at www.maxwell.com. 2. Per Maxwell Document 1007239 available at www.maxwell.com. ½ CV 3. Maximum Peak current (1 sec) = C x ESRDC + 1 4. After 72 hours at 25°C and rated voltage. Initial leakage current can be higher. 0.12V2 5. Per IEC 62391-2, Pd = ESR x mass DC V2 6. Pmax = 4 x ESRDC x mass 7. Emax = ½ CV2 3,600 x mass MOUNTING RECOMMENDATIONS Please refer to the user manual for installation recommendations. Page 4 Document number: 1017119.2 maxwell.com 8. Estored = ½ CV2 3,600 9. Cycle per Document Number 1007239 available at www.maxwell.com. 10. No more than 10% decrease in capacitance from minimum initial capacitance or 50% increase in ESR from maximum initial ESR. 11. Tested at 1 kV DC. 12. For a given application, sufficient cooling must be provided to keep cell case temperatures below 65°. See Rth. 13. Duration = 60 seconds. Not intended as an operating parameter. 14. Absolute maximum voltage non repeated, not to exceed 1 second. MARKINGS Products are marked with the following information: Rated capacitance, rated voltage, product number, name of manufacturer, positive and negative terminal, warning marking, serial number. 4 3 DATASHEET 2 1 56V MODULE D D BMOD0130 P056 B03 M10 NEGATIVE TERMINAL LEFT SIDE 312.8±2.0 M8 POSITIVE TERMINAL 20.0±1.0 TYP. 218.2 1.0 BMOD0130 P056 BO3 MONITOR CABLE ONLY, 150 MIN C C 175 MAX H T 74.9 2 BRASS INSERT FACE 100.0±2.0 B 135.0 1.0 22 5.1±1.0 218.2 1.0 RIGHT SIDE 17.0±2.0 149.1±2.0 70.6 1.0 L 683 MAX W 5.1±1.0 652.2±3.0 TYPICAL WIDTH FROM BRASS INSERT FACE A BRASS INSERT FACE Part Description BMOD0130 P056 B03 4 L (max) 683 BOTTOM 3 Dimensions (mm) W (max)164.3±1.5 H (max) 177 TYPICAL WIDTH FROM BRASS INSERT FACE 175 A T (±2mm) SIZE 2 CAGE CODE B 68911 SCALE 1:5 74.9 DOC. NO. Package Quantity 108880, 109358 REV PART NO. 2 REV 1017268 2 1 1 SHEET 2 OF 2 B-PG1 REV A 7/01 Product dimensions are for reference only unless otherwise identified. Product dimensions and specifications may change without notice. Please contact Maxwell Technologies directly for any technical specifications critical to application. All products featured on this datasheet are covered by the following U.S. patents and their respective foreign counterparts: 7027290, 7.352.558, 7.295.426, 7.090.946, 7.508.651, 7.492.571, 7.342.770, 6.643.119, 7.384.433, 7.147.674, 7.317.609, 7.495.349, 7.102.877. Maxwell Technologies, Inc. Global Headquarters 5271 Viewridge Court, Suite 100 San Diego, CA 92123 USA Tel: +1 858 503 3300 Fax: +1 858 503 3301 Page 5 B 32.2±2.0 177 MAX Maxwell Technologies SA CH-1728 Rossens Switzerland Tel: +41 (0)26 411 85 00 Fax: +41 (0)26 411 85 05 Document number: 1017119.2 maxwell.com Maxwell Technologies, GmbH Brucker Strasse 21 D-82205 Gilching Germany Tel: +49 (0)8105 24 16 16 Fax: +49 (0)8105 24 16 19 Maxwell Technologies, Inc. Shanghai Representative Office 13E, CR Times Square 500 Zhangyang Road, Pudong Shanghai 200122, P.R. China Tel: +86 21 5836 8780 Fax: +86 21 5836 8790